Macurco Cd-6mc | Carbon Dioxide | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   CD-6MC

MACURCO CD-6MC
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MACURCO CD-6 low voltage Carbon Dioxide (CO2) 0-5000ppm Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

CD-6MC   
495.09

Voltage
Modbus RS-485 Adapter
Calibration

   2 Days  ]
4 Variants of base SKU
Carbon Dioxide Detection and Control

The Macurco CD-6 is a low voltage, dual relay Carbon Dioxide (CO 2 ) detector, controller and transducer. The CD-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of Carbon Dioxide and provide feedback and automatic exhaust fan control to help maintain appropriate Carbon Dioxide concentrations in commercial applications. The CD-6 is a low level meter capable of detecting from 0-2000 ppm of Carbon Dioxide.

Selectable options include:
  • Fan relay actuation: selectable at 600, 700, 800, 900, 1000 (default), 1100, 1200, 1300, 1400, 1500 ppm
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Digital display (0-2000 ppm), buzzer, fan delay, fan minimum runtime
Installation
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT fan relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Factory calibrated
Other Features
  • Supervised system design: detector problem will cause the fan & alarm relay to activate
  • Self calibrating, optional gas test kit allows the CD-6 to be field tested
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
Location

A CD-6 is normally mounted at breathing level, about 5 feet (1.5 meters) above the floor on a wall or column in a central area where the air gets refreshed on a regular basis. The unit typically covers up to about 5,000 sq.ft. (465 square meters). The coverage depends on air movement within the room or facility. Additional detectors may be needed near any areas where people work or where the air is stagnant. The CD-6 mounts on a 4x4 electrical box supplied by the contractor. Do not install the CD-6 inside another box unless it has good air flow through it. Do NOT mount the CD-6 where the normal temperature is below 32°F or exceeds 122°F (below 0°C or above 50°C).

Macurco CM-6, GD-6 and TX-6 wiring terminals
Macurco CM-6, GD-6 and TX-6 side view

Specifications:
Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC
Current (normal) @ 24 VDC: 75 mA in alarm, 53 mA fan relay on and 30 mA stand by
Current (max) @ 24 VDC: 126 mA in alarm, 108 mA fan relay on and 85 mA stand by
Shipping Weight: 1 pound (0.45 kg)
Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Color: White
Connections: plugs/terminals
Mounting box: (not included) 4x4 electri
Alarm relay: 0.5A 120 V, 60 VA
Alarm relay actuation: selectable N.O. (default) or N.C.
Fan relay: 5A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation: selectable at “dIS” (disabled), 600, 700, 800, 900, 1000 (default), 1100, 1200, 1300, 1400 or 1500 ppm
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Relay Minimum Runtime settings 0 (default), 3, 5, 10 or 15 minutes
Operating Environment: 32°F to 122° F (0°C to 50°C),10 to 90% RH non-condensing
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    8 Items found.
MRS-485
(2947)

MACURCO  MRS-485

MACURCO Modbus RS-485 Slave Adapter for use with Macurco 6-Series gas leak detectors to convert the 4-20mA analog signal from Macurco 6-Series type detectors to a Modbus digital signal for use with multipoint addressable systems and control panels such as the DVP-120M. Plugs into the back of the detector.



$118.05 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
Cal-Kit 4*CO2400PPM
(6838)

MACURCO  Cal-Kit 4*CO2400PPM

Macurco Cal-Kit 4 Carbon Dioxide (CO2) 400ppm / 5000ppm gas field calibration kit to calibrate Macurco CD fixed gas detectors. 17L. Includes Carry Case, Regulator, Tubing and calibration hood 2ft. 1/cs. 30-0041-1130-2.

Configure

$515.47 
RAD-0102-6
(7048)

CO2METER  RAD-0102-6

CO2Meter RAD-0102-6 Remote "CO2 Storage Safety 3" gas leak detector with local and remote displays for Carbon Dioxide (CO2) 0-5% (0-50,000 ppm) with NDIR sensor. Includes audible and visual alarms, 3 alarm relays, 4-20 mA output and LCD display. IP54 Enclosure. UL Listed, meets NFPA, IFC, and NBIC requirements, OSHA and NIOSH TWA standards. Alarms 5,000 TWA, 1.5% (user configurable), 3% (user configurable), sensor life > 15 years, 12-24VDC power, includes 110-220VAC multi-region power adapter.

Configure

$672.00 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
DVP-120M
(3973)

MACURCO  DVP-120M

Macurco DVP-120M Addressable Detection and Ventilation Panel. Modbus-Enabled with up to 87 Modbus RS-485 addressable sensors on three channels of 29 sensors per channel. Features 12 4-20mA sensor inputs (for a total of 99 channels) , three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,444.88 
> CARBON DIOXIDE :    26 Items found.
XNXUTAVNNIC1
(2137)

HONEYWELL  XNXUTAVNNIC1

Honeywell XNX Universal Gas Detector Transmitter including MPD AMIC1 IR (infrared) CO2 Carbon Dioxide sensor 0-1%/0-5% Vol. Backlit LCD Display, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,276.97 
6400AL1-0-1032/015P
(7021)

RC SYSTEMS  6400AL1-0-1032/015P

RC Systems SenSmart 6400 3 wire Dual Channel Gas Detector for Carbon Dioxide (C02) 0-1.5% or 0-5% with 'ST-44' smart transmitter and GEN2 smart sensor. IR sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,603.89 
GD10-P00-23BC-0XH-00
(5114)

SIMTRONICS  GD10-P00-23BC-0XH-00

Simrad GD10P IR Point Gas Detector for Carbon Dioxide (CO2) with selectable ranges (3-100% vol) on offshore installations. 4-20 mA output with HART. 24 VDC. Available Approvals: UL Class I Division 1, ATEX, CSA/US, IECEx, INMETRO, ABS, SIL and MED.

GG2SAXXX-X-CO2
(5016)

ION SCIENCE  GG2SAXXX-X-CO2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Carbon dioxide (CO2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

3400MAL-0-0500/3V/L0
(7040)

RC SYSTEMS  3400MAL-0-0500/3V/L0

RC Systems SenSmart 3400M 3 wire gas detector for Carbon Dioxide (CO2) 0-3 %Vol or 0-5 %Vol with 'ST-48' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$4,518.18 
6400MAL-0-0500/3V/L0
(7042)

RC SYSTEMS  6400MAL-0-0500/3V/L0

RC Systems SenSmart 6400M 3 wire Dual Channel Gas Detector for Carbon Dioxide (CO2) 0-3 %Vol or 0-5 %Vol with 'ST-44' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$4,940.25 