Gds Gmii-03-020-05/00-000-00/0-0 | Ammonia | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GMII-03-020-05/00-000-00/0-0

GDS GMII-03-020-05/00-000-00/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ammonia (NH3) with range 0-50 to 0-1000 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Inquiry

The GASMAX II gas monitor delivers the latest in toxic & combustible gas detection technology, reliability and ease of use.

Widest Variety of Available Sensors

Built-in dual channel electronics allow the GASMAX II to support any GDS Corp sensor or any combination of one toxic and one combustible (bridge-type) sensor. GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX II constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible backlit display and high intensity alarm LEDs constantly show alarm status, calibrated engineering values and programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Flexible Output Options

In addition to standard dual 4-20mA current loop outputs, an optional dual isolated 4-20mA output board or an RS-485 two-wire MODBUS® interface with three 5A SPDT relays are available to communicate with controllers or drive local alarm indicators. When used with the C1 Protector controller’s MODBUS master port, multiple GASMAX II monitors can be daisy-chained up to 500m to minimize wiring.

Reliable

Available in both single and dual channel models, the GASMAX II is CSA and ATEX certified for use in Class I, Div 1 explosion proof installations. For low temperature applications, an Arctic Monitor option add thermostatically controlled heaters to enable operation as low as –55°C ambient.

FEATURES

  • CSA Certified for Class I, Div 1 explosion-proof installations
  • Monitor both toxic sensors and LEL with one detector
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Backlit display for better visibility in low light conditions
  • Options for 3x 5A alarm contacts, isolated 4-20mA and MODBUS®
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand

GASMAX II SPECIFICATIONS
Power Input: 10-30VDC at < 3 watts with relay board. Additional power (4W peak) required for Arctic Monitor option.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and eunits.
Electrochemical Sensor Input Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors
Bridge Type Sensor Input Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead. Can be converted to 4-20mA input for use with GDS-49 or other standard 4-20mA source.
Standard Output Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Output #1 Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC.
Optional Output #2 Three Form C Relays 5A @ 30VDC / 240VAC plus RS-485 2-wire MODBUS® slave interface
Temp -25°C to +65°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel opt
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP nstallations
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty 2 years from date of purchase on electronics and one year on sensors.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
10-0203
(259)

GDS  10-0203

GDS Sensor calibration cup for stainless steel / aluminum sensor heads



 
1200-0280
(3155)

GDS  1200-0280

GDS Gas Detector Calibration Gas Cylinder Ammonia (NH3) 300ppm. Balance Air. 58L Aluminium Cylinder.

1200-0260
(3154)

GDS  1200-0260

GDS Gas Detector Calibration Gas Cylinder Ammonia (NH3) 50ppm. Balance Air. 58L Aluminium Cylinder.

10-9520-R05
(333)

GDS  10-9520-R05

Electrochemical Smart Sensor configured for Ammonia with range 0-50/0-1000 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-49, GDS-58XP.

1200-0502
(3085)

GDS  1200-0502

GDS Gas Detector Calibration Gas Kit Ammonia (NH3) 300ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of calibration gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0501
(3084)

GDS  1200-0501

GDS Gas Detector Calibration Gas Kit Ammonia (NH3) 50ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of calibration gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> AMMONIA :    43 Items found.
51001AL-0-1015/0300P/L0
(7123)

RC SYSTEMS  51001AL-0-1015/0300P/L0

RC Systems SenSmart 5100 3-wire gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
ECFX-200-N
(6467)

HONEYWELL  ECFX-200-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-200 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,596.46 
LBW-420-1-SS
(912)

COOL AIR  LBW-420-1-SS

Cool Air LBW-420 Ammonia (NH3) 0-100/1000ppm Gas Leak Detector 4-20mA analog output. NEMA 4X enclosure. Alarm, pre-alarm and auxiliary relays. 115/230 VAC, 50/60 Hz, or 24 VDC. User Adjustable ranges: 0-100, 0-250, 0-500 and 0-1000ppm

Configure

$1,631.80 
ECFX-1000-N
(6587)

HONEYWELL  ECFX-1000-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-1000 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,654.94 
LBW-420-LEL-DC-01
(6055)

COOL AIR  LBW-420-LEL-DC-01

Cool Air LBW-420-LEL Ammonia (NH3) 0-9.9% Gas Leak Detector. Includes 4-20mA analog output, 3 latching relays and LED Display. 18-36 VDC (Optional AC). NEMA 4X and UL listed enclosure.

Configure

$1,676.90 
ECFX-500-N
(6468)

HONEYWELL  ECFX-500-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-500 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

GG-NH3-2-EXP
(4149)

CALIBRATION TECHNOLOGIES  GG-NH3-2-EXP

CTI GasGuard NH3-2%-EXP Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressorrooms where E-stop or electrical shunt trip is desired. Explosion-proof. Enclosure and sensor head certified for hazardous locations. Industry standard linear 4-20 mA output. Power: 24 VDC, 120 mA. NEC, UL, CSA, FM and IEC Approvals.

Configure

$1,786.74 
2100AL-0-9012/0300P/L0
(132)

RC SYSTEMS  2100AL-0-9012/0300P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,789.61 
LBW-HHS-II
(1556)

COOL AIR  LBW-HHS-II

Cool Air LBW-HHS-II Portable Handheld Ammonia (NH3) Leak Detector. Glass Filled Polycarbonate Housing. Includes touch-sensitive LCD display, 3 concentration alarms (caution, warning and danger), USB output, RS-232 Output Cable, 4GB of internal memory and rechargeable NiMH battery.

Configure

$1,820.40 
VL-F7-NH3-N4-LPA-NO
(3720)

HONEYWELL  VL-F7-NH3-N4-LPA-NO

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp.



 
S3KUL2-XNXXSA1SS
(685)

HONEYWELL  S3KUL2-XNXXSA1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring AMMONIA (NH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-200ppm, 0-1000ppm. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,837.05 
961-500026-100G
(6349)

DETCON  961-500026-100G

Detcon DM-102-NH3 Electrochemical Ammonia (NH3) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ECFX-100-N
(1516)

HONEYWELL  ECFX-100-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-100 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
ECFX-250-N
(6588)

HONEYWELL  ECFX-250-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-250 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
SPXCDULNA2
(1897)

HONEYWELL  SPXCDULNA2

Honeywell Sensepoint XCD RTD Gas Detector for Ammonia (NH3) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9012/0300P/L0
(6888)

RC SYSTEMS  31001AL-0-9012/0300P/L0

RC Systems SenSmart 3100 3 wire gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,967.53 
967-505090-100
(6070)

DETCON  967-505090-100

Detcon DM-702-NH3 Electrochemical Smart Ammonia (NH3) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

VL-F7-NH3-N4-LPA-MK
(3716)

HONEYWELL  VL-F7-NH3-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). continuous monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2" cast steel T. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
XNXUTAENNNNN-XNXXSA1SS
(835)

HONEYWELL  XNXUTAENNNNN-XNXXSA1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Ammonia (NH3) compatible with all Honeywell gas sensing technologies, with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-200ppm, 0-1000ppm

Configure

$2,251.86 
IR-F9-NH3-0/2-N1
(1548)

HONEYWELL  IR-F9-NH3-0/2-N1

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Ammonia (NH3) 0-20000 ppm with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.