Honeywell Spxcdulnfx | Lel Catalytic Bead | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   SPXCDULNFX

SKU# (658)



HONEYWELL SPXCDULNFX
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (LNG-natural gas), Propane C3H8 (LPG), Butane C4H10, Pentane, Hexane, Ethanol, Hydrogen with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20 mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Div 1 or ATEX (Zone 1) IECEx available.

DISPLAY   4-20 mA   RELAYS   UL   ATEX   IECEX   CSA   UL   DIV 1   ZONE 1   MODBUS

SPXCDULNFX   
1,837.75

Modbus RTU
Enclosure
Agency Approval
Entry
Sunshade/Deluge Protection
Calibration 0-100% LEL
Custom Tag
Junction Box

   In Stock  ]

Standard configurations typically available in In Stock:
SPXCDULNFX    SPXCDULNFX-???    SPXCDULNFX-???    SPXCDULNFX-???-TAG    SPXCDULNFX-TAG
16 Variants of base SKU
XCD normal display (green) XCD Display in Fault/Warning (Yellow) XCD display in Alarm (Red)
Normal Fault/Warning Alarm
FEATURES

One-Stop Shop
  • Flammable (catalytic or infrared), toxic and oxygen versions available
  • New and retrofit applications
  • Suitable for indoor or outdoor use
  • Stainless steel or aluminium explosion-proof housing options
  • IP66 as standard
Proven and Reliable Sensor Technology
  • SurecellTM electrochemical sensors
  • ReflexŪ sensor health check
  • Poison immune infrared sensors
  • Poison resistant catalytic bead sensors
  • Long life sensors
Global Approvals
  • US and Latin America, European, Canadian and Asian
  • Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
  • User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
  • Fully configurable via magnetic switches
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance
  • MODBUS communications for remote diagnostics/configuration
Cost Effective
  • Common transmitter platform
  • Minimal training required
  • Reduced spares
  • Non-intrusive, one-man operation
  • Plug-in sensor replacement
  • MODBUS multi drop option offers cabling savings
Simple Installation
  • Plug-in display module removes to give access to terminal area
  • Integral mounting bracket
  • 2 x M20 or 3⁄4” NPT cable/conduit entries (certification dependent)
  • Removable plug/socket type terminal blocks for ease of wiring
  • Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
  • Remote sensor gassing kit
  • Duct mounting kit
  • Calibration gas flow housing
  • Collecting cone

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs

Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors, downtime is also reduced and on-going costs are minimized through the use of poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented SurecellTM toxic sensors and ReflexŪ sensor health check.

All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and Modbus.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or 3⁄4”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.

TYPICAL APPLICATIONS

  • Industrial manufacturing facilities
  • Power plants
  • Waste water facilities
  • Utilities
  • Food and beverage production
  • Refineries and chemical plants
  • Onshore oil and gas terminals
  • Production platforms
  • Exploration and drilling
Honeywell XCD detector components

1 Cover
2 Display module
3Terminal area
4 Blanking plug
5 Transmitter
6 Plug-in XCD sensor
7 Sensor retaining ring
8 Integral mounting plate
9 Weather protection assembly
10 Cable/conduit entry (x2)
11 Certification label

There are three different types of the XCD transmitter for use with three different families of sensors.

The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL, as well as Carbon Dioxide (CO2) in the range 0-2%Vol.

The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulfide, (H2S), Hydrogen (H2) and Nitrogen Dioxide (NO2).

The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors.

A transmitter can auto-recognize any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.

Sensepoint XCD uses three instantly recognizable ‘traffic light’ colors to indicate its status. The large tri-color backlit LCD is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.

