Honeywell 2106b1413 | Ammonia | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   2106B1413

HONEYWELL 2106B1413
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

2106B1413   
1,217.33

Certification/Entry Size
Gas Range
Weather housing
Terminal Housing
Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved

   4 Weeks  ]
9 Variants of base SKU

The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Ex d or Ex e approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics’ controllers or 3rd party DCS/ PLC systems. Both flammable and toxic versions are certified to the latest ATEX/ IECEx safety and performance standards.

The flammable detector is available in either % LEL or PPM detection range versions and provides an industry standard mV bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one.

The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Ex d, while front end Intrinsic Safety (IS) design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of ‘sticky’ gases such as Chlorine and Ammonia.

Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.

Fit For Purpose
  • Flammable, toxic and Oxygen versions available
  • High performance, low cost
  • Suitable for new and retro fit applications
Proven Sensor Technology
  • SurecellTM electrochemical sensors
  • Poison resistant catalytic bead
  • Fast and reliable
  • Typical 2 to 5 years operational life
ATEX/IECEx Certified
  • Complies with the latest standards
  • Hazardous area approval and performance
  • IP65/67 for use in harsh environments
  • Easy to Use
  • Factory set operation
  • Simple to replace
  • Minimal training required
Range of Accessories
  • Weatherproof cap
  • Flow adaptor
  • Duct mounting kit
  • Collecting cone

Installation Details

Dimensions

Sensepoint Dimensions

Sensepoint flammable and toxic gas detectors are installed using suitable Ex d or Ex e junction boxes. The standard junction box available from Honeywell Analytics includes an earth continuity plate for added RFI protection. The detectors have a choice of mounting thread size to match local preferences.

The Sensepoint range of flammable and toxic detectors are designed for use with a wide range of controllers available from Honeywell Analytics or with 3rd party control equipment accepting their industry standard output signals.

Electrical Connections

Sensepoint Electrical Connections

Ammonia (NH3) 50/1000ppm
Operating Temp -20 to +40˚C
Operating HumidityContinuous: 20 to 90% RH (non-condensing). Intermittent: 10 to 99% RH (non-condensing)
Storage Conditions0 to 25˚C; 30 to 70% RH
Operating Pressure90 to 110kPa
Warm-up Time < 3 minutes
Response Time
T20 -
T50 < 10 secs
T90 < 65 secs
Supply18 to 30VDC; 0.9W maximum
Signal OutputLoop powered 4-20mA
Linearity< 5% fsd
Operating Life18 months (typical)
Storage Life6 months.
Stability (zero)
with time* < ±2% fsd / yr
with temperature** < ±6% fsd
with humidity < ±10% fsd
Stability (span)
with time* < ±20% fsd / yr
with temperature*** < ±20% fsd
with humidity < ±10% fsd
Weight185g
Construc. MaterialsPolyphenylene Sulphide (PPS)
I.P. (NEMA) RatingIP65 (standard), IP67 (with weather protection fitted)
Certification Details
(ATEX/ IECEx)
II 2 GD Ex d ia IIC T4 Gb Tamb -40ºC to +65ºC
tb IIIC A21 IP67 T135ºC Db
Baseefa08ATEX0263X
IECEx BAS08.0070X
Other CertificationsRussian: GOST
Applicable StandardsThis product complies with the relevant CE standards including: EMC to EN50270, Flammable sensor to EN60079-29-1

* = % of range (fsd) per year
** Over operating temperature range
*** = % of applied concentration

Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
02000-A-1635
(1470)

HONEYWELL  02000-A-1635

Honeywell Weather Protection Housing with calibration port / calibration cup for XNX MPD sensors



$110.94 
00780-A-0100
(1560)

HONEYWELL  00780-A-0100

Sensepoint Terminal Housing - Bartec DE1155 With Continuity Plate 1 X 25mm - 3 X 20mm Entries -ATEX Approved



$181.44 
SCOTT-077-0207-EQUIV
(2430)

PORTAGAS  SCOTT-077-0207-EQUIV

Calibration Gas Ammonia 500ppm Balance Nitrogen Size 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas)

Configure

$252.43 
CYL-10005500
(1268)

