Interscan I-900g-c2h4-0002 | Ethylene | Gas Detectors (portable) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

INTERSCAN   I-900G-C2H4-0002

INTERSCAN I-900G-C2H4-0002
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Interscan GASD 8000 Portable Trace Gas Detector with smart sensor for continuous air sampling of Ethylene (C2H4). Anodized aluminum enclosure. Includes rechargeable batteries.

I-900G-C2H4-0002   
5,688.00

Range

   4 Weeks  ]
5 Variants of base SKU

Ensure the safety of your employees and workplace with industry-leading sensor technology the fastest sensor replacement process in the industry. With smart sensor technology built-in, the GasD 8000 is capable of extremely low (trace) levels of detection, and with continuous air exchange, gives an accurate and holistic measurement of the surrounding area. A portable and rugged design allow the GasD to be transported and used in many locations, and replacing sensors can be done by the user in the field - without the need to send the device back to the manufacturer.

GASD 8000 Features
  • Continuous air sampling (vs. passive) for more accurate and comprehensive readings.
  • Industry-leading sensor technology capable of extremely low (trace) detection levels.
  • Portable form factor for convenient gas detection in any area.
  • Easy and fast sensor replacement.
  • Rechargeable batteries with up to 8 hours of continuous service.
  • Easy-to-read and navigate user interface.
  • Used by a wide range of industries.

Product Specifications
Accuracy±2% of reading ±1 least significant digit
DisplaySunlight visible transflective LCD
Operating environment32°F —113°F (0°C — 45°C) ; 0-90% relative humidity
Internal BatteryRechargeable Lithium-Ion (5000 mAh)
Data LoggingVia integral SD card (32 GB)
Dimensions51/2 in H x 81/4 in W x 10 in D (140 x 210 x 254 mm) Includes body and legs
Weight6.5 lb (2.95 kg)
Enclosure/td>Anodized aluminum
Power (when plugged in)Universal AC outlet adapter. Rated voltage 100-240V, 50/60hz, USB A. Total output: 5V, 2400 mA or higher.
CalibrationAgainst standard gas mixture, or via lnterscan's SENSOR EXPRESS®

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
P-7434
(6788)

PROSENSE  P-7434

Prosense P-7434 Gas Detector with Electrochemical sensor for Formaldehyde (CH2O) with ranges 0-10ppm or 0-100% LEL(7% Vol cat bead). Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,003.86 
PQD-7434-1/2
(6749)

PROSENSE  PQD-7434-1/2

Prosense PQD-7434 Gas Detector with Electrochemical sensor for Formaldehyde (CH2O) with ranges 0-10ppm or 0-100% LEL(7% Vol cat bead). Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,338.48 
961-EP0026-100G
(6360)

DETCON  961-EP0026-100G

Detcon DM-100-CH2O Electrochemical Formaldehyde (CH2O) 0-100ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

> ETHYLENE :    4 Items found.
961-ED0026-100G
(6357)

DETCON  961-ED0026-100G

Detcon DM-100-C2H4 Electrochemical Ethylene (C2H4) 0-100ppm or 0-200ppm Sensor Assembly with optional loop powered display. 4-100 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

967-12ED90-100
(6081)

DETCON  967-12ED90-100

Detcon DM-700-C2H4 Electrochemical Smart Ethylene (C2H4) 0-100 ppm or 0-200 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

2108N4101N
(1967)

HONEYWELL  2108N4101N

Honeywell Ethylene Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for LEL, 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Ethylene calibration with dust barrier, weather housing, deluge/heat shade, configured as current source output. Optional remote gassing cell.

Configure

$2,244.54 
2108N5101N
(1968)

HONEYWELL  2108N5101N

Honeywell Ethylene Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector for LEL. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Ethylene calibration, for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output

Configure

$2,955.96 