Simrad GD10P IR Point Gas Detector for combustible gases: Methane (CH4) , Ethylene (C2H4), Propane (C3H8), Acetylene, Butane and others on offshore installations. 4-20 mA output with HART. 24 VDC. Available Approvals: UL Class I Division 1, ATEX, CSA/US, IECEx, INMETRO, ABS, SIL and MED.

GD10-P00-17DG-0BH   
Please Email us your request for quote   

Target Gas
Approval
Interface
Weather protection
Sample Flow
Duct mounting kit
Mosquito Set
Sunshade Assembly

   In Stock  ]

Standard configurations typically available in In Stock:
GD10-P00-17DG-0BH    GD10-P00-17DG-0BH-00
108 Variants of base SKU / 30 Shown below

The Simrad GD10P detector is the benchmark for combustible gas detection on offshore installations. It has set the standard for gas detectors in the areas of safety, stability and low maintenance. GD1OP comes with 5 years warranty.

The GD1OPhas been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations.

These infrared gas detectors differ from all other models, because they utilise silicon based solid-state infrared sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.

We offer the longest combined detector and IR source warranty on the market.

For retrofit applications, a bridge interface is available allowing the detector to be connected directly to catalytic systems, using the existing cabling and control modules.

Supplied with worldwide performance and hazardous area approvals. Suitable for use in SIL 2 systems.

An industry standard HART interface is used for configuration of the optional fast response time and special fault levels as well as access to extended maintenance data.

Features

  • Solid state IR sources [SimSourceTM]
  • High IR source flash rate
  • True dual path, double compensation optical design
  • Selectable response rate
  • Dual layer weather protector
  • Early dirty optics warning
  • Improved preventative maintenance
  • Integral termination compartment
  • Low power consumption
  • Independently heated mirror and lens
Benefits

  • Superior long term performance compared to filament lamps
  • Improved stability and speed of response
  • No recalibration, monitors and accounts for all changes in optical path
  • Fastest IR point detector on the market, ideal for speed critical applications
  • No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand
  • Reduced installation time, the unit is ready out of the box
  • Reduces load on UPS
  • High performance detection in rough environmental condition

GD SPECIFICATIONS
GENERAL
Detection method IR-absorption, dual wavelength, dual path
IR-Source Solid state IR source, 50Hz flash
Gases detected Hydrocarbons, see separate data sheet
for C02 detection
Self-test Continuous
Calibration Factory set, no field recalibration
Configuration HART (response time, fault levels)
PERFORMANCE
Lifetime stability *) ±5% of full scale (FS) reading
Accuracy *) ±3% FS between 0-50 % reading
±5% FS between 50-100 % reading
Response time T20 = 1 sec. (0.3 sec)
Configurable T50 = 2.5 sec. (0.7 sec)
T90 = 6 sec. (1.6 sec)
Start-up time *) Less than 60 sec .
  *) Refers to -20°C to + 45°C
OUTPUT SIGNAL
Standard Current source 4 - 20 mA, max. load impedance 500 Ohm
Option Current sink 4 - 20 mA
HART® Maintenance and configuration
Detector warnings:
- Early clean optics
- Dirty optics
- Detector failure
Configurable (HART)
Pre warning (2 mA)
Dirt accumulation (1 mA)
Internal fault (0 mA)
ELECTRICAL
Power supply 24 VDC, range18-32 VDC
Power consumption Approx. 3.5 W
Connection 3 wires [0.5mm2 - 1.5mm2)
Cable entry M20 EExe cable gland
TEMPERATURE RANGE
Storage -40°C to + 70°C (-40°F to + 158°F)
Operating -40°C to + 65°C (-40°F to + 149°F)
Humidity (operation) 100% RH
EXPLOSION PROOF HOUSING
Main compartment EExd IIC T6
Terminal cornp. EExe
Protection category IP66/IP67 DIN 40050
Housing material Stainless steel 5152343 (ASTM 316)
Weight Approx. 2.9 kg (6.4 lbs)
Dimensions 264L x 104W x 106H (mm)
10.4 x 4.1 x 4.2 (inches)
APPROVALS
UL CLASS I DIVISION 1 GROUPS C-D
ATEX 07ATEX1438
CSA 1773527 (100 % LEL Methane)
IECEx NEM 07.006
INMETRO AEX-11698
ABS # 04-LD444057-PDA
SIL Qualified for SIL2 systems
MED B - 5901
VERSIONS
Methane 0-100 %LEL, 0-100 %Vol
Propane 0-100 %LEL
Other versions are available, please contact your dealer
FRONT COVER
Required, select one  
- Weather protection
- Sample flow housing
- Duct mount kit

For standard point detector
For sampling systems and testing
For through wall installation
ACCESSORIES
Mosquito net Extra insect protection
Sun shade Shielding for extreme radiation exposure
WARRANTY
5 years full warranty on complete instrument
15 years warranty on the IR-sources
Export Info
Made inFrance
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
599-904176
(1869)

SIMTRONICS  599-904176

Cap, cover for the gas test nozzle for Simrad GD10P. Calibration test cup.



 
100-12P0.5
(3456)

PORTAGAS  100-12P0.5

Portagas 100 Series 58DS, 103DS, 58DAL, 58 Liter GAL, 34DAL 100-12P Preset Flow Regulator for Portagreen, DAL and DS (disposable aluminum and steel) cylinders (preset flow) 3/16" hose barb, C-10 male fitting ( 5/8"-18UNF)

Configure

$116.20 
140-816580
(5810)

SIMTRONICS  140-816580

Simtronics Hand Held Terminal for GD10P Gas Detector



 
> LEL INFRARED :    24 Items found.
2108N5110N
(1966)

HONEYWELL  2108N5110N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for gas ranges 0–100 %v/v Methane (CH4), 0–600,000 ppm Propane (C3H8) and 0–400,000 ppm Propane (C3H8). 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration fitted with remote gassing cell and flow housing.

Configure

$3,571.00 
3300MAL-0-0498/100L/L0
(7039)

RC SYSTEMS  3300MAL-0-0498/100L/L0

RC Systems SenSmart 3300M 3 wire gas detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-48' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof). Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,518.18 
6300MAL-0-0498/100L/L0
(7041)

RC SYSTEMS  6300MAL-0-0498/100L/L0

RC Systems SenSmart 6300M 3 wire Dual Channel Gas Detector for Hydrocarbons 0-100% LEL or %Vol with 'ST-44' smart transmitter with high performance harsh environment infrared smart Millenium sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66. Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$4,940.25 
GD10-PE0-17DE-0XH-00
(3083)

SIMTRONICS  GD10-PE0-17DE-0XH-00

Simrad GD10PE IR Extended Point Gas Detector for Methane (CH4) 0-20% LEL for offshore installations. 4-20 mA output with HART. 24 VDC. IP66 and IP67. Available Approvals: UL Class I Division 1, ATEX, CSA, IECEx, INMETRO and SIL.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.