Delphian GazTell Fixed Point Electrochemical Gas Detector for Nitrogen Dioxide (NO2) 0-100ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

364-455-01-365-732-01   
Please Email us your request for quote   

Remote Display
Alarm Relays
Communications Module
Mounting Options
Sensor Adaptors
Splash Guard

   2 Days  ]

Hassle free safety:
  • Simple to use and install
  • Shock & vibration resistant
  • Low power consumption
  • Checks itself every second
  • Plain English displays
  • Tough
  • Reliable
  • Affordable
  • Accurate
THE DETECTOR HEAD

The GazTell detector head for electrochemical cells can be used alone or with the optional modules.

  • The small size (5”L x 2”W) makes it inconspicuous and allows placement in tight areas.
  • User-friendly, alpha-numeric LED display with understandable instructions and prompts.
  • Automatically recognizes the sensor cell with no configuration necessary.
  • Scrolls gas type every few seconds.
  • Low maintenance and low cost of ownership. The detector head logs and will display the last time it was calibrated.
  • Connects directly to conduit eliminating the need for expensive and bulky junction boxes.
  • Smart Sensor saves operator time and money. The sensor knows the highest reading since last calibration, the number of days since last calibration, how long the detector head has been in service, the percentage of life remaining in the sensor and highest/lowest temperatures observed during operation. It checks itself and its vital functions continuously.
  • Power consumption is very low. Even at its maximum power consumption (with the display at its brightest), the detector head uses only 77mA @ 24VDC.
OPTIONAL SLAM
Remote Relay Module
  • Set alarm levels without software, using simple jumper selection.
  • The module can be placed anywhere relays are needed.
  • Flexible design allows the relays to be placed next to the functions they operate.
  • The relay module has robust relays rated at 6 amp@120 volt relays for Fail, Low and High Alarms, so auxiliary relays are often not needed. Alarm relays can be latching or non-latching, energized or de-energized, normally open or closed. A 5 second alarm delay can be turned on to avoid false alarms.
  • FM Approvals tested the SLAM module for operation at -4 oF to 140 oF (-20 oC to +60 oC).
OPTIONAL EXMO
Remote Display Module

The EXMO communicates directly with the detector head and mimics its display. If the detector head is located remotely high or low, or in a difficult-to-calibrate place, locating the EXMO in an accessible position gives immediate access to the detector head’s sensor. It displays everything the detector head displays. It gives control via bi-directional RS-485 communication.

Remote calibration has never been so easy.

The small extension module has the same alpha numeric LED displays and color coded operation as the remotely placed detector head.

  • Check the sensor before entering a dangerous area.
  • Take the sensor online or offline
  • Calibrate
  • Cancel calibration

SPECIFICATIONS
DimensionsDetector Head: 5"L x 2"W
EXMO, SLAM & COMO: (each) 6"L x 3.5"W x 2"H
Shipping Weight Detector Head: .875 lbs (.4 kg)
EXMO, SLAM & COMO: (each) 1.25 lbs (.6 kg)
Power: Detector Head: 77 mA max
EXMO: 16mA max
SLAM: 56 mA max
COMO: 35 mA max
Operating Voltage Nominally 12-42 VDC
Output Signal Range 4-20mA or 1-5 mA (user selectable, 4 - 20mA is default). Modbus RTU available as an option.
Output is linear and proportional to the gas scale.
Load (maximum resistance) 300 Ohms
Measurement Ranges ppm according to toxic gas electrochemical cell and % by volume for oxygen.
Temperature Range Cell Storage: +32 oF (0 oC) to +68 oF (+20 oC)
The detector head: (depending upon cell installed)
-20 oC (-4 oF) to +70 oC (+158 oF)
The EXMO/SLAM/COMO:
-20 oC (-4 oF) to +60 oC (+140 oF)
Pressure The operating pressure range for toxic cells is normally ambient +/-10%
Mean Time Between Failures (MTBF@70F) 8 years (electronics)
SLAM Relays 6 amps@120 volts
SLAM Response Time Less than a second from the time the detector head sees sufficient gas to trigger an alarm to the relay operating.
EXMO Response Time Less than a second from the time the detector head sees gas to the EXMO displaying that gas concentration.
Detector Head RFI/EMI Immunity Less than 1% of full scale change with 5w transceiver keyed within three feet. RFI/EMI Protection complies with EN50270, EN61000-6-4, ISA/IEC 6001-4-3
Area Hazard Classification: Class I, Divisions 1 & 2, Groups C, D
SIL (Safety Integrity Level) SIL 2
Warranty Detector Head, SLAM, EXMO and COMO: two years from date of shipment.
Cell: one year from date of shipment.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> NITROGEN DIOXIDE :    28 Items found.
M001-0011-000
(6004)

MPOWER  M001-0011-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitrogen Dioxide (NO2) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
TX1-4
(5967)

INDUSTRIAL SCIENTIFIC  TX1-4

Industrial Scientific Tango TX1 Gas Detector for Nitrogen Dioxide (NO2) 1-150 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

PPS+-NO2
(6814)

PROSENSE  PPS+-NO2

Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



$429.00 
PPS-RNO2
(6812)

PROSENSE  PPS-RNO2

Prosense PPS-RNO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$429.00 
BWS1-D-Y
(6391)

BW  BWS1-D-Y

BW Solo Serviceable Single-gas Detector for Nitrogen dioxide (NO2) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-ND
(2046)

MACURCO  TX-6-ND

Macurco TX-6-ND low voltage Gas Detector, Controller and Transducer for Nitrogen Dioxide (NO2) 0-20 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1.

Configure

$648.99 
TX-12-ND
(3417)

MACURCO  TX-12-ND

MACURCO TX-12-ND line voltage Gas Detector, controller and transducer for Nitrogen Dioxide (NO2) 0-20ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$656.26 
PC3-6824
(6809)

PROSENSE  PC3-6824

Prosense PC3-6824 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-6834
(6784)

PROSENSE  P-6834

Prosense P-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXN1
(1924)

HONEYWELL  SPSTAXN1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Nitrogen dioxide (NO2) 0-10ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$993.35 
PQN-6834-1/2
(6957)

PROSENSE  PQN-6834-1/2

Prosense PQN-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
GG-NO2-B-10
(5982)

CALIBRATION TECHNOLOGIES  GG-NO2-B-10

CTI GG-NO2-B Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. NEMA 3RX polycarbonate housing. CSA and UL approved.

Configure

$1,122.00 
2106B1422
(1467)

HONEYWELL  2106B1422

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitrogen Dioxide (NO2) 0-10 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
PQD-6834-1/2
(6745)

PROSENSE  PQD-6834-1/2

Prosense PQD-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109024/007P-L0
(6915)

RC SYSTEMS  1100ALD-109024/007P-L0

RC Systems SenSmart 1100 gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,314.28 
GG-NO2-10-EXP
(5980)

CALIBRATION TECHNOLOGIES  GG-NO2-10-EXP

CTI GG-NO2-EXP Explosion Proof Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
41001AL-0-1024/0005P/L0
(7175)

RC SYSTEMS  41001AL-0-1024/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1024/0005P/L0
(7130)

RC SYSTEMS  51001AL-0-1024/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-640026-010G
(6371)

DETCON  961-640026-010G

Detcon DM-100-NO2 Electrochemical Nitrogen Dioxide (NO2) 0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

SPXCDULNN2
(5107)

HONEYWELL  SPXCDULNN2

Honeywell Sensepoint XCD RTD Gas Detector for Nitrogen dioxide (NO2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 10 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
Page: 1 | 2 | All