Honeywell 02104-n-5010 | Combustibles | Open Path | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   02104-N-5010

HONEYWELL 02104-N-5010

DETECTORS / OPEN PATH
COMBUSTIBLES

$11,844.71  [10 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Sieger Searchline Excel Short/Medium/Long range system 120m to 200m complete TX and RX (Transmitter and Receiver) kit. Includes mounting plates, mounting brackets and sunshade, 4-20mA output. UL or CSA approved versions. Optional termination, mounting accessories and XNX transmitter for relay, Modbus, Fieldbus or HART outputs.

02104-N-5010   
11,844.71

Certification
Version
Gas Calibration
Intallation Accessories

   10 Weeks  ]
12 Variants of base SKU

The Searchline Excel is the world’s best selling infrared open path gas detector with over 6,000 units installed in challenging applications throughout industry. From the Arctic Circle to Middle Eastern Deserts, customers have repeatedly selected the Searchline Excel as their preferred choice.

The fundamental design of Searchline Excel has remained the same since its original launch and it continues to lead the field. Other manufacturers have tried unsuccessfully to develop comparable instruments but none have the experience or technology that is utilized in Searchline Excel.

Being in this dominant position has not meant that we have neglected our close relationships with key users. In fact, we have been listening carefully and working together with them to make the best even better! As a direct result of customer feedback Searchline Excel is even easier to align and has the option of an industry standard MODBUS digital output.

Searchline Excel is totally immune to interference from sunlight or any other sources of radiation such as flare stacks, arc welding or lightning.

This is achieved by using a xenon flash lamp that is actually brighter than the sun at the infrared detection wavelengths and solid state detectors with a wide dynamic range.

The lamp is also modulated to have a unique pulse duration and shape. The receiver then uses high speed digital signal processing to validate that all the signals received have this unique signature and rejects any extraneous signals

Why open path gas detection?

Open path detectors compliment the use of individual point detectors and offer many significant benefits including:

  • Wider area coverage - most likely to pick up any leak
  • Very high speed of response
  • NO unrevealed failure modes - no possibility of blocked gas path to detector
  • Detector location not as critical
  • Indicates size of hazard

The multi drop Modbus capability can enable significant savings in installation and cabling costs. A single comms cable can be run between up to 32 detectors instead of the usual ‘home run’ required for each detector. Additionally, the 2 way digital communication protocol allows configuration, warning and fault diagnosis information to be communicated back to the control room. This reduces servicing and maintenance costs as the operator can diagnose the state of any individual unit before deciding to send anyone into the field.

Based on the proven open path design, Searchline Excel Cross-Duct was developed in response to the unique requirements for monitoring in HVAC ducting and Turbine Enclosures.

The Difference

The patented optical design used in Searchline Excel has proven itself as the only solution available that fully addresses all the challenges of open path gas detection. Unlike some competitive devices, it does not try to hide fundamental design inadequacy with the use of software masks that can compromise the unit’s ability to detect gas. Searchline Excel employs a patented double band pass filter that fully compensates for all types of fog and/ or rain thereby allowing it to continue operate accurately and reliably in all climatic conditions.

Applications

  • Offshore platforms & vessels (FPSO’s)
  • Downstream chemical processing plants
  • Gas transport and pipelines
  • Large storage areas & buildings
Features & benefits

  • Fast speed of response provides earliest warning
  • High sensitivity allows low alarm set points
  • Alignment free design makes installation simple
  • Duct flex and vibration tolerance keeps the system online
  • Integral functional gas test facility allows for simple system check
  • Contamination resistant optics reduce the need for unscheduled maintenance
  • Not affected by interference from water vapour
  • Immune to catalytic poisons
  • Works in inert atmospheres