Specifications
Gas Flammable 1 to 8
Sensor Family mV
User Selectable Full Scale Range 20.0 to 100.0%LEL
Default Range 100%LEL
Steps 10%LEL
User Selectable Cal Gas Range 30 to 70% of selected full scale range
Default Cal Point 50%LEL
Response Time (T90) Secs <25
Accuracy <+/-1.5%LEL
Min Operating Temperature -20°C / -4°F
Max Operating Temperature 55°C / 131°F
Default Alarm Point A1 20%LEL ▲
Default Alarm Point A2 40%LEL ▲

General Transmitter Specifications
Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and Oxygen hazards. Incorporating a transmitter with local display and fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized
Communication RS485, MODBUS RTU
Construction
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: 316 stainless steel
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries UL\cUL versions: 2 x ū"NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating; ATEX/IECEx versions: 2 x M20 cable entries
Environmental
IP Rating IP66 in accordance with EN60529:1992

Certification
US, Latin America, Canada UL/c-UL - Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40°C to +65°C
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
EMC CE: EN50270:2006 EN6100-6-4:2007
Performance UL508; CSA 22.2 No. 152 (flammable gasses, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors) “CCCF” Shenyang for Flammable (fire dept approval)

Honeywell Sensepoint XCD Part Number

Honeywell Sensepoint XCD Option Matrix

Export Info
Made inSouth Korea
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping & Handling

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    18 Items found.
(672)

HONEYWELL  SPXCDHMANEN

Hard Copy Manual in English for Honeywell Sensepoint XCD Sensors. *** Phased Out ***



$79.37 
SPXCDMTBR
(670)

HONEYWELL  SPXCDMTBR

Mounting bracket for Honeywell Sensepoint XCD Sensors. Includes bolts, nuts and brackets



$141.92 
S3KCAL
(667)

HONEYWELL  S3KCAL

Calibration Cap/Cup for Honeywell Sensepoint XCD Sensors.



$156.35 
10624200
(1305)

PORTAGAS  10624200

Calibration Gas Propane (C3H8) 50% LEL 1.06% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
90302139
(1259)

PORTAGAS  90302139

Calibration Gas Butane (C4H10) 50% LEL (0.9%) Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
90095187
(6713)

PORTAGAS  90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1% Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
10305400
(3238)

PORTAGAS  10305400

Calibration Gas Hexane 40% LEL (4400 ppm) Balance Air Size 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder (Made by Portagas)

Configure

$158.48 
10241000
(4296)

PORTAGAS  10241000

Calibration Gas Ethane (C2H6) 50% LEL 1.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
90301910
(933)

PORTAGAS  90301910

Calibration Gas Hydrogen (H2), 50% LEL 2% vol Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
90095251
(2040)

PORTAGAS  90095251

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
90090227
(1313)

PORTAGAS  90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. Alternate part number 10444000 (Made by Portagas)

Configure

$158.48 
90095224
(2926)

PORTAGAS  90095224

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
90411390
(2927)

PORTAGAS  90411390

Calibration Gas Hydrogen (H2) 60% LEL 2.4% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$158.48 
SPXCDCC
(668)

HONEYWELL  SPXCDCC

Collecting cone for use with lighter than air gases for Honeywell Sensepoint XCD Sensors.



$161.16 
SPXCDSDP
(671)

HONEYWELL  SPXCDSDP

Sunshade/Deluge Protection for Honeywell Sensepoint XCD Sensors.



$528.76 
SPXCDDMK
(669)

HONEYWELL  SPXCDDMK

Duct mounting kit for Honeywell Sensepoint XCD Sensors, to monitor the presence of gas inside a Heating, Ventilation or Air Conditioning (HVAC). A duct or plenum is required.



$581.75 
SPXCDXSFXSS
(675)

HONEYWELL  SPXCDXSFXSS

Replacement Sensor Cartridge for Flammable CAT (Catalytic) XCD Detector 0-100%LEL (20.0 to 100.0%LEL)



$708.94 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote ... more

Configure

$3,043.01 
> LEL CATALYTIC BEAD :    36 Items found.
GD-2B
(2047)

MACURCO  GD-2B

Macurco GD-2B Gas Detector for combustibles (heating type gases). Low voltage and designed for connection to Fire Alarm/Burglary Control Panels. 9-32 VDC or 12-24 VAC input. Meets UL 2075 standard. Alarm, trouble relays and 85dB buzzer.



$137.60 
GD-2A
(650)

MACURCO  GD-2A

MACURCO Combustible Gas Detector low voltage all-electronic monitor engineered to detect heating type gases, including methane (natural gas) and propane(bottled gas). 12-24 VAC or VDC input. SPDT alarm and NC trouble relays. Listed to UL Standard 2075. CSFM Approved.



