GAS DETECTORS > ARSINE
GM/EC 2-Wire Gas Monitor with local stainless steel sensor head explosion proof (XP) configured for Arsine (AsH3) with range 0-1 ppm, 4-20 mA output transmitter.
The GASMAX / EC single channel
Toxic / Oxygen gas monitor delivers the
latest in loop-powered gas detection
technology, reliability and ease of use.
The GASMAX / EC is CSA certified for
use in Div 1 & Div 2 explosion proof
installations and intrinsically safe
installations with IS barrier.
The highly visible display shows calibrated engineering values, bar-graph
data, 30-minute trend and setup information. An internal real-time clock
time-stamps calibration and alarm events for later review. Front panel
flashing LEDs continuously indicate alarm conditions.
Operator interface is a menu-driven magnetic keypad, allowing complete setup and calibration without hazardous area declassification.
There are no potentiometers and all adjustments are performed through the magnetic keypad interface.
The GASMAX / EC maintain a record of sensor calibration data that provides an estimate of sensor life remaining. During each post-calibration purge delay, the GASMAX / EC can be programmed to transmit this data on the 4-20mA output.
Locally connected Smart Sensors enhance this capability by maintaining their own electronic record of serial number, born-on date,
initial calibration values, engineering units and other data, ensuring the most accurate measurement and alarming capability available today.
Available Ranges
Options:
- Stainless Steel Enclousure
- ATEX Certified (not available with Aluminum sensor head)
- Wireless 900 MHz
- Certified for use in Explosion Proof and Intrinsically Safe Installations.
- Non-polarized loop powered interface eliminates wiring errors.
- Non-intrusive one-person prompted calibration.
- Smart Sensors store calibration & alarm events.
- Real time clock tags alarm events.
- Aluminum sensor head available for reactive gases.
- See GASMAX II for local relays, LEL or MODBUS®.
Sensor Head Options
- Local Stainless Steel - XP & IS
- Local Stainless Steel (with splash guard) - XP & IS
- Local Aluminum - IS ONLY
- Local Aluminum (with splash guard) - IS ONLY
- Remote Stainless Steel - XP & IS
- Remote Stainless Steel (with splash guard) - XP & IS
- Remote Aluminum - IS ONLY
- Remote Aluminum (w/ splash guard) - IS ONLY
Notes:
- Remote sensor installations do not utilize Smart Sensor interface
- Maximum distance for remote e-chem sensor connection is 25ft (3m).
- Maximun distance for remote LEL sensor connection is 300 ft.
- Highly reactive gases REQUIRE aluminum sensor head and IS in
hazardous area.
Operation and Maintenance Manual of the GasMax Detectors