Honeywell Xcdrfdl | Lel Catalytic Bead | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   XCDRFDL

HONEYWELL XCDRFDL
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Sensepoint XCD RFD (Remote Flammable Detector) Kit. Includes transmitter with LM25, 3/4“NPT Entry, 705 sensor, and 3 wire junction box. Tri-colour backit display. Outputs include 2 programmable alarm relays, 1 programmable fault relay, 4-20mAoutput (sink or source selectable). Sensor can be mounted up to 30 metres (100 feet) from transmitter. cCSAus Certified for North America. Class 1, Div 1, Groups B, C, & D.

XCDRFDL   
1,734.98

Enclosure
Modbus
Sensor
Calibration 0-100% LEL
Custom Tag

   4 Weeks  ]
2 Variants of base SKU

Sensepoint XCD RFD (Remote Flammable Detector) has been specifically designed for use with remotely mounted flammable gas sensors. This configuration is ideal for applications where the sensor is required to be mounted remotely from the transmitter in areas where temperatures are well above ambient (up to 150°C/302°F), or that are difficult to access. The transmitter can be mounted at a suitable location away from this area where it is easy to access, view its display and interact with via the user interface.

Applications

  • Compatible with high temperature sensors for use in and around Gas Turbine Enclosures and solvent based printing and coating drying ovens
  • Compliant with the requirements of HSE guidance note PM84
  • Transmitter can be mounted in easy to access area even if sensor is in a hard to access or restricted access area
  • Sensor can be mounted up to 30 metres (100 feet) from transmitter
  • Standard temperature catalytic and infrared sensor types also available
Reliable detection

  • Compatible with Honeywell Analytics’ proven catalytic bead flammable gas sensors
  • High temperature gas sensors have thermally matched beads for highest accuracy and stability enabling low alarm levels
  • Gas sensors use long life, poison resistant beads as standard, reducing ongoing cost of ownership
Easy to Use

  • Easy to read tri-colour backlit display with digits, bar graph and icons
  • Fully configurable via non-intrusive magnetic switches
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance prevents false alarms
Cost Effective

  • Sensepoint XCD common transmitter platform
  • Reduces training costs
  • Reduced spares and stock costs
  • Non-intrusive, one-man operation reduces cost of maintenance
  • Optional Sensepoint XCD plug-in sensor reduces maintenance time further

Sensepoint XCD RFD is suitable for use with several Honeywell Analytics’ sensors; the Sensepoint XCD catalytic bead and infrared type plug-in sensors and the Sensepoint standard and high temperature sensors. These sensors can be mounted up to 30 metres (100 feet) away from the transmitter thereby accommodating even the most remote and inaccessible applications.

The gas range is user adjustable at the transmitter from 0-100%LEL down to 0-20%LEL. The 0-20%LEL range is particularly suited for use with the Sensepoint high temperature sensors that have thermally matched beads providing optimum accuracy and stability allowing alarm set points as low as 5%LEL.

The transmitter’s tri-colour backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

Outputs include 2 programmable alarm relays, 1 programmable fault relay as well as 4-20mA output (sink or source selectable). The range, relay operation, alarm set points and electronic tag number of the detector can be adjusted using the transmitter’s LCD and the non-intrusive magnetic switches.

Outputs are automatically inhibited during adjustment thereby reducing the risk of false alarm at the control panel during maintenance.

The Sensepoint XCD Remote Flammable Detector (RFD) can be used with Sensepoint XCD remote flammable sensors (Catalytic and IR), or with the Sensepoint range of flammable gas detectors. The sensors can be directly mounted to the M25 entry at the bottom of the transmitter, or remotely mounted to suitable junction boxes or duct mounting assemblies. Sensepoint flammable detectors are available in both standard and high temperature versions.

Sensepoint XCD RFD uses three instantly recognisable ‘traffic light’ colours to indicate its status. The large tri-colour backlit LCD flashes red to indicate an alarm, flashes yellow to indicate a fault and is steady green to indicate normal operation. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number o

