       Worldwide Shipping Ask About Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA     Español Detectores de gas para Latinoamerica
281­-643­-0080
Call Us! 9am-5pm CST
         
Gas leak detectors, analyzers, alarm devices and calibration gas
PRODUCTS & SERVICES
Legal Exposure Limits
[ NIOSH Exposure Limits ]


Federal Government Contractor
(SAM) CAGE Code: 4W5M0

Why GasDetectors.com ?

  • GasDetectorsUSA.com provides a wide range of industrial gas detection systems including toxic, oxygen and combustibles, truly "state of the art" devices offering unparalleled features and capabilities along with Hazardous Area, Explosion Proof, UL, Atex and CSA certifications at a reasonable price. We also offer gas detection solutions with PLC & SCADA.

  • Our Broad spectrum of skills, experience and hands-on approach ensures the success of Your project
  • We provide specialized products, services or turnkey projects, to suit your needs in
    • Fixed gas detectors.
    • Portable gas detectors.
    • Multi-Point gas controllers.
    • Calibration Gases.
    • Alarm Signal Devices.
    • Installation and commissioning.
    • PLC-based gas detection solutions.
    • Data acquisition and SCADA.


Houston, TX USA

SKU#(3074) Be the First to Review this Item

SIERRA MONITOR  5100-06-IT-A1-01-0-0

DETECTORS / GAS DETECTORS
CHLORINE

$1,616.00     Availability: 3 Weeks
 Information Request
 Shipping Rates
 Volume discount
      



SIERRA MONITOR 5100-06-IT-A1-01-0-0
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Documents

Sierra Monitor 5200-06-IT Toxic Gas Leak Detector for Chlorine (Cl) 0-10ppm Electrochemical Sensor. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

Part# with Options:        5100-06-IT-A1-01-0-0
Price with Options:        1,616.00

Options:    

Rainshield
(1) Rainshield for Sierra Monitor 5100
Enclosure
(2) Enclosure for Sierra Monitor 5100
Output
(3) Relay/Connection Output for Macurco 5100
Sensor Protection
(4) Sensor Protection for Sierra Monitor 5100-XX (Toxic)
For very humid, marine and military applications.
Remote Sensor Kit
(5) Remote Sensor Kit for Sierra Monitor 5100

  Availability 3 Weeks  ]

Information Technology (IT) at the component level! A network enabled Gas Sensor Module with the brilliance to provide Sentry, 4-20 mA or Modbus output. This is a stand alone module with the intelligence to provide integral alarms, loaded with features you need. A gas detector with a Sierra Monitor pedigree, Factory Mutual approved and ready to manage your gas risk. The 5100-XX-IT Series provides all the built-in features desired by instrumentation and safety professionals, including:

  • FM Approval for performance and safety
  • 180 day calibration frequency
  • SIL-2 Certified
  • Modbus RTU RS-485 interface
  • 4-20 mA output
  • HART Interface
  • SMC Sentry digital bus interface
  • ATEX Approved (5100-05-IT)
  • IECEx Certified (5100-05-IT)
  • Optional Integral alarm relays – Alarm, Warning and Trouble
  • Aluminum or 316 Stainless Steel enclosure
  • Integral scrolling LED display
  • Remote alarm reset
  • Optional remote sensor

The 5100-XX-IT can be used as a 4-20 mA component or as a Modbus RTU node. For higher level system capabilities the module can interface directly to Sierra Monitor’s Sentry Controller. As part of a Sentry system the user gains capability of system Modbus serial communications, extensive diagnostic features, area and zone alarm management, WebServer interface and multiplexing sensor connections.

Factory Mutual (FM) Approved for electrical safety and environmental parameters including Class I, Div. 1, Groups B, C, D and Class I, Zone 1, Group IIB+H2 IP66. The 5100-XX-IT is also SIL Certified and meets NFPA-72 requirements for gas detectors.

Electrochemical sensors are fuel cell-like devices consisting of an anode, cathode and electrolyte. The components of the cell are selected so a subject gas, allowed to diffuse into the cell, will cause a chemical reaction and generate a current. The cells are diffusion limited so the rate the gas enters the cell is solely dependent on the gas concentration. The current generated is proportional to the rate of the consumption of the subject gas in the cell.

