Gds Gds-48-1-50-06 | Lel Infrared | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GDS-48-1-50-06

GDS GDS-48-1-50-06
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GDS-48 Remote Gas Detector Transmitter with Stainless steel sensor head configured with SmartIR sensor for combustibles and Methane (CH4) 0-100% LEL (Lower Explosive Limit). 3-Wire Bridge Output. CSA Certified for Div. 1 Explosion Proof.

Inquiry

The GDS-48 is a three-wire remote sensor for combustible, carbon dioxide or volatile organic compounds that provides a low impedance bridge-style output suitable for long distance transmission to an appropri- ate receiver device such as a C1 Protector, C2 Protector, C2 Quad Protector Controller or GASMAX II gas monitor.

Wide Variety of Available Sensors

The GDS-48 is compatible with all GDS Corp catalytic bead combustible, SmartIR infrared combustible, SmartIR carbon dioxide and photoionization detectors. Sensors can be easily replaced in the field. Interchangeable catalytic bead and infrared sensors allow users the opportunity to switch between the two technologies with minimal impact to controllers and wiring.

Volatile Organics

In today’s highly regulated environment, monitoring for organic compounds, such as benzene and low level gasoline vapors is critical. The GDS-48 with photoionization detector is available in two ranges, 0-50 ppm and 0-300 ppm isobutylene equivalent.

Rugged Detection

The GDS-48 encloses the sensor in a stainless steel housing with integrated flame arrestor that is CSA approved for all Class I, Division 1 and 2 hazardous environments.

Low Cost Solution

The GDS-48 is designed specifically to work with GDS Corp controllers that provide the necessary excitation voltage and bridge-style interface circuitry, often delivering the the lowest overall cost per point. GDS Corp offers single, dual, four, eight and sixteen channel controllers with compatible bridge-style inputs suitable for final calibration, alarm, display and retransmission of monitored gas values.

Easy Installation

The GDS-48 includes an explosion proof junction box with wiring terminals for easy installation and maintenance. An optional splash guard is recommended for locations where water or liquid may be present.

FEATURES

  • Certified for Class I Division 1 Hazardous Locations
  • Interchangeable catalytic bead and SmartIR combustible sensors for combustible applications
  • SmartIR infrared Carbon Dioxide Sensor for ppm to 100% v/v
  • Photoionization Detector (PID) for Volatile Organic Compounds
  • Three-wire bridge-style interface to GDS Corp controllers
  • Stainless steel enclosure for high noise immunity
  • Low impedance output for long distance cable runs (> 2000ft)
  • Field-replaceable sensor module for easy maintenance
  • Manufactured in USA

GDS-48 SPECIFICATIONS
Power Input: Catalytic Bead: 2.0v @ 300mA (average)
SmartIR Combustible or CO2: 4.5v @100mA (average)
Photoionization Detector: 5v @ 100mA (average)
Display None
Input Accepts bridge-style catalytic bead or SmartIR infrared combustible, infrared carbon dioxide or PID sensors
Calibration Range Calibration function must be performed by remote receiver device
Accuracy Depends on sensor and range
Standard Output Three-wire bridge-style millivolt interface to GDS Corp Display & Alarm Controllers
Temp See sensor limitations
Housing GDS-48 Stainless steel with flame arrestor
Dimensions Width 5.3” x Height 9.3” x Depth 2.75” with splash guard
Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Div. 1 & 2 Groups B, C, D. Suitable for Explosion Proof installations.
Warranty Two years on electronics and one year on sensors from date of purchase

Gases

GAS TYPE SENSOR RANGE COMMENTS
Methane 0 – 5% volume Fully characterised for methane.
Methane 0 – 100% volume Fully characterised for methane
Propane 0 – 2% volume Fully characterised for propane.
Cross-reference factors available for: Butane, Pentane,
Hexane, Ethanol, Ethylene, Propylene, Ethane, Cyclopentane,
Isopropanol, Methanol, Toluene, Acetone, Methyl ethyl ketone
(MEK) and Xylene , see Note 1
Propane 0 – 100% volume Fully characterised for propane
Propylene 0 – 100% volume Fully characterised for propylene
Butane 0 – 2% volume Fully characterised for butane
Pentane 0 – 2% volume Fully characterised for pentane
Hexane 0 – 1% volume Sensor output linearised for hexane, see Note 1
Ethylene 0 – 3% volume Sensor output linearised for ethylene, see Note 1
Ethane 0 – 3% volume Fully characterised for ethane
Ethylen Oxide 0 – 3% volume Fully characterised for ethylene oxide
Ethanol 0 – 5% volume Sensor output linearised for ethanol, see Note 1
Methyl Bromide 0 – 25,000 ppm Sensor output linearised for methyl bromide, see Note 1
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-9550-R06
(262)