PORTAGAS  CYL-10005500

Calibration Gas Ammonia (NH3) 100 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$252.43 
> AMMONIA :    42 Items found.
ECFX-200-N
(6467)

HONEYWELL  ECFX-200-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-200 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,596.46 
LBW-420-1-SS
(912)

COOL AIR  LBW-420-1-SS

Cool Air LBW-420 Ammonia (NH3) 0-100/1000ppm Gas Leak Detector 4-20mA analog output. NEMA 4X enclosure. Alarm, pre-alarm and auxiliary relays. 115/230 VAC, 50/60 Hz, or 24 VDC. User Adjustable ranges: 0-100, 0-250, 0-500 and 0-1000ppm

Configure

$1,631.80 
ECFX-1000-N
(6587)

HONEYWELL  ECFX-1000-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-1000 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,654.94 
LBW-420-LEL-DC-01
(6055)

COOL AIR  LBW-420-LEL-DC-01

Cool Air LBW-420-LEL Ammonia (NH3) 0-9.9% Gas Leak Detector. Includes 4-20mA analog output, 3 latching relays and LED Display. 18-36 VDC (Optional AC). NEMA 4X and UL listed enclosure.

Configure

$1,676.90 
ECFX-500-N
(6468)

HONEYWELL  ECFX-500-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-500 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

2100AL-0-9012/0300P/L0
(132)

RC SYSTEMS  2100AL-0-9012/0300P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,789.61 
LBW-HHS-II
(1556)

COOL AIR  LBW-HHS-II

Cool Air LBW-HHS-II Portable Handheld Ammonia (NH3) Leak Detector. Glass Filled Polycarbonate Housing. Includes touch-sensitive LCD display, 3 concentration alarms (caution, warning and danger), USB output, RS-232 Output Cable, 4GB of internal memory and rechargeable NiMH battery.

Configure

$1,820.40 
VL-F7-NH3-N4-LPA-NO
(3720)

HONEYWELL  VL-F7-NH3-N4-LPA-NO

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp.



 
S3KUL2-XNXXSA1SS
(685)

HONEYWELL  S3KUL2-XNXXSA1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring AMMONIA (NH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-200ppm, 0-1000ppm. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,837.05 
GG-NH3-2-EXP
(4149)

CALIBRATION TECHNOLOGIES  GG-NH3-2-EXP

CTI GasGuard NH3-2%-EXP Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressorrooms where E-stop or electrical shunt trip is desired. Explosion-proof. Enclosure and sensor head certified for hazardous locations. Industry standard linear 4-20 mA output. Power: 24 VDC, 120 mA. NEC, UL, CSA, FM and IEC Approvals.

Configure

$1,842.00 
961-500026-100G
(6349)

DETCON  961-500026-100G

Detcon DM-102-NH3 Electrochemical Ammonia (NH3) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ECFX-250-N
(6588)

HONEYWELL  ECFX-250-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-250 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
ECFX-100-N
(1516)

HONEYWELL  ECFX-100-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-100 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
SPXCDULNA2
(1897)

HONEYWELL  SPXCDULNA2

Honeywell Sensepoint XCD RTD Gas Detector for Ammonia (NH3) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9012/0300P/L0
(6888)

RC SYSTEMS  31001AL-0-9012/0300P/L0

RC Systems SenSmart 3100 3 wire gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,967.53 
967-505090-100
(6070)

DETCON  967-505090-100

Detcon DM-702-NH3 Electrochemical Smart Ammonia (NH3) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

VL-F7-NH3-N4-LPA-MK
(3716)

HONEYWELL  VL-F7-NH3-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). continuous monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2" cast steel T. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
XNXUTAENNNNN-XNXXSA1SS
(835)

HONEYWELL  XNXUTAENNNNN-XNXXSA1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Ammonia (NH3) compatible with all Honeywell gas sensing technologies, with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-200ppm, 0-1000ppm

Configure

$2,251.86 
IR-F9-NH3-0/2-N1
(1548)

HONEYWELL  IR-F9-NH3-0/2-N1

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Ammonia (NH3) 0-20000 ppm with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

6100AL1-0-1015/0100P
(7001)

RC SYSTEMS  6100AL1-0-1015/0100P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ammonia (NH3) 0-100 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.