Features

  • Local scrolling display
  • Non-intrusive calibration, menu driven system
  • FM Approved for performance and hazardous area operation, Class I, Div. 1, Group B, C, D, with NEMA 4X enclosure rated for -40 o to 122 o F areas
  • Flexible Modbus, 4-20mA, Sentry bus, HART and relay interface
  • SIL-2 Certified

Benefits

  • Easy to install in a variety of field applications plus easy to obtain critical safety information wherever needed
  • Able to easily and quickly calibrate module without declassifying the area
  • For safe and reliable operation in hazardous areas 5100-05-IT also includes FM Approval for performance
  • Easy to install in a variety of field applications plus easy to obtain critical safety information wherever needed
  • Meets long term reliability design standards

Specifications:
Sensor type: Electrochemical
Performance
Range: Default range as above User selectable alternative ranges)
Sensor Life: Typically >2 years
Output
Display: Fixed and Scrolling LED
Signal Output: Sentry digital bus
Analog 4-20 mA
3-wire Non-Isolated
4-wire Isolated
Serial RS-485 Modbus RTU
Relay: Optional
Options
Relays: 5 amp Alarm, Warning (0.25 amp Trouble)
5A@ 250 VAC, 5A@ 30VDC (Alarm, Warning)
Board includes auxiliary connection for Sentry multiplexing
HART: Termination board includes HART, Modbus RS-485, 4-20mA, Digital Input, 2A Relay output, No Sentry Bus
Power
Power consumption: 2 watts maximum
Input voltage: 24 VDC nominal: 10-30VDC
Construction
Dimensions: (A1 & A2): 7.9 x 5.7 x 3.9 in. (20.1 x 14.5 x 9.9 cm)
(S1 & S2): 7.6 x 4.4 x 4.9 in. (19.3 x 11.2 x 12.4 cm)
Weight: (A1 & A2): 3.4 lb. (1.5 Kg)
(S1 & S2): 7.2 lb. (3.3 Kg)
Housing: Epoxy-coated, die-cast, copper-free Aluminum or 316 Stainless Steel
Rating: Explosion proof, Class 1, Div. I, Groups B, C, D Group IIB + H2 IP66, IP65, NEMA 4X
Warranty: 2 years
Approvals: FM, CSA for enclosure in hazardous locations
FM Performance Approval (5100-05-IT)
SIL-2 Certified (5100-04-IT, 5100-05-IT, 5100-06-IT)
ATEX Certified II 2 G Ex d IIB+H2 T6 Gb
Ta = -20 C to +50 C (5100-05-IT)
IECEx Certified (5100-05-IT)
CE Mark (5100-05-IT)
ABS (5100-05-IT)
CQST Certified for China (5100 -03, -04, & -05 -IT)
CCOE/PESO Certified for India
Gas Specifications:
Gas type Std. Range Opt. Max Range Resolution Response Time Accuracy Operating Range (F)
Oxygen 5-25 %Vol 25 %Vol 0.1% <10 sec. +/- 0.2% - 4 to 122
Carbon Monoxide 0-500 PPM 1200 PPM 0.5 PPM <35 sec. +/- 1 PPM - 4 to 122
Hydrogen Sulfide 0-100 PPM 100 PPM 0.1 PPM <35 sec. +/- 3 PPM - 40 to 122
Chlorine 0-10 PPM 10.0 PPM 0.1 PPM <60 sec. +/- 0.5 PPM - 4 to 122
Chlorine Dioxide 0-3 PPM 3.0 PPM 0.1 PPM <60 sec. +/- 0.5 PPM - 4 to 122
Sulfur Dioxide 0-100 PPM 100 PPM 0.5 PPM <20 sec. +/- 0.5 PPM - 4 to 122
Nitrogen Dioxide 0-20 PPM 20 PPM 0.2 PPM <35 sec. +/- 0.5 PPM - 4 to 122
Hydrogen Chloride 0-20 PPM 20 PPM 0.1 PPM <100 sec. +/- 0.1 PPM - 4 to 122
Ammonia 0-100 PPM 100 PPM 1.0 PPM <30 sec. +/- 1 PPM - 14 to 113
Hydrogen Fluoride 0-10 PPM 10 PPM 0.5 PPM <30 sec. +/- 1 PPM - 14 to 113


  • SENSORS (REPLACEMENT) > SIERRA MONITOR
    5200-06-IT Sierra Monitor 5200-06-IT replacement sensor for Chlorine (Cl2) 0-10 ppm. Electrochemical Sensor. ..


