MACURCO TX-12-HS line voltage Gas Detector, controller and transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

TX-12-HS   
656.26

Voltage
Housing Color

   2 Days  ]
2 Variants of base SKU

The Macurco 12-Series are line voltage (100-240VAC), dual relay gas detector, controller and transducers. The 12-Series utilizes an internal switching power supply that is capable of using line voltage between 100 and 240VAC and 50-60Hz. The 12-Series have selectable 4-20mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of various gases and provide feedback and automatic control to help reduce gas concentrations in parking garages, maintenance facilities or other commercial applications.

Selectable options include:
  • Selectable relay actuation levels
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Buzzer, digital display, latching relay, relay delay, relay minimum runtime
Features:
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Supervised system design: detector problem will cause relay activation
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
12-Series Rear View

Specifications:
Power: 100-240VAC (50 TO 60 HZ)
Current: 1.0 A MAX
Shipping Weight: 1 pound (0.45 kg)
Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Color: Dark gray
Connections: plugs/terminals
Mounting box: (not included) 4x4 electri
Fan relay: 5A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation: Selectable within sensor range
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Runtime settings OFF (default), 3, 5, 10 or 15 minutes
Alarm relay: 0.5A 120 V, 60 VA
Alarm relay actuation: selectable N.O. default or N.C.
Alarm relay settings: Selectable within sensor range
Current Loop 4-20 mA
Operating Environment: 0°F to 125° F (-18°C to 52°C).10 to 90% RH
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
CX/TX-CH
(2117)

MACURCO  CX/TX-CH

MACURCO Calibration Hood/cup for CX, TX, OX, & RD series gas detectors: ammonia (NH3), hydrogen sulfide (H2S) and Nitrogen Dioxide (NO2).



$33.38 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
70-2900-0605-4
(2527)

MACURCO  70-2900-0605-4

MACURCO TX-6-HS (TX-12-HS) Hydrogen Sulfide H2S Replacement sensor. (Replaces 26-2900-0006-5)

Configure

$212.16 
Cal-Kit 2*H2S GAS 25PPM
(2997)

MACURCO  Cal-Kit 2*H2S GAS 25PPM

Macurco Macurco Cal-Kit 2 Hydrogen Sulfide (H2S) 25 ppm gas field calibration kit to calibrate Macurco TX-6 fixed gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood. 1/cs. 30-0021-1110-1 & 70-2900-0010-9.



$624.02 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
> HYDROGEN SULFIDE :    38 Items found.
M015-0002-000
(6332)

MPOWER  M015-0002-000

mPower UNI 321 Disposable Single Gas Detector for detection of Hydrogen Sulfide (H2S) 0.1-100ppm. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$108.80 
BWC2-H
(4263)

BW  BWC2-H

BW Clip portable gas detector 2 year maintenance free for Hydrogen Sulfide (H2S). Low alarm set at 5 ppm or 10ppm, High alarm set to 10 ppm or 15 ppm. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

M001-0054-000
(6001)

MPOWER  M001-0054-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Sulfide (H2S) 0-100ppm to 0-1000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$134.40 
BWC2R-H
(5148)

BW  BWC2R-H

BW Clip Real Time portable gas detector with 2 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWC3-H510
(4268)

BW  BWC3-H510

BW Clip portable gas detector 3 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

TX1-2
(5966)

INDUSTRIAL SCIENTIFIC  TX1-2

Industrial Scientific Tango TX1 Gas Detector for Hydrogen Sulfide (H2S) 1-500 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

BWC3R-H
(5152)

BW  BWC3R-H

BW Clip Real Time portable gas detector with 3 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWS1-HL-Y
(6389)

BW  BWS1-HL-Y

BW Solo Serviceable Single-gas Detector for Hydrogen Sulfide (H2S) 0-200 ppm or 0-500 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6424
(6805)

PROSENSE  PC3-6424

Prosense PC3-6424 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with range 0-100 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$514.80 
P-6434
(6775)

PROSENSE  P-6434

Prosense P-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$592.02 
TX-6-HS
(2045)

MACURCO  TX-6-HS

Macurco TX-6-HS low voltage Gas Detector, Controller and Transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$648.99 
SPSTAXH1
(1474)

HONEYWELL  SPSTAXH1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen Sulfide (H2S) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-20 ppm, 0-50 ppm, 0-100 ppm)

Configure

$668.93 
364-455-01-365-756-11100
(6154)

DELPHIAN  364-455-01-365-756-11100

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Sulfide (H2S) 0-25, 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PQN-6434-1/2
(6953)

PROSENSE  PQN-6434-1/2

Prosense PQN-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$772.20 
XT-00H0-Y-NA
(580)

BW  XT-00H0-Y-NA

GasAlertMax XT 4-Gas Detector for H2S ( Hydrogen Sulfide). Monitors up to 4 gas hazards for confined space entry and remote sampling.

OI-6000-EC-H2S-X-R_-DC-C
(6830)

OTIS  OI-6000-EC-H2S-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Hydrogen Sulfide (H2S) 0-100ppm. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

PQD-6434-1/2
(6725)

PROSENSE  PQD-6434-1/2

Prosense PQD-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$926.64 
OI-6000-EC-H2S-X-X-O
(6834)

OTIS  OI-6000-EC-H2S-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Hydrogen Sulfide (H2S) 0-100ppm. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-H2S-50
(4136)

CALIBRATION TECHNOLOGIES  GG-H2S-50

CTI GasGuard H2S Hydrogen Sulfide Electrochemical Sensor (0-50 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
2106B1400
(1451)

HONEYWELL  2106B1400

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen Sulfide (H2S) (0-20 ppm to 0-100 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 