GDS GDS-49 Remote Gas Detector Transmitter with Stainless steel sensor head configured for Oxygen (O2) with range 0-25%, Explosion Proof (XP). 2-Wire 4-20 mA transmitter.

Inquiry

The GDS-49 (Model 10-0248) two-wire toxic sensor transmitter provides a scaled 4-20mA current sink output suitable for long distance transmission to an appropriate receiver device such as a C1 or C2 Protector series controller or GASMAX transmitter.

Wide Variety of Available Sensors

The GDS-49 is compatible with all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more. Built-in fault detection circuity constantly monitors the sensor for correct operation and sensors can easily be replaced in the field.

Rugged Detection

The GDS-49 is enclosed in a stainless steel housing with integrated flame arrestor and is CSA approved for all Class I, Division 1 and 2 hazardous environments. For certain highly reactive gases that are not compatible with stainless steel, the GDS-49 is also available in a configuration without a flame arrestor that can be installed as intrinsically safe (IS) with an approved IS barrier, A standard junction box is supplied with the GDS-49 for connection to field wiring.

Calibration Required

Initial factory adjustment is completed by installing a fixed gain resistor on the sensor. This resistor establishes the range and provides basic calibration. Since the GDS-49 electronics are completely sealed and potted for maximum protection, final calibration must be performed at the receiver device in order to meet the rated accuracy specifications and accomodate changes in sensor characteristics over time. GDS Corp. offers single, dual, four, eight and sixteen + channel controllers with compatible analog inputs suitable for final calibration, alarm, display and retransmission of monitored gas values.

Easy Installation

The GDS-49 includes an XP junction box and functions with loop voltages ranging from 10-30VDC; voltage drop across the GDS-49 is less than 9 volts. An integral “transient voltage suppressor” protects the GDS-49 against lightning and other electrical transients. Non-polarized wiring elimnates wiring errors.

FEATURES

  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Compatible with all GDS Corp toxic sensors
  • Non-polarized loop powered interface eliminates wiring errors
  • Range and target gas configured by sensor module
  • Fault supervision circuitry detects failed or missing sensor & transmits warning (2mA)
  • Stainless steel case & potted electronics for high noise immunity in electrically noisy environments
  • Industry standard 4-20mA output signal for cable runs > 1000 ft
  • Available without flame arrestor for highly reactive gases
  • Easy interface to all GDS Corp 2, 4, 8 or 16+ channel controllers
  • Combine with GDS-55 Loop-Powered Alarm or GDS-54 Loop-Powered Indicator for more flexibility
  • Manufactured in USA

GDS-49 (Model 10-0248 & 10-0248IS) SPECIFICATIONS
Power Input: 10 - 30VDC 4 - 20mA current loop with less than 9V drop across GDS-49; Maximum 32mA draw with overrange sensors
Display None
Input Accepts microamp-level signals from local GDS Corp toxic or oxygen deficiency sensors
Calibration Range Rough calibration set by sensor; final calibration must be performed by remote receiver device
Accuracy +/- 5% of full scale range (typical)
Standard Output Standard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp --25°C to +60°C (see sensor limitations)
Housing GDS-49 Stainless steel with or without flame arrestor
Dimensions Width 5.3” x Height 9.3” x Depth 2.75” with splash guard
Shipping weight 6.5 pounds (3 kg)
Approvals Model 10-0248 CSA Certified for Div. 1 & 2 Groups B, C, D Exia. Suitable for Explosion Proof and Intrinsically Safe installations.
Model 10-0248IS CSA Certified for Div. 1 & 2 Groups A, B, C, D. Suitable for Intrinsically Safe only.
IMPORTANT: Intrinsically Safe installations require IS barrier 10-0263 (MTL 7787P+) or equivalent./td>
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    9 Items found.
FC-11
(1563)

AUTOMATION DIRECT  FC-11

Signal conditioner and isolator with loop-powered 4-20 mA input and output signal; output can be field calibrated with offset and span adjustments. Slim-line plastic housing with integral 35mm DIN rail mounting adapter and removable screw terminals, 24VDC supply voltage. UL 508 listed, UL listed for Class I, Division 2, Groups A, B, C, D hazardous locations.



$174.00 
1200-0550
(3202)

GDS  1200-0550

GDS Gas Detector Calibration Gas Cylinder Oxygen (O2) 18%. Balance Nitrogen. 103L Aluminium Cylinder.

1200-0549
(3201)

GDS  1200-0549

GDS Gas Detector Calibration Gas Cylinder Oxygen (O2) 8%. Balance Nitrogen. 103L Aluminium Cylinder.

(261)

GDS  10-0263

GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent



 
10-9010-R04
(2053)

GDS  10-9010-R04

Electrochemical Sensor for GDS-49 remote transmitter configured for Oxygen (O2) with range 0-25%.



 
10-9510-R04
(294)

GDS  10-9510-R04

Electrochemical Smart Sensor configured for Oxygen (O2) with range 0-25%. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-49, GDS-58XP.

1200-0528
(3135)

GDS  1200-0528

GDS Gas Detector Calibration Gas Kit Oxygen (O2) 18%. Balance Nitrogen. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0527
(3134)

GDS  1200-0527

GDS Gas Detector Calibration Gas Kit Oxygen (O2) 8%. Balance Nitrogen. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> OXYGEN :    30 Items found.
41001AL-0-1010/0025P/L0
(7176)

RC SYSTEMS  41001AL-0-1010/0025P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Oxygen (O2) 0-25% vol with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1010/25V/L0
(7131)

RC SYSTEMS  51001AL-0-1010/25V/L0

RC Systems SenSmart 5100 3-wire gas detector for Oxygen (O2) 0-25% vol. with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
967-343490-25P
(6065)

DETCON  967-343490-25P

Detcon DM-700-O2 Electrochemical Smart Oxygen (O2) 0-25% Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNO2
(5108)

HONEYWELL  SPXCDULNO2

Honeywell Sensepoint XCD RTD Gas Detector for Oxygen (O2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 25% v/v. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
961-340026-025G
(6372)

DETCON  961-340026-025G

Detcon DM-100-O2 Electrochemical Oxygen (O2) 0-25%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2100AL-0-9010/25V/L0
(116)

RC SYSTEMS  2100AL-0-9010/25V/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
31001AL-0-9010/25V/L0
(5787)

RC SYSTEMS  31001AL-0-9010/25V/L0

RC Systems SenSmart 3100 3 wire gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
XNXUTAENNNNN-XNXXSO1SS
(849)

HONEYWELL  XNXUTAENNNNN-XNXXSO1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Oxygen (O2) 0-25%VOL compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$1,969.63 
6100AL1-0-1010/0025P
(7013)

RC SYSTEMS  6100AL1-0-1010/0025P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Oxygen (O2) 0-25% vol with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
GG2SAXXX-X-O2
(5019)

ION SCIENCE  GG2SAXXX-X-O2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Oxygen (O2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***