B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > CHLORINE :    13 Items found.
SPSTAXL1 (1482) HONEYWELL  SPSTAXL1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Chlorine (Cl2) 0-5ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-5 ppm, 0-15 ppm)

  

$522.43        

 
2106B1410 (1456) HONEYWELL  2106B1410

Honeywell Sieger Sensepoint Gas Detector Transmitter for Chlorine (Cl2) (0-5 ppm to 0-15 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

  

$736.33        

 
GDS-49-3-12-02 (160) GDS  GDS-49-3-12-02

GDS GDS-49 Remote Gas Detector Transmitter with stainless steel sensor head (non-XP) configured for Chlorine (CL2) with range 0-5 to 0-50 ppm. 2-Wire 4-20 mA transmitter.

  

$885.00        

 
SPXCDULNL2 (1898) HONEYWELL  SPXCDULNL2

Honeywell XCD Sensepoint Gas Detector, Chlorine (Cl2) RDT Remote Electrochemical Sensor with Epoxy painted aluminium alloy LM25 housing, stainless steel sensor head, explosion-proof IP66, provides comprehensive monitoring of Chlorine (Cl2) gas hazards in potentially explosive atmospheres, both indoors and outdoors. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 0.0 to 5.0ppm UL/CSA Class I Division 1 or ATEX IECEx available.

  

$1,069.98        

 
TM-EC-48-12-02-0 (3387) GDS  TM-EC-48-12-02-0

GDS TRANSMAX EC Loop-Powered Gas Monitor with stainless steel sensor head and integrated sensor configured for Chlorine (Cl2) for range 0-5 to 0-50 ppm. 2-wire 4-20mA current sink output and large LCD Display. Polycarbonate housing (IP66/IP67).

  

$1,150.00        

 
S3KUL2-XNXXSL1SS (687) HONEYWELL  S3KUL2-XNXXSL1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum alloy LM25 housing for monitoring of CHLORINE (CI2) gas hazards in potentially explosive atmospheres, both in and out of doors using electrochemical sensing technology. Operates on an industry standard 2-wire 4-20mA loop, 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

  

$1,142.64        

 
TMII-48-12-02/00-00-00/0-0 (149) GDS  TMII-48-12-02/00-00-00/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head (non-XP) with integrated sensor configured for Chlorine (Cl2) for range 0-5 to 0-50 ppm with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

  

$1,275.00        

 
GM/EC-03-12-02 (118) GDS  GM/EC-03-12-02

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter.

  

$1,435.00        

 
GMII-03-012-02/00-000-00/0-0 (136) GDS  GMII-03-012-02/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

  

$1,605.00        

 
XNXUTAENNNNN-XNXXSL1SS (837) HONEYWELL  XNXUTAENNNNN-XNXXSL1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring of Chlorine (Cl2) 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm) compatible with all Honeywell gas sensing technologies, with aluminum alloy LM25 housing. Operates on an industry standard 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

  

$1,487.42        Part # XNXUTAENNNNN-XNXXSL1SS

 
100-0008-A1/100-0015-Cl2 (4750) ESP SAFETY  100-0008-A1/100-0015-Cl2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In Sensor to Detect Chlorine (Cl2) 0-10ppm. Operates as a stand-alone display for a variety of ESP detectors which can be remotely located up to 500 feet away. Sensor head can also be attached. Includes analog 4-20 current loop w/HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. Explosion-proof housing. IP67. SIL certification.

  

$1,401.60        

 
C2-22-012-02/00-000-00/0-0-0-0-0/0-0 (366) GDS  C2-22-012-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local DELRIN sensor head with integrated Chlorine (Cl2) sensor with range 0-5 to 0-50 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

  

$2,350.00        

 
45-43-310-68-09-665 (2507) DRAEGER  45-43-310-68-09-665

Draeger PointGard® II microprocessor based gas detector for continuous monitoring of Chlorine (Cl2) in ambient air, range 0 to 5/10/20/50 ppm. Designed to be astand-alone instrument that is easy to use. NEMA 4X plastic enclosure, easy-to-read LED display, audible and visual alarm indicators and up to 100dB Horn. Furnished with a 3-prong line cord for standard wall outlet. Two alarm relays, one fault relay.

  

$2,398.71        

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
5100-06-IT-A1-01-0

Industrial Automation Services
Industrial Automation Services with PLC and SCADA


Previous Button
Next Button

 


| My Orders | Imprint | Terms and Conditions | Contact Us | Get a Quote | Downloads | Sell Here | Mobile View Mobile view |   LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to GasDetectorsUSA.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform
  • Customer relationship management (CRM) tools
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Multi-Store
  • Mobile Site
|