$137.60 
SV-3002
(7373)

PROSENSE  SV-3002

Prosense SafeVader SV-3002 Fixed Gas Detector with Catalytic Bead sensor for Hydrocarbons (Methane, Propane, Butane, LPG, Hydrogen, Gasoline/Petrol Vapor and other combustibles) with range 0-100% LEL. 4-20 mA Analog, Modbus RS485 RTU and relay outputs (Alarm1, Alarm2, Fault). 12 to ... more

Configure

$236.99 
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs. Optional ... more

Configure

$272.15 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, Petrol/Gasoline Vapor, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20 mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$301.33 
P-3012PEK
(6800)

PROSENSE  P-3012PEK

Prosense P-XY12PEK Gas Detector with Catalytic Bead and Motion sensor for Hydrocarbons (LPG, Methane, Petrol/Gasoline Vapor, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20 mA Analog and Modbus RS485 RTU outputs. ... more

Configure

$369.34 
GD-6
(1234)

MACURCO  GD-6

MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC ... more

Configure

$503.70 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog ... more

Configure

$515.17 
P-5235
(6774)

PROSENSE  P-5235

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Cyclo Hexane, Cyclo Pentane, Dioxane, Butyl Alcohol, Styrene, Xylene, Acetylene, Ethylene Oxide, Vinyl Acetate, JP8 Fuel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and ... more

Configure

$515.17 
GD-12
(3416)

MACURCO  GD-12

MACURCO GD-12 line voltage Gas Detector, controller and transducer for Combustibles (EX) 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 100 to 240 ... more

Configure

$524.40 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas ... more

Configure

$633.81 
PXN-3035-1/2
(7322)

PROSENSE  PXN-3035-1/2

Prosense PXN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (LPG, Methane, Petrol/Gasoline Vapor, Butane, Propane, Hexane, Hydrogen, Pentane, Toluene, Methyl Alcohol, Heptane, Octane, Ethyl Alcohol, Carbon Monoxide, Acetone, Ethylene, Ethane, Propylene, Xylene, Benzene and more) with range 0-100% ... more

Configure

$699.86 
PXN-5235-1/2
(7340)

PROSENSE  PXN-5235-1/2

Prosense PXN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Cyclo Hexane, Cyclo Pentane, Dioxane, Butyl Alcohol, Styrene, Xylene, Acetylene, Ethylene Oxide, Vinyl Acetate, JP8 Fuel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and ... more

Configure

$699.86 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$749.16 
PQN-5235-1/2
(6950)

PROSENSE  PQN-5235-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Cyclo Hexane, Cyclo Pentane, Dioxane, Butyl Alcohol, Styrene, Xylene, Acetylene, Ethylene Oxide, Vinyl Acetate, JP8 Fuel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and ... more

Configure

$767.90 
PQN-3035-1/2
(6947)

PROSENSE  PQN-3035-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog ... more

Configure

$767.90 
PXD-5235-1/2
(7339)

PROSENSE  PXD-5235-1/2

Prosense PXD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Cyclo Hexane, Cyclo Pentane, Dioxane, Butyl Alcohol, Styrene, Xylene, Acetylene, Ethylene Oxide, Vinyl Acetate, JP8 Fuel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing ... more

Configure

$865.10 
PXD-3035-1/2
(7321)

PROSENSE  PXD-3035-1/2

Prosense PXD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (LPG, Methane, Petrol/Gasoline Vapor, Butane, Propane, Hexane, Hydrogen, Pentane, Toluene, Methyl Alcohol, Heptane, Octane, Ethyl Alcohol, Carbon Monoxide, Acetone, Ethylene, Ethane, Propylene, Xylene, Benzene and more) with range ... more

Configure

$865.10 
PQD-3035-1/2
(6718)

PROSENSE  PQD-3035-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20 mA Analog ... more

Configure

$952.58 
PQD-5235-1/2
(6736)

PROSENSE  PQD-5235-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Cyclo Hexane, Cyclo Pentane, Dioxane, Butyl Alcohol, Styrene, Xylene, Acetylene, Ethylene Oxide, Vinyl Acetate, JP8 Fuel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and ... more

Configure

$952.58 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.