MACURCO CD-12 line voltage Gas Detector, controller and transducer for Carbon Dioxide (CO2) 0-5000ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

CD-12MC   
515.08

Voltage
Calibration

   2 Days  ]
4 Variants of base SKU

The Macurco 12-Series are line voltage (100-240VAC), dual relay gas detector, controller and transducers. The 12-Series utilizes an internal switching power supply that is capable of using line voltage between 100 and 240VAC and 50-60Hz. The 12-Series have selectable 4-20mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of various gases and provide feedback and automatic control to help reduce gas concentrations in parking garages, maintenance facilities or other commercial applications.

Selectable options include:
  • Selectable relay actuation levels
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Buzzer, digital display, latching relay, relay delay, relay minimum runtime
Features:
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Supervised system design: detector problem will cause relay activation
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
12-Series Rear View

Specifications:
Power: 100-240VAC (50 TO 60 HZ)
Current: 1.0 A MAX
Shipping Weight: 1 pound (0.45 kg)
Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Color: Dark gray
Connections: plugs/terminals
Mounting box: (not included) 4x4 electri
Fan relay: 5A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation: Selectable within sensor range
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Runtime settings OFF (default), 3, 5, 10 or 15 minutes
Alarm relay: 0.5A 120 V, 60 VA
Alarm relay actuation: selectable N.O. default or N.C.
Alarm relay settings: Selectable within sensor range
Current Loop 4-20 mA
Operating Environment: 0°F to 125° F (-18°C to 52°C).10 to 90% RH
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
Cal-Kit 4*CO2400PPM
(6838)

MACURCO  Cal-Kit 4*CO2400PPM

Macurco Cal-Kit 4 Carbon Dioxide (CO2) 400ppm / 5000ppm gas field calibration kit to calibrate Macurco CD fixed gas detectors. 17L. Includes Carry Case, Regulator, Tubing and calibration hood 2ft. 1/cs. 30-0041-1130-2.

Configure

$515.47 
RAD-0102-6
(7048)

CO2METER  RAD-0102-6

CO2Meter RAD-0102-6 Remote "CO2 Storage Safety 3" gas leak detector with local and remote displays for Carbon Dioxide (CO2) 0-5% (0-50,000 ppm) with NDIR sensor. Includes audible and visual alarms, 3 alarm relays, 4-20 mA output and LCD display. IP54 Enclosure. UL Listed, meets NFPA, IFC, and NBIC requirements, OSHA and NIOSH TWA standards. Alarms 5,000 TWA, 1.5% (user configurable), 3% (user configurable), sensor life > 15 years, 12-24VDC power, includes 110-220VAC multi-region power adapter.

Configure

$672.00 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
> CARBON DIOXIDE :    26 Items found.
XNXUTAVNNIC1
(2137)

HONEYWELL  XNXUTAVNNIC1

Honeywell XNX Universal Gas Detector Transmitter including MPD AMIC1 IR (infrared) CO2 Carbon Dioxide sensor 0-1%/0-5% Vol. Backlit LCD Display, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,276.97 
6400AL1-0-1032/015P
(7021)

RC SYSTEMS  6400AL1-0-1032/015P

RC Systems SenSmart 6400 3 wire Dual Channel Gas Detector for Carbon Dioxide (C02) 0-1.5% or 0-5% with 'ST-44' smart transmitter and GEN2 smart sensor. IR sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,603.89 
GD10-P00-23BC-0XH-00
(5114)

SIMTRONICS  GD10-P00-23BC-0XH-00

Simrad GD10P IR Point Gas Detector for Carbon Dioxide (CO2) with selectable ranges (3-100% vol) on offshore installations. 4-20 mA output with HART. 24 VDC. Available Approvals: UL Class I Division 1, ATEX, CSA/US, IECEx, INMETRO, ABS, SIL and MED.

GG2SAXXX-X-CO2
(5016)

ION SCIENCE  GG2SAXXX-X-CO2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Carbon dioxide (CO2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

3400MAL-0-0500/3V/L0
(7040)

RC SYSTEMS  3400MAL-0-0500/3V/L0

RC Systems SenSmart 3400M 3 wire gas detector for Carbon Dioxide (CO2) 0-3 %Vol or 0-5 %Vol with 'ST-48' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$4,518.18 
6400MAL-0-0500/3V/L0
(7042)

RC SYSTEMS  6400MAL-0-0500/3V/L0

RC Systems SenSmart 6400M 3 wire Dual Channel Gas Detector for Carbon Dioxide (CO2) 0-3 %Vol or 0-5 %Vol with 'ST-44' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$4,940.25 
Page: 1 | 2 | All