Calibration Technologies Gg-r22-0500 | Refrigerants | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-R22-0500

CALIBRATION TECHNOLOGIES GG-_R22-0500
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GasGuard R Refrigerant Infrared Sensor for R22, R134a, R401a, R402a, R404a, R407a, R407c, R422d, R434a and R507a. (0-500 or 0-3000 ppm) for gas leak detection in refrigeration systems, food processing areas, bottling plants and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

GG-R22-0500
1,519.00

Refrigerant Gas
Gas Range
Relay Output
RM420 Relay Output

   In Stock  ]


Key Features

  • R22, R134a, R404a, R507a and other refrigerant gases detected
  • Gas-specific infrared sensor technology – no false alarms
  • Industry standard linear 4/20 mA output
  • Corrosion, weather and chemical resistant sensor enclosure
  • Sensor designed to adapt to any harsh environment from -50°F to +120°F
  • Real-time continuous monitoring
  • 0-500 ppm and 0-3,000 ppm ranges available
  • Self-diagnostics of sensor elements for fail-safe operation
  • Meets California Air Resources Board specifications with 0-500 ppm range

The GasGuard R utilizes proven infrared sensor technology for fast and accurate leak detection. With no moving parts and no cells to