GDS  10-9550-R06

Infrared Smart IR LEL Sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,820.78 
> LEL INFRARED :    25 Items found.
P-3033
(6722)

PROSENSE  P-3033

Prosense P-XY35 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$797.94 
PQN-3033-1/2
(6946)

PROSENSE  PQN-3033-1/2

Prosense PQN-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$978.12 
PQD-3033-1/2
(6719)

PROSENSE  PQD-3033-1/2

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,413.89 
100-0008-SS/100-0015-C1
(4756)

ESP SAFETY  100-0008-SS/100-0015-C1

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
100-0001-M11-SS-C1
(4722)

ESP SAFETY  100-0001-M11-SS-C1

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases, Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Division 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Configure

$1,440.00 
OI-6000-IR-LEL-X-R_-DC-C
(6833)

OTIS  OI-6000-IR-LEL-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with infrared sensor for Combustibles 0-100% LEL. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

53001AL-0-9050/100P/L0
(7136)

RC SYSTEMS  53001AL-0-9050/100P/L0

RC Systems SenSmart 5300 3-wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,809.09 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,813.32 
967-215520-100
(2133)

DETCON  967-215520-100

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor

2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$2,123.32 
2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$2,123.32 
33001AL-0-9050/100P/L0
(6898)

RC SYSTEMS  33001AL-0-9050/100P/L0

RC Systems SenSmart 3300 3 wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Division 1 (Explosion Proof).

Configure

$2,181.82 
PIRECLA11A1BT2
(7027)

DET-TRONICS  PIRECLA11A1BT2

Det-tronics PointWatch Eclipse PIRECL Infrared Gas Detector for detection of Hydrocarbons (methane, propane, ethylene, butane) 0 to 100% LFL. Diffusion based. 4-20 mA signal with HART and RS-485 serial communication. Optional relay output. Explosion-proof and stainless steel housing. 24 Vdc. Certified for use in Class I, Divisions 1 and 2. FM, CSA, ATEX, IECEx, DNV/MED, and INMETRO certifications.

GDS-IR-1-110-0
(436)

GDS  GDS-IR-1-110-0

GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Combustibles LEL (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Methane (CH4), Propane (C3H8), Isobutane (C4H10), Pentane (C5H12), Cyclopentane (C5H10), n-Butane (C4H10), Ethanol (C2H6O), Methanol (CH4O), Hexane (C6H14), Jet-A, Diesel and Gasoline.

XNXUTAVNNIF1
(1225)

HONEYWELL  XNXUTAVNNIF1

Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,276.97 
XNXUTAVNNIV1
(2141)

HONEYWELL  XNXUTAVNNIV1

Honeywell XNX Universal Gas Detector Transmitter including MPD-AM1V1 IR Infrared sensor combustible 0-5% Vol 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,380.43 
2108N5100N
(1965)

HONEYWELL  2108N5100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane (Natural Gas), Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit), for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output.

Configure

$2,482.01 
GD10-P00-17DG-0BH
(1868)

SIMTRONICS  GD10-P00-17DG-0BH

Simrad GD10P IR Point Gas Detector for combustible gases: Methane (CH4) , Ethylene (C2H4), Propane (C3H8), Acetylene, Butane and others on offshore installations. 4-20 mA output with HART. 24 VDC. Available Approvals: UL Class I Division 1, ATEX, CSA/US, IECEx, INMETRO, ABS, SIL and MED.

10-0498/100L
(7183)

RC SYSTEMS  10-0498/100L

RC Systems SenSmart 1300M Infrared IR gas detector transmitter for Hydrocarbons 0-100% LEL or %Vol with high performance harsh environment infrared Millenium sensor-transmitter, 4-20mA output, 10-30 VDC, Stainless Steel casing. CSA certified for Class 1 Div 1 (Explosion Proof). Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Gasoline, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$3,422.07 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.