Sensepoint XCD RFD Transmitter
Use 3 wire 4-20mA gas transmitter for use with remotely mounted flammable gas detectors to protect plant and personnel from flammable gas hazards. Transmitter incorporates in-built alarm and fault relays, local tri-colour LCD display and is fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 18 to 32VDC (24VDC nominal)
Max Power Consumption 5 Watts
Current Output Sink or source
≥0.0<1.0mA Fault
2.0mA or 4.0mA Inhibit (during configuration/user settings)
4.0mA to 20.0mA Normal gas measurement
22.0mA Maximum over range
Terminals 18 x screw terminals suitable for wire diameter 0.5mm 2 to 2.5mm 2 (20AWG to 14AWG)
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energised de-energised (programmable)
Alarm relays default normally open/de-energised. Fault relay default normally open/energised
Construction
Material Transmitter Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: Sensepoint XCD plug-in sensor and Sensepoint High Temperature sensor: 316 stainless steel. Sensepoint Standard Sensor: PPS
Weather Protection: Plastic
Weight (approx) Aluminium Alloy LM25: 2.0kg (4.4lbs)
316 Stainless Steel: 5.0kg (11lbs)
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts
Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Entries European ATEX/IECEx versions: 2 x M20 side entries and 1 x M25 bottom entry. Suitable blanking plug supplied for use if only 1 side entry used. Seal to maintain IP rating
Certification
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
China GB Ex d IIC T4 GB3836.1&2 -2000, PA, CCCF
Korea KTL Ex d IIC T6 (-40°C to +65°C)
EMC CE: EN50270:2006 EN6100-6-4:2007
Environmental
IP Rating IP66 in accordance with EN60529:1992
Transmitter Certified Operating Range -40oC to +65oC (-40oF to +149oF)
Note: The detector display may become illegible at temperatures below -20°C, but the detector continues its gas monitoring function. The display is not damaged and recovers when the temperature rises back above -20°C.
Operating Humidity Continuous 20-90%RH (non-condensing), Intermittent 0-99%RH (non-condensing)
Operating Pressure 90-110kPa
Storage Conditions -25°C to +65°C (-13°F to 131°F)
Transmitter Ordering Information
Standard Supply Sensepoint XCD RFD is supplied complete with integral wall mounting plate, 2 x M20 side entries and 1 x M25 bottom entry. 1 x M20 plug, Allen key for locking screw, operating magnet, quick start guide and instruction manual CD. Default settings, ranges and calibrations are 100% tested at the factory. Each unit is supplied with a test certificate.
Shipping Details Shipping carton dimensions: L312mm (12.3”) x W223mm (8.8”) x D110mm (4.3”) Approximate weight: aluminium 2.5kg (5.5lbs), stainless steel 5.5kg (12.1lbs)
Detectable Gases and Sensepoint XCD RFD Sensor Performance
Gas Selectable Full Scale Range Default Range Steps Selectable Cal Gas Range Default Cal Point Response Time (T90) Secs
Sensepoint Standard Temperature Sensor 25 to 95% of selected full scale range
Flammable 1 to 8* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <25
Sensepoint High Temperature Sensor
Flammable 1 to 8* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <10
Plug-in Sensepoint XCD Catalytic Bead Sensors
Flammable 1 to 8* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <25
Plug-in Sensepoint XCD Infrared Sensors 30 to 70% of selected full scale range
Methane 20 to 100%LEL 100%LEL 10%LEL 50%LEL <30
Propane* 20 to 100%LEL 100%LEL 10%LEL 50%LEL <30
Carbon Dioxide* 2.00%Vol. 2.00%Vol. n/a 50%LEL <30
Detectable Gases and Sensepoint XCD RFD Sensor Performance
Gas Accuracy Min Operating Temperature Max Operating Temperature A1 Default Alarm Point A2 Default Alarm Point
Sensepoint Standard Temperature Sensor
Flammable 1 to 8* <+/- 1.5%LEL -55°C / -67°F 80°C / 176°F 20%LEL ▲ 40%LEL ▲
Sensepoint High Temperature Sensor
Flammable 1 to 8* <+/- 1.5%LEL -55°C / -67°F 150°C / 302°F 20%LEL ▲ 40%LEL ▲
Plug-in Sensepoint XCD Catalytic Bead Sensors
Flammable 1 to 8* <+/- 1.5%LEL -40°C / -40°F 65°C / 149°F 20%LEL ▲ 40%LEL ▲
Plug-in Sensepoint XCD Infrared Sensors
Methane <+/- 1.5%LEL -20°C / -4°F 50°C / 122°F 20%LEL ▲ 40%LEL ▲
Propane* <+/- 1.5%LEL -20°C / -4°F 50°C / 122°F 20%LEL ▲ 40%LEL ▲
Carbon Dioxide* <+/-0.04%Vol. -20°C / -4°F 50°C / 122°F 0.40%V/V. ▲ 0.80%V/V. ▲

*Contact Honeywell Analytics for availability

Export Info
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    21 Items found.
SPXCDMTBR
(3005)

HONEYWELL  SPXCDMTBR

Honeywell Pipe Mounting bracket (inc. fixings and hex wrench set)



$104.72 
02000-A-1635
(1470)

HONEYWELL  02000-A-1635

Honeywell Weather Protection Housing with calibration port / calibration cup for XNX MPD sensors



$110.94 
CYL-10241000
(4296)

PORTAGAS  CYL-10241000

Calibration Gas Ethane (C2H6) 50% LEL 1.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10305400
(3238)

PORTAGAS  CYL-10305400

Calibration Gas Hexane 40% LEL (4400 ppm) Balance Air Size 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder (Made by Portagas)

