Simrad GD10PE IR Extended Point Gas Detector for Methane (CH4) 0-20% LEL for offshore installations. 4-20 mA output with HART. 24 VDC. IP66 and IP67. Available Approvals: UL Class I Division 1, ATEX, CSA, IECEx, INMETRO and SIL.

GD10-PE0-17DE-0XH-00   
Please Email us your request for quote   

Approval
Interface
Weather protection
Duct Mount

   4 Weeks  ]
6 Variants of base SKU

The GD10PE is designed for critical applications involving large volumes of air with high velocity. In places where you need fast reliable detection of low gas concentrations. GD10PE is in a class of its own.

The versatile GD10PE is suitable for monitoring, among others, the HVAC air intakes of living quarters, temporary refuges and local equipment rooms. In addition the ventilation air and combustion air intakes of gas turbines can be monitored along with the ventilation air extract duct, the only location where you can guarantee to detect a gas leak on a turbine package.

With a measuring range of 0-20% LEL the GD10PE is 5 times more sensitive than standard point detectors.

The GD10 range of infrared gas detectors differ from all other models, because they utilise silicon based solid-state infrared sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.

An industry standard HART® interface is used for configuration of the leve

Features

  • Solid state IR sources [SimSourceTM]
  • High IR source flash rate
  • True dual path, double compensation optical design
  • 5x more sensitive than conventional point detectors
  • Dual layer weather protector
  • Early dirty optics warning
  • Independently heated mirror and lens
  • Continuous operation at 85°C
Benefits

  • Superior long term performance compared to filament lamps
  • Improved stability and speed of response
  • No recalibration, monitors and accounts for all changes in optical path
  • Suitable for critical applications requiring early detection
  • No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand
  • Improved preventative maintenance
  • High performance detection in rough environmental condition
  • Suitable for gas turbine ventilation extract ducts

GD10PE SPECIFICATIONS
GENERAL
Detection method IR-absorption, dual wavelength, dual path
IR-Source Solid state IR source, 50Hz flash
Detection range 0-20% LEL (0-1 % Vol.) methane
Gases detected Hydrocarbons
Self-test Continuous
Calibration Factory set, no field recalibration
PERFORMANCE
Lifetime stability *) ±1 .4%LEL
Accuracy *) ±1 %LEL (0-1 0 % LEL reading)
±1 .4%LEL (1 0-20 %LEL reading)
Response time
Detector reading:1 00%LEL test gas:20%LEL test gas:
4% LEL0.6 sec.1 sec.
10% LEL0.9 sec.2.5 sec.
18% LEL1.3 sec.6 sec.
Start-up time *) Less than 60 sec.
  *) Ref: -20°C to + 60°C (-4°F to +1 40°F)
OUTPUT SIGNAL
Standard Current source 4 - 20 mA, max. load impedance 500 Ohm
Option Current sink 4 - 20 mA
HART® Maintenance and configuration
Detector warnings:
- Early clean optics
- Dirty optics
- Detector failure
Configurable (HART)
Pre warning (2 mA)
Dirt accumulation (1 mA)
Internal fault (0 mA)
ELECTRICAL
Power supply 24 VDC, range 18-32 VDC
Power consumption Approx. 3.5 W
Connection 3 wires [0.5mm2 - 1.5mm2)
(12 AWG - 22 AWG)
Cable entry M20 EExe cable gland
TEMPERATURE RANGE
Storage -40°C to + 70°C (-40°F to + 158°F)
Operating -40°C to + 65°C (-40°F to + 149°F)
Probe, inside duct up to +85°C (1 85°F)
Humidity (operation) 100% RH
EXPLOSION PROOF HOUSING
Main compartment EExd IIC T6
Terminal cornp. EExe
Protection category IP66/IP67 DIN 40050
Housing material Stainless steel 5152343 (ASTM 316)
Dimensions 1 04W x 1 05D (mm);
30.9 x 4.1 x 4.1 (inches) Overall
Weight (detector) Approx. 6.5 kg (14.3 lbs)
Weather protection Approx. 0.3 kg (0.7 Ibs)
Duct mount kit Approx. 2.1 kg (4.6 Ibs)
WARRANTY
5 years full warranty on complete instrument
1 5 years warranty on the IR-sources
APPROVALS
UL CLASS I DIVISION 1 GROUPS C-D
ATEX 07ATEX1438
CSA 1773527
IECEx NEM 07.0006
INMETRO AEX-11698
SIL Qualified for SIL2 and SIL3 systems
VERSIONS
Gas Ranges
Methane 0-20%LEL
Ethylene 5,000 PPM
Other versions are available, please contact your dealer.
ACCESSORIES
Weather protection Required for standard installation
Sample flow housing For sampling systems and testing
Duct mount kit Through wall installation
WARRANTY
5 years full warranty on complete instrument
15 years warranty on the IR-sources
Export Info
Made inFrance
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> LEL INFRARED :    24 Items found.
XNXUTAINNNNN-2108N4110
(851)

HONEYWELL  XNXUTAINNNNN-2108N4110

Honeywell XNX Universal Gas Detector Transmitter with Optima Plus Infrared Hydrocarbon Gas Detector combustible 0-100% LEL (Lower Explosive Limit) and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2 . Available for over 100 gas and vapour calibrations.

Configure

$3,478.59 
2108N5110N
(1966)

HONEYWELL  2108N5110N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for gas ranges 0–100 %v/v Methane (CH4), 0–600,000 ppm Propane (C3H8) and 0–400,000 ppm Propane (C3H8). 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration fitted with remote gassing cell and flow housing.

Configure

$3,571.00 
3300MAL-0-0498/100L/L0
(7039)

RC SYSTEMS  3300MAL-0-0498/100L/L0

RC Systems SenSmart 3300M 3 wire gas detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-48' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof). Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,518.18 
6300MAL-0-0498/100L/L0
(7041)

RC SYSTEMS  6300MAL-0-0498/100L/L0

RC Systems SenSmart 6300M 3 wire Dual Channel Gas Detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-44' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66. Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,940.25 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.