GasDetectorsUSA.com Logo
|NH3 |CO2 |H2S |LEL |VOC PID |Cal Kits |Portables |Portables Multi-Gas |PLC & SCADA| |NIOSH Exposure Limits|
PROFESSIONAL INTEGRATION of Industrial Gas Detection Systems                   Shopping Cart
Products & Services
 ACCESORIES
 ANALYZERS
 CALIBRATION
 FLAME DETECTORS
 GAS DETECTORS
     AMMONIA  (6)
     ARSINE  (6)
     CARBON DIOXIDE  (12)
     CARBON DIOXIDE AND OXYGEN  (1)
     CARBON MONOXIDE  (6)
     CHLORINE  (6)
     CHLORINE DIOXIDE  (6)
     ETHYLENE OXIDE  (6)
     FLUORINE  (6)
     HYDRAZINE  (6)
     HYDROGEN  (6)
     HYDROGEN CHLORIDE  (6)
     HYDROGEN CYANIDE  (6)
     HYDROGEN FLUORIDE  (6)
     HYDROGEN SULFIDE  (6)
     LEL (EXPLOSIVE)  (15)
     LEL AND HYDROGEN  (1)
     LEL AND OXYGEN  (1)
     LEL AND TOXIC  (18)
     LEL CAT BEAD (GAS LIST)  (1)
     LEL IR (GAS LIST)  (1)
     LEL IR AND HYDROGEN  (1)
     LEL IR AND OXYGEN  (1)
     LEL IR AND TOXIC  (17)
     MERCAPTAN  (6)
     NITRIC OXIDE  (6)
     NITROGEN DIOXIDE  (6)
     OXYGEN  (6)
     OZONE  (6)
     SILANE  (6)
     SULFUR DIOXIDE  (6)
     TETRAHYDROTHIOPHENE  (6)
     VOC (GAS LIST)  (1)
     VOC PID  (4)
     VOC PID AND HYDROGEN  (1)
     VOC PID AND OXYGEN  (1)
     VOC PID AND TOXIC  (11)
 INSTALLATION
 MULTI-POINT CONTROLLERS
 OPTIONS
 PERSONAL SAFETY
 SENSORS
 SYSTEMS INTEGRATION
Legal Exposure Limits
[ NIOSH Exposure Limits ]

Why GasDetectors.com ?

  • GasDetectorsUSA.com provides a wide range of industrial gas detection systems including toxic, oxygen and combustibles, truly "state of the art" devices offering unparalleled features and capabilities along with OSHA and CSA certifications at a reasonable price. We also offer gas detection solutions with PLC & SCADA.

  • Our Broad spectrum of skills, experience and hands-on approach ensures the success of Your project
  • We provide specialized products, services or turnkey projects, to suit your needs in
    • Fixed gas detectors.
    • Portable gas detectors.
    • Multi-Point gas controllers.
    • Installation and commissioning.
    • Periodic calibration and maintenance.
    • PLC-based gas detection solutions.
    • Data acquisition and SCADA.


Houston, TX USA (832) 615-3588

©2009 Miramar Automation Web Solutions

Printer Friendly Page  
GASMAX-GMII-000-97-1

GASMAX-GMII-000-97-1-11

SKU# 566

  • Overview
  • Features
  • Specs
  • Related
  • Documents
  • $

GAS DETECTORS > CARBON DIOXIDE

GASMAX II 3-Wire Gas Monitor with local stainless steel sensor head configured for GDS-IR-CO2 0-5% (0-50,000 ppm) Carbon Dioxide (CO2), 4-20 mA output transmitter. Includes Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Single/Dual channel Toxic / O2 / LEL.

  • No routine calibration required
  • Incorporates reliable dual wavelength infrared technology
  • Fault indication for failure conditions
  • Failsafe operation of vital functions in dirty conditions
  • Optics can be cleaned and maintained by user.
  • 5 year MTBF and lower total cost of ownership.

The GDS-IR Infrared Remote Point Gas Detector 3-Wire output 4-20 mA can be remotely installed at locations in excess of 1000 ft from the monitor or controller. GDS-IR sensors offer a 5 year MTBF and lower total cost of ownership.

The GDS-IR Infrared Point Gas Detector uses infrared light to detect hydrocarbon content in ambient air. The dual wavelength detector compares a reference wavelength to an analytical wavelength; target gases absorb the analytical energy but do not affect the reference. The resulting imbalance is proportional to the target gas concentration.

Typical GDS-IR installations require only one auto-zero calibration after start-up. This “no routine calibrations needed” feature, along with ease of installation, greatly reduces the GDS-IR cost of ownership when evaluated over periods as short as one year. Competing catalytic bead sensors require frequent calibration and must be replaced every two to three years at costs as high as several hundred dollars each.

Recognizing the need for high reliability, the GDS-IR output is programmed to respond to multiple failure modes. Dirty optics are indicated by transmitting 1mA continuously, and sensor failure by transmitting 0.0mA. Calibration-in-progress generates an output of 2.2mA and calibration failures an output 1.6mA.

