Esp Safety 100-0008-ss/100-0015-nh3 | Ammonia | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

ESP SAFETY   100-0008-SS/100-0015-NH3

ESP SAFETY 100-0008-SS/100-0015-NH3
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Ammonia (NH3) 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

100-0008-SS/100-0015-NH3   
1,440.00

Enclosure Type
Optional Sensor

 6 Weeks  ]
2 Variants of base SKU

ESP Safety’s Vector is a state-of the-art field control unit that performs as an integrated control terminal and display for ESP Safety’s gas detector product line.

The Vector can operate as a stand-alone display for a variety of ESP Safety’s detectors which can be remotely located up to 500 feet away. A sensor head can also be attached directly to the display housing to produce a unified detector/display unit.

Key Features
  • A vivid, 2.7” (diagonal) 128x64 pixel resolution, OLED screen simultaneously displays a wide range of data including gas concentrations, alarm levels, faults and operational modes.
  • Analog 4-20 current loop w/ HART , Digital RS-485 Modbus RTU and 4 relays are standard data communication channels of the VECTOR FCU
  • Event log is stored in on-board memory and is accessible via RS-485 Modbus RTU
  • Operating Temp Range of -58°F to +167°F (-50°C to +75°C)
  • Configurable to control & monitor up to 2 detectors
  • SIL certification by independent 3rd party agency
  • 316 Stainless Steel construction, explosion-proof housing, Class 1, Division 1
  • Non-Instrusive, on-site detector calibration via a HART Field Communicator or Magnectic Wand
Applications
  • Offshore platforms
  • Land rigs
  • Shipping tankers, freighters, and other vessels
  • LNG/LPG processing & storage facilities
  • Oil & gas refineries
  • Petrochemical plants
  • Gas & electric utilities
Additional Features
  • Non-intrusive operator interface is easily achieved by contacting a magnetic wand with the glass housing cover and accessing the intuitive, menu-driven programming screen
  • Tri-color status LED indicates operational mode, fault & gas presence
  • Two - Analog 4-20mA Relay Outputs
  • Four - Direct Relay Outputs are standard

Specifications
Electrical Characteristics
Voltage+24VDC Nominal (+18 to 32VDC)
Power4.3 W, standby 5.3 W, during alarm
12.0 W with heater on (temp ≤ 30°C)
OutputsAnalog signal: 2x +4-20mA
Digital RS-485 Modbus RTU
HART communication port
Three User Programmed Alarm Relays
One Fault Condition Programmed Relay
Technical Specifications
Humidity0 to 100% relative humidity, non condensing
Operating Temperature-58°F to +167°F (-50°C to +75°C)
-76°F to +167°F (-50°C to +75°C), with heater enabled
Storage temperature-76°F to +185°F (-60°C to +85°C)
Ingress ProtectionIP67
SIL RatingSIL 2, FM/CSA Class I Division 1 certification
Mechanical Characteristics
Material316 Stainless Steel
Conduit Connection5 Conduit Entrances , 3/4” NPT
Dimensions7.50” x 5.60” x 4.28”
Weight12.8 lbs (5.8 kg)
Warranty5 years
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
100-0015-NH3
(4740)

ESP SAFETY  100-0015-NH3

ESP Safety Sensor Assembly, PGU-Ammonia (NH3); Range 0-100ppm; Plug-in sensor & stainless steel housing. Includes weather protective dust cap.



$690.00 
100-0008-SS
(4725)

ESP SAFETY  100-0008-SS

ESP Safety Vector 2-channel gas detector controller . Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. It can be configured with one or two optional sensors, including: Chlorine (Cl2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Hydrogen (H2), Hydrogen Sulfide (H2S), Methane (CH4), Ammonia (NH3), Oxygen (O2), Propane (C3H8) and Sulfur Dioxide (SO2).

Configure

$922.50 
100-0009-01-A
(4724)

ESP SAFETY  100-0009-01-A

ESP Safety UPES 16-channel (4-20mA) gas and flame detector controller, or 128 Modbus digital RS-485 channels (16 ports 8 channels each) for ESP Devices. Includes Modbus RS-485 output port (both analog and digital versions), power supply and 3 alarm relays and audible alert. 3Ux19" modular size, FM & ABS Class I Division 1, Ex CE and IECEx Approved.

Configure

$1,732.50 
> AMMONIA :    42 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$318.40 
BWS1-A_-Y
(6382)

BW  BWS1-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$687.74 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$690.96 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-4824
(6803)

PROSENSE  PC3-4824

Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-4834
(6778)

PROSENSE  P-4834

Prosense P-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$979.29 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$1,086.50 
LBW-50-1-SS
(910)

COOL AIR  LBW-50-1-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$1,176.70 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,217.33 
PQD-4834-1/2
(6739)

PROSENSE  PQD-4834-1/2

Prosense PQD-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109012/0300P-L0
(6908)

RC SYSTEMS  1100ALD-109012/0300P-L0

RC Systems SenSmart 1100 gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,314.28 
LBW-50-RLV
(914)

COOL AIR  LBW-50-RLV

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$1,332.50 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,349.00 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,394.00 
GG-VL2-NH3
(2970)

CALIBRATION TECHNOLOGIES  GG-VL2-NH3

CTI GasGuard NH3 Ammonia Vent Line 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless enclosure.

Configure

$1,434.00 
41001AL-0-1015/0300P/L0
(7158)

RC SYSTEMS  41001AL-0-1015/0300P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,538.96 
51001AL-0-1015/0300P/L0
(7123)

RC SYSTEMS  51001AL-0-1015/0300P/L0

RC Systems SenSmart 5100 3-wire gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.