Intec Controls PolyGard SPC3-1195 Sigle-Point Gas Detector for Oxygen (O2) 0-25% Vol, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. *** Phased Out ***

Inquiry

APPLICATION

To detect and control levels of oxygen (O2) and other gases in a wide variety of commercial and industrial applications such as the Oxygen level in unoccupied mechanical or chiller rooms, laboratories, food production areas and ventilation systems, etc. The controller can communicate with any compatible electronic analog control, DDC/PLC control or automation system via binary and/or analog output signal.

FEATURES
  • Continuous monitoring
  • One (1) built-in O2 electrochemical sensor
  • Easy plug-in sensor
  • One (1) remote analog input, 4-20 mA
  • One (1) digital input
  • Two (2) relay outputs:
    Four stage control
    Fail-safe assignable
  • One (1) analog output, (0)4-20 mA / (0)2-10 VDC - Selectable for low, high, or averaging
  • One (1) 24 VDC switched output
  • Liquid Crystal Display (LCD)
  • LED status indicators
  • Accepts toxic or combustible gas, refrigerant, temperature or humidity secondary remote sensor input
  • Built-in horn
  • Keypad user interface
  • Simple menu-driven programming
  • Modular technology
  • Overload & short-circuit protected
  • NEMA 4X enclosure
  • Easy maintenance

Specifications
Electric
Power supply 24 VAC/VDC, -20%/+15% 50/60 Hz, reverse polarity protected
Power consumption 5 VA (0.2 A) w/ (1) remote sensor connected
Sensor Performance
Gas detected Oxygen (O2)
Sensor element Electrochemical, diffusion
Range 0-25 %, air by volume
Accuracy & Resolution 0.1 %
Repeatability < 0.1 % of reading
Long term output drift < 4% of reading / year
Response time t90 < 15 sec.
Sensor life expectancy 2 years, normal operating environment
Sensor coverage 2,500 sq. ft., max 5,000 sq. ft. (232 m 2 , max 464 m 2 ), under “ideal conditions”
Installation Location
Mounting height 5 to 6 ft. (1.5-1.8 m) above floor
Type of Control
General Four-stage (S1 to S4) control, assignable up to two (2) binary/ relay, horn/audible alarm, and 24 VDC / 50 mA switched outputs, i.e. low-high stage for relay output, horn / audible alarm and switched 24 VDC at any stage for remote alarming
Analog input One (1) 4-20 mA, for additional remote sensor, load < 55 mA / 200 Ω, reverse polarity protected
Analog reading Current and mean (average) value
Stage level / setpoint Field adjustable over full range, four (4) stages (S1 to S4) per analog input, assignable to current or mean (average) value
- hysteresis/ switching differential Selectable for each sensor point
Digital input One (1); can be assigned to any relay (R1, R2)
- application Remote audio/visual alarm reset or override function
Type of Control (cont...)
Relay outputs (R1, R2) w/ status LEDs (1) SPDT (R1), and (1) SPST-NC or SPST-NO (R2), jumper selectable
Contact rating
-each stage level (S1-S4)
-sensor fail-safe
30 VAC/VDC, 0.5 A, max.
Assignable to any relay
Assignable to any stage level
Time delay switching Selectable for make and brake of each sensor point (SP1 to SP2) 0‐9,999 seconds
Analog output One (1), (0)4‐20 mA, load < 500 Ω;(0)2-10 VDC, load > 50K Ω; jumper selectable; polarity protected, assignable to low, high or averaging of sensor inputs
VDC switched output One (1) 24 VDC, 50 mA max
Audible alarm 83 db @ unit, enabled or disabled, selectable; assignable to stage level S1, S2, S3 or S4
Alarm acknowledgment Menu-driven and system reset function for latched relays
User Interface
Keypad type Refer to illustration “Keypad User Interface”
Touch buttons Four (4)
Status LED’s Four (4), for system on, stage status, and failure
Digital display Liquid Crystal Display (LCD), two lines, 16 characters per line, 1 digit resolution
-unit display Menu selectable, per sensor; ppm, %v/v, %LEL, °F or %RH
Environmental
Permissible ambient
-working temperature 14°F to 122°F (-10°C to 50°C)
-storage temperature 23°F to 86°F (-5°C to 30°C)
-humidity 15 to 95% RH, non-condensing
-working pressure Atmospheric ± 10%
Physical
Enclosure (panel)
-material Polycarbonate, UL 94-HB, fire-retardant
-conformity UL 50 standards
-color Light gray
-protection NEMA 4X (IP65)
-installation Wall (surface) mounted, or single gang electrical box
Dimensions (H x W x D) 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)
Cable entry 3 holes for 1/2 in. conduit for wall (surface) mounting and 1 hole on back side of base plate for single gang electrical box mounting
Wire connection Terminal blocks, screw type for lead wire
Wire size Min. 24 AWG (0.25 mm 2 )
Max 14 AWG (2.5 mm 2 )
Wire distance Max. loop resistance 450 Ω (= wire distance plus controller input resistance)
Weight 0.6 lb. (0.3 kg)
Approvals / Listings
-unit rating NRTL Certification to STD
ANSI/UL 61010-1
CE
EMV-Compliance 2004/108/EWG
Low voltage directive 73/23/EWG
-relays (R1-R2) UL Recognized, E41515
CSA, C22.2 No. 0, No. 14 (File No. LR31928)
-enclosure UL Listed, E208470
CSA Certified, E208470
Warranty Two years material and workmanship, 12 months normal exposure for sensor element
> OXYGEN :    30 Items found.
41001AL-0-1010/0025P/L0
(7176)

RC SYSTEMS  41001AL-0-1010/0025P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Oxygen (O2) 0-25% vol with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1010/25V/L0
(7131)

RC SYSTEMS  51001AL-0-1010/25V/L0

RC Systems SenSmart 5100 3-wire gas detector for Oxygen (O2) 0-25% vol. with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
967-343490-25P
(6065)

DETCON  967-343490-25P

Detcon DM-700-O2 Electrochemical Smart Oxygen (O2) 0-25% Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNO2
(5108)

HONEYWELL  SPXCDULNO2

Honeywell Sensepoint XCD RTD Gas Detector for Oxygen (O2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 25% v/v. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
961-340026-025G
(6372)

DETCON  961-340026-025G

Detcon DM-100-O2 Electrochemical Oxygen (O2) 0-25%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2100AL-0-9010/25V/L0
(116)

RC SYSTEMS  2100AL-0-9010/25V/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
31001AL-0-9010/25V/L0
(5787)

RC SYSTEMS  31001AL-0-9010/25V/L0

RC Systems SenSmart 3100 3 wire gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
XNXUTAENNNNN-XNXXSO1SS
(849)

HONEYWELL  XNXUTAENNNNN-XNXXSO1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Oxygen (O2) 0-25%VOL compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$1,969.63 
6100AL1-0-1010/0025P
(7013)

RC SYSTEMS  6100AL1-0-1010/0025P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Oxygen (O2) 0-25% vol with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
GG2SAXXX-X-O2
(5019)

ION SCIENCE  GG2SAXXX-X-O2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Oxygen (O2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

Page: 1 | 2 | All