The rugged explosion-proof stainless steel housing makes it suitable for applications in the harshest of environments. These include offshore platforms, petrochemical plants, refineries, waste disposal facilities, parking garages and many others. When combined with the GDS Corp. model GASMAX II Gas Monitor, local LCD readout, alarm relays, Modbus® RS- 485 or isolated 4-20mA output are available. A toxic or oxygen gas channel may also be combined with the GDS-IR when the GASMAX/II is added.

The SmartIR sensor, configurable for %LEL Methane, %Volume Hydrocarbons or % Volume Carbon Dioxide provides a complete IR solution that includes optics, electronics, linearization and temperature compensation.

The GASMAX II single / dual channel Toxic / O2 / LEL gas monitor delivers the latest gas detection technology, reliability and ease of use. Available in both single and dual channel models, the GASMAX II is CSA certified for use in Div 1 & Div 2 explosion proof installations. For low temperature applications, an Arctic Monitor option enables operation to –55°C ambient.

The highly visible backlit display shows calibrated engineering values, bargraph data, 30-minute trend and setup information. An internal real-time clock time-stamps calibration and alarm events for later review. Front panel LEDs continuously indicate alarms.


In addition to dual 4-20mA current loop outputs, an RS-485 two-wire MODBUS® interface and three optional 5A relays are available to communicate with controllers or local alarm indicators.

Operator interface is via a menu-driven magnetic keypad, allowing complete setup and calibration without hazardous area declassification.

The GASMAX II maintains a record of sensor calibration data that provides an estimate of sensor life remaining. During each post-calibration purge delay, the GASMAX II can be programmed to transmit this data on the 4-20mA output.

Locally connected Smart Sensors enhance this capability by maintaining their own electronic record of serial number,born-on date, initial calibration values, engineering units and other data, ensuring the most accurate measurement and alarming capability available today.

Available Ranges

  • 0-5% (0-50,000 ppm)
Options:
  • EC channel: Accepts signals from GDS Corp toxic / O2 sensors
  • Stainless Steel Enclosure
  • ATEX Certified (not available with Aluminum sensor head)
  • Wireless 900 MHz

  • Certified for use in Explosion Proof and Intrinsically Safe Installations.
  • Monitor both Toxic / O2 and LEL / VOC from single point.
  • Standard dual 3-wire 4-20mA current source (optional output 3-wire with EC sensor).
  • Non-intrusive one-person prompted calibration.
  • Smart Sensors store calibration & alarm events.
  • Real time clock tags alarm events.
  • Aluminum sensor head available for reactive gases.
  • Backlit display for better visibility in low light.

Sensor Head Options

  1. Local Stainless Steel - XP & IS
  2. Local Stainless Steel (with splash guard) - XP & IS
  3. Local Aluminum - IS ONLY
  4. Local Aluminum (with splash guard) - IS ONLY
  5. Remote Stainless Steel - XP & IS
  6. Remote Stainless Steel (with splash guard) - XP & IS
  7. Remote Aluminum - IS ONLY
  8. Remote Aluminum (w/ splash guard) - IS ONLY

Notes:

  1. Remote sensor installations do not utilize Smart Sensor interface
  2. Maximum distance for remote e-chem sensor connection is 25ft (3m).
  3. Maximun distance for remote LEL sensor connection is 300 ft.
  4. Highly reactive gases REQUIRE aluminum sensor head and IS in hazardous area.

Operation and Maintenance Manual of the GasMax Detectors

Quick Start Guides for the GasMax-II:

    Quick Start     VOC/PID     SmartIR     GDS-IR     Catalytic Bead


Operating Voltage 10-30VDC at < 3 watts with relay board. Additional power (4W peak) required for Arctic Monitor option.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and eunits.
Output Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply.
Temp Range -40°C to +65°C operating, -55°C to +65°C operating (Arctic)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel opt
Dimensions Width 5.4” (137 mm), Height 8” (203mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals: CSA Certified Div 1 & 2 Groups B, C, D. Suitable for XP installations

Warranty Two years on electronics and one year on sensors from date of purchase
Typical Sensor Life 5 years


  • ACCESORIES > POWER SUPPLIES
    PV15-24S Power Supply 25 Watts, chassis mounting, Input: 90-264 VAC, Output 24 VDC, 0.63 A, with adjustable range output. Protections: short-circuit / over voltage / over load. ..
  • ACCESORIES > ALARMS: HORNS AND INDICATORS
    AV1-120X Audible/Visual Signal Alarm NEMA 3R can be mounted on GDS gas detectors. Power: 120 VAC. ..
  • OPTIONS > STAINLESS STEEL OPTION
    GASMAX-SS STAINLESS STEEL 316 detector housing option for all GDS GasMax detectors. ..
  • OPTIONS > WIRELESS OPTION
    GASMAXIIx Optional Wireless internal board configured for GasMaxII gas detectors, Built-in 1 watt 900Mhz license-free wireless radio (US, Canada), Range up to 20 miles with hi-gain external antenna (option..
  • CALIBRATION > CALIBRATION KITS
    CK-CO2-500-1 Gas Calibration Kit for Carbon Dioxide CO2, 10,000 ppm (balance Air) 103L ..

-$2,460.00      