Macurco Ox-12 | Oxygen | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   OX-12

MACURCO OX-12
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MACURCO OX-12 line voltage Gas Detector, controller and transducer for Oxygen (O2) 0-25% vol. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

OX-12   
494.01

Voltage
Housing Color

   2 Days  ]
2 Variants of base SKU

The Macurco 12-Series are line voltage (100-240VAC), dual relay gas detector, controller and transducers. The 12-Series utilizes an internal switching power supply that is capable of using line voltage between 100 and 240VAC and 50-60Hz. The 12-Series have selectable 4-20mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of various gases and provide feedback and automatic control to help reduce gas concentrations in parking garages, maintenance facilities or other commercial applications.

Selectable options include:
  • Selectable relay actuation levels
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Buzzer, digital display, latching relay, relay delay, relay minimum runtime
Features:
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Supervised system design: detector problem will cause relay activation
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
12-Series Rear View

Specifications:
Power: 100-240VAC (50 TO 60 HZ)
Current: 1.0 A MAX
Shipping Weight: 1 pound (0.45 kg)
Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Color: Dark gray
Connections: plugs/terminals
Mounting box: (not included) 4x4 electri
Fan relay: 5A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation: Selectable within sensor range
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Runtime settings OFF (default), 3, 5, 10 or 15 minutes
Alarm relay: 0.5A 120 V, 60 VA
Alarm relay actuation: selectable N.O. default or N.C.
Alarm relay settings: Selectable within sensor range
Current Loop 4-20 mA
Operating Environment: 0°F to 125° F (-18°C to 52°C).10 to 90% RH
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
CX/TX-CH
(2117)

MACURCO  CX/TX-CH

MACURCO Calibration Hood/cup for CX, TX, OX, & RD series gas detectors: ammonia (NH3), hydrogen sulfide (H2S) and Nitrogen Dioxide (NO2).



$33.38 
70-2900-0605-2
(6328)

MACURCO  70-2900-0605-2

MACURCO OX-6 (OX-12) Oxygen O2 Replacement sensor. (Replaces 26-1017-4969-0)

Configure

$93.65 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
Cal-Kit 1*O2 GAS17
(6839)

MACURCO  Cal-Kit 1*O2 GAS17

Macurco Cal-Kit 1 Oxygen (O2) 17% / Zero Air 20.9% gas field calibration kit to calibrate Macurco gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood 2ft. 1/cs. 30-0021-1110-2.

Configure

$468.23 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
> OXYGEN :    29 Items found.
51001AL-0-1010/25V/L0
(7131)

RC SYSTEMS  51001AL-0-1010/25V/L0

RC Systems SenSmart 5100 3-wire gas detector for Oxygen (O2) 0-25% vol. with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
967-343490-25P
(6065)

DETCON  967-343490-25P

Detcon DM-700-O2 Electrochemical Smart Oxygen (O2) 0-25% Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNO2
(5108)

HONEYWELL  SPXCDULNO2

Honeywell Sensepoint XCD RTD Gas Detector for Oxygen (O2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 25% v/v. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
961-340026-025G
(6372)

DETCON  961-340026-025G

Detcon DM-100-O2 Electrochemical Oxygen (O2) 0-25%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2100AL-0-9010/25V/L0
(116)

RC SYSTEMS  2100AL-0-9010/25V/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
31001AL-0-9010/25V/L0
(5787)

RC SYSTEMS  31001AL-0-9010/25V/L0

RC Systems SenSmart 3100 3 wire gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
XNXUTAENNNNN-XNXXSO1SS
(849)

HONEYWELL  XNXUTAENNNNN-XNXXSO1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Oxygen (O2) 0-25%VOL compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$1,969.63 
6100AL1-0-1010/0025P
(7013)

RC SYSTEMS  6100AL1-0-1010/0025P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Oxygen (O2) 0-25% vol with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
GG2SAXXX-X-O2
(5019)

ION SCIENCE  GG2SAXXX-X-O2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Oxygen (O2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.