Specification
Available Gases: Methane, Ethane, Propane, Butane, Pentane, Ethylene, Propylene, Ethanol, Methanol.
Range: 0 to 5 LEL.m.
Recommended Alarm Settings: (Low) 1.0 LEL.m; (high) 3.0 LEL.m.
Path Lengths: Short Range 5 to 40m (15 to 130 ft.), Medium Range 40 to 120m (130 to 390ft.) and Long Range 120 to 200m (390 to 650ft.)
Speed of Response: T90 less than 3 seconds. (under normal operating conditions).
Output Signal: 4 to 20mA (maximum loop resistance 600 ohms; source & sink available) and RS485.
21mA Over range.
4 to 20mA Normal operation (0 to 5 LELm).
3mA (1) Dirty optics.
2.5mA (1) Beam blocked.
2mA (1) Inhibit.
0mA Fault.
Digital Output: Modbus RS485 multi drop. Using DVC100(m) or DX100(m).
Operating Temperature: -40 to +65°C (-40 to 150°F).
Operating Humidity: 0 to 99% RH (non-condensing).
Operating Pressure: 91.5 to 105.5 KPa (915 to 1055 mbar) (non-compensated).
Warm-up Time: Less than 5 minutes (operational), or less than 1 hour (fully stabilised).
Power Supply: 18V to 32V dc.
Power Consumption: Short Range TX: 3.5 / 5.0*W maximum. Medium and Long Range TX: 5.5 / 7.5*W maximum. RX: 8W maximum.
Enclosure Material: 316 stainless steel.
Weight (inc. mounting bracket) Short Range TX: 3.5kg. Medium and Long Range TX: 7kg. RX: 3.5kg.
Vibration: 2 to 60Hz, max ptp amplitude 1mm.
Misalignment Tolerance: Short Range ±0.5o (±~35cm at 40m). Medium Range ±0.5a (±~104cm at 120m). Long Range ±0.5o (±~170cm @ 200m).
EMC Standards: EN50270:1999
Performance Approval: FM performance approved.
Safety Approval: ATEX: EExd IIC T5(-40°C to +65°C).
EExd IIC T6(-40°C to +40°C).
II 2G.
UL: Class 1 Div 1 Groups B,C + D and Class 1 Zone 1 AEx d IIB + H2 (Tamb -40°C to +65°C).
CSA: Class 1 Div 1 Groups B,C + D, T5 and Exd IIC T5 (Tamb -40°C to +65°C).
FM: Class 1 Div 1 Groups B,C and D
Other: SAA, GOSST.
Independently assessed to IEC61508
I.P. Rating: IP66 and IP67.
aa aa
aa aa

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
2104N2999
(3278)

HONEYWELL  2104N2999

Searchline Excel Test Filters kit Type B, C, D, E, F, G, H & Manual



$604.45 
XNXUTAINNNNN
(1944)

HONEYWELL  XNXUTAINNNNN

Honeywell XNX Universal Display and Transmitter for IR infrared input compatible with Optima Plus and Excel Open Path sensors, with aluminum alloy LM25 housing (optional stainless steel), 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs, UL, ATEX or INMETRO certified.

Configure

$982.65 
(5822)

HONEYWELL  2992K0088

Searchline Excel installation kit without DX100, include all termination and mounting accessories.



$1,337.47 
2104B2354
(1983)

HONEYWELL  2104B2354

Hand Held Interrogator SHC-1 CSA Certified (4V0 software) for Optima, Optima Plus and Excel



$2,582.33 
02104-N-4006X
(4305)

HONEYWELL  02104-N-4006X

Short/Long Range alignment and conformity kit including telescope, carry case and test filters (no SHC-1 Interrogator) for Honeywell Sieger Searchline Excel & XNX Detectors.

Configure

$2,783.81 
2104B2351
(1982)

HONEYWELL  2104B2351

Hand Held Interrogator UL SHC-1 Certified (4V0 software) for Optima, Optima Plus and Excel



$2,827.47 
02104-N-4006
(4300)

HONEYWELL  02104-N-4006

Short/Long range alignment and conformity kit including SHC-1 handheld interrogator, telescope, carry case and test filters for Honeywell Sieger Searchline Excel Detector. ATEX, UL and CSA versions available.

Configure

$3,562.89 
> COMBUSTIBLES :    3 Items found.
100-002302
(4723)

ESP SAFETY  100-002302

ESP Safety TGAES Open Path Gas Detector for continuos monitoring of combustible hydrocarbon gas concentrations (0-5 LEL/m) (Detects Methane and most common hydrocarbon gases including ethane, propane, butane and propylene). Transmitter and receiver modules. Includes 4-20mA, HART and RS-485 Modbus RTU serial communication outputs. 316 stainless steel enclosures. Tri-color status LED. FM, CSA, CE and IECEx Approved. SIL2 Rated.

Configure

$8,081.25 
QR-QT-C111
(3480)

SPECTREX  QR-QT-C111

Spectrex SafEye Quasar 900 open path IR gas detector, transmitter and receiver, for detection of hydrocarbon gases including alkanes (methane, ethane, propane, butane, pentane, hexane, heptane and octane) and ethylene. Up to 660 ft (200m) path length. Very high speed response. 0-20mA analog output with HART capability. RS485 Modbus. 316L Stainless Steel housing and tilt mounts. IP66 and IP68. FM/FMC, ATEX, IECEx, GOST R and Inmetro approvals, SIL-2. Includes transmitter and receiver.

Configure

$13,997.02 
02104-N-XSAAUS
(4302)

HONEYWELL  02104-N-XSAAUS

Honeywell Sieger Searchline Excel Short/Medium/Long range system 120m to 200m complete TX and RX (Transmitter and Receiver) kit, installation hardware kit, SS316 mounting plates and brackets, 1 junction box Current Source, flex conduit and sunshade. 4-20mA. ATEX approved. Optional XNX transmitter for relay, Modbus, Fieldbus or HART outputs.

Configure

$15,158.40 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.