Gds Gds-58bx-0-70-06-15-04/0-0 | Lel Catalytic Bead And Hydrogen Sulfide | Sample Draw | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GDS-58BX-0-70-06-15-04/0-0

SKU# (3347)



GDS GDS-58BX-0-70-06-15-04/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GDS-58BX Dual Channel Sample Draw Monitor with local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit) and Hydrogen Sulfide (H2S). Brushless DC sample pump. Flow status indicator. 24VDC. Includes QVGA TFT Display, two 4-20 mA outputs. Optional relays with MODBUS RTU outputs. Class I Div 1. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others.

DISPLAY   4-20 mA   RELAYS   DIV 1   MODBUS

GDS-58BX-0-70-06-15-04/0-0   
6,595.00

Inlet Filter
Gas Range
Local Relay Option
Mounting Options
Enclosure Options
Tag
Calibration 0-100% LEL
Enclosure heater
Duct mount probe

   3 Weeks  ]
251 Variants of base SKU / 30 Shown below
  • Designed for installation in Class I, Div 1 Hazardous Locations
  • Sensors for CO2, combustible and non-reactive toxic gases
  • High visibility flow indicator shows RED or GREEN status
  • Wiring junction box simplifies field wiring and maintenance
  • Low flow indication on screen and fault interruption of 4-20mA out
  • Built-in flow meter provides visual confirmation of sample flow rate
  • Prompted calibration procedure and cal port for easy maintenance
  • Accepts sample lines up to 500 ft in length
  • Optional programmable 5A relays for low and high alarm indication
  • High quality diaphragm pump with 24VDC brushless motor
  • Optional matching 110/220VAC power supply available
  • Setup in hazardous area requires only simple magnetic wand
  • Manufactured in USA
Remote Sampling Made Easy

The GDS-58BX single or dual channel sample draw system is designed to accurately measure toxic, combustible, or VOC gas levels in areas with limited accessibility or in situations where harsh environmental conditions make the installation of a standard diffusion sensor difficult or impossible. The GDS-58BX combines the new advanced GASMAX BX gas monitor, adjustable flow meter, low flow switch and long life diaphragm pump in a single convenient package.

GASMAX BX Gas Monitor

The GASMAX BX state-of-the-art gas monitor features a high contrast full color display that shows real-time gas values and programmable trend date. High contrast alarm displays draw immediate attention to alarm conditions, and a diffused red/green LED flow indicator shows gas flow status at a glance. An internal real-time clock and event log time-stamps calibration and alarm events for later review.

Optional alarm relay and serial MODBUS port are available in addition to standard single or dual 4-20mA output.

The GDS-58BX supports all current GASMAX BX sensors, including electrochemical, photoionization or SmartIR infrared sensors. An easy-to-use menu-driven operator interface eliminates all analog potentiometers and allows setup and calibration to be completed without hazardous area declassification.

An integrated Run / Calibrate valve and user prompted calibration procedure make routine maintenance and field ‘bump tests’ quick and easy.

Rugged and Reliable

The GDS-58BX Sample Draw system is designed for installation and use in industrial applications and hazardous areas rated Class I, Div 1. Temperature- compensated sensors and industrial- quality components allow reliable operation and rapid response down to -20°C (max low temperature depends on selected sensor).

The GDS-58BX is ideal for sampling toxic or combustible gases in:The GDS-58BX is ideal for sampling toxic or combustible gases in:
  • Sumps and enclosed areas
  • Cabinets or storeroom with limited ventilation or airflow
  • Air conditioning intake or exhaust plenums and ducts
  • Boiler burners and ducting

GDS-58BX SPECIFICATIONS
Power Input: 24VDC +/- 5% at < 10 watts.
Display Sunlight-readable full color QVGA TFT display with value, bargraph and trend graph screens
Sensor Options Electrochemical sensors for toxic gases
Electrochemical sensors for oxygen deficiency
PID sensors for detection of volatile organic compounds
SmartIR infrared sensors for detection of methane, propane or carbon dioxide in ppm and % by volume
GDS-IR & IR2 sensors for a wide range of combustibles
Standard Output Dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Bright LED red / green flow status indicator panel. Shows green if flow OK, red if flow blocked.
Wiring Junction Box with Power On indicator, easy-connect wiring terminals and two 3/4” NPT female connections
Optional Output Single 5A relay connections (NO, COM, NC) plus single RS-485 2-wire MODBUS slave interface.
Sample Pump 1.6L diaphragm pump with brushless 24VDC motor
Temp -20°C to +55°C operating. Minimum and maximum operating temperature is dependent on sensor selected.
Housing Aluminum housing with epoxy paint #316 stainless optional
Dimensions 16” x 12” x 5” for sensor types 10 - 70, 10 pounds 16” x 15” x 5” for sensor types 110+, 14 pounds
Stainless steel plate, 21” x 21”, 22 pounds
24” x 24” nonmetallic enclosure, 40 pounds
Inlet / Outlet 1/4” compression, stainless steel
Approvals All components rated for Class I, Div 1 hazardous areas. Suitable for XP installations (may require GDS-IR or GDS-IR2 sensors)
Warranty 2 years from date of purchase on electronics
GDS-58BX SPECIFICATIONS
Power Input: 24VDC +/- 5% at < 10 watts.
Display Sunlight-readable full color QVGA TFT display with value, bargraph and trend graph screens
Sensor Options Electrochemical sensors for toxic gases
Electrochemical sensors for oxygen deficiency
PID sensors for detection of volatile organic compounds
SmartIR infrared sensors for detection of methane, propane or carbon dioxide in ppm and % by volume
GDS-IR & IR2 sensors for a wide range of combustibles
Standard Output Dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Bright LED red / green flow status indicator panel. Shows green if flow OK, red if flow blocked.
Wiring Junction Box with Power On indicator, easy-connect wiring terminals and two 3/4” NPT female connections
Optional Output Single 5A relay connections (NO, COM, NC) plus single RS-485 2-wire MODBUS slave interface.
Sample Pump 1.6L diaphragm pump with brushless 24VDC motor
Temp -20°C to +55°C operating. Minimum and maximum operating temperature is dependent on sensor selected.
Housing Aluminum housing with epoxy paint #316 stainless optional
Dimensions 16” x 12” x 5” for sensor types 10 - 70, 10 pounds 16” x 15” x 5” for sensor types 110+, 14 pounds
Stainless steel plate, 21” x 21”, 22 pounds
24” x 24” nonmetallic enclosure, 40 pounds
Inlet / Outlet 1/4” compression, stainless steel
Approvals All components rated for Class I, Div 1 hazardous areas. Suitable for XP installations (may require GDS-IR or GDS-IR2 sensors)
Warranty 2 years from date of purchase on electronics

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer/Electronic Payment and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 100 Liter Aluminium Cylinder.

1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 100 Liter Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Div 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20 mA input channels board.

Configure

$3,525.97 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.