Configure

$124.51 
CYL-90302139
(1259)

PORTAGAS  CYL-90302139

Calibration Gas Butane (C4H10) 50% LEL (0.9%) Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10624200
(1305)

PORTAGAS  CYL-10624200

Calibration Gas Propane (C3H8) 50% LEL 1.06%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90090227
(1313)

PORTAGAS  CYL-90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095187
(6713)

PORTAGAS  CYL-90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90301910
(933)

PORTAGAS  CYL-90301910

Calibration Gas Hydrogen (H2), 50% LEL 2% vol Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90411390
(2927)

PORTAGAS  CYL-90411390

Calibration Gas Hydrogen (H2) 60% LEL 2.4% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095251
(2040)

PORTAGAS  CYL-90095251

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095224
(2926)

PORTAGAS  CYL-90095224

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
02000-A-1642
(1882)

HONEYWELL  02000-A-1642

Honeywell Collecting Cone (for use with MPD, Sensepoint and 705 sensors)



$132.71 
02000-A-1640
(1471)

HONEYWELL  02000-A-1640

Honeywell Nylon Weather Protection for Combustible/MPD, Sieger, Zareba Sensepoint, XCD, RTD, RFD, 705, XNX Combustible Sensors with test/calibration gas port.



$133.75 
(2512)

HONEYWELL  00780-A-0076

Honeywell Weather Protection Stainless Steel for 705 HT



$319.33 
2441-0022
(1969)

HONEYWELL  2441-0022

Honeywell UL/CSA Aluminum 6 wire Junction Box 3/4" NPT entries, can be used for remote sensors with 3/4" NPT male threads, can be used with MPD sensors.



$362.88 
(3008)

HONEYWELL  00780-A-0035

Honeywell Calibration Cup Gas Flow Adaptor (for use with 705 sensors)



$362.88 
(3006)

HONEYWELL  SPXCDSDP

Honeywell Sunshade / Deluge Protection.



$402.28 
00705-A-1733
(3001)

HONEYWELL  00705-A-1733

Honeywell 705 Combustible Sensor. Aluminum. Catalytic Bead (SG16B) 0-100% LEL.



$622.08 
(3007)

HONEYWELL  1283-1047

Honeywell Duct Mount Adaptor Assembly for Duct Mounting XCD-RTD, XCD-RFD, Sensepoint Toxic, Sensepoint Combustible, 705 and XNX w/70



$744.42 
Page: 1 | 2 | All
> LEL CATALYTIC BEAD :    27 Items found.
GD-2B
(2047)

MACURCO  GD-2B

Macurco GD-2B Gas Detector for combustibles (heating type gases). Low voltage and designed for connection to Fire Alarm/Burglary Control Panels. 9-32 VDC or 12-24 VAC input. Meets UL 2075 standard. Alarm, trouble relays and 85dB buzzer.



$117.91 
GD-2A
(650)

MACURCO  GD-2A

MACURCO Combustible Gas Detector low voltage all-electronic monitor engineered to detect heating type gases, including methane (natural gas) and propane(bottled gas). 12-24 VAC or VDC input. SPDT alarm and NC trouble relays. Listed to UL Standard 2075. CSFM Approved.



$117.91 
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$231.66 
P-3012PEK
(6800)

PROSENSE  P-3012PEK

Prosense P-XY12PEK Gas Detector with Catalytic Bead and Motion sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
P-5535
(6774)

PROSENSE  P-5535

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
GD-6
(1234)

MACURCO  GD-6

MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$481.90 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$482.11 
GD-12
(3416)

MACURCO  GD-12

MACURCO GD-12 line voltage Gas Detector, controller and transducer for Combustibles (EX) 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$494.01 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$575.52 
PQN-5535-1/2
(6950)

PROSENSE  PQN-5535-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQN-3035-1/2
(6947)

PROSENSE  PQN-3035-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQD-3035-1/2
(6718)

PROSENSE  PQD-3035-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$772.20 
PQD-5535-1/2
(6736)

PROSENSE  PQD-5535-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$772.20 
2106B2310
(1640)

HONEYWELL  2106B2310

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Configure

$855.75 
OI-6000-CB2-LEL-X-X-O
(6836)

OTIS  OI-6000-CB2-LEL-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with catalytic bead sensor for Combustibles 0-100 % LEL. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$1,145.00 
1200ALD-109070/100P-L0
(6903)

RC SYSTEMS  1200ALD-109070/100P-L0

RC Systems SenSmart 1200 gas detector for Hydrocarbons and Hydrogen, Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-48' smart transmitter. 3-Wire Bridge Output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,218.18 
SPXCDULNFX
(658)

HONEYWELL  SPXCDULNFX

Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (LNG-natural gas), Propane C3H8 (LPG), Butane C4H10, Pentane, Hexane, Ethanol, Hydrogen with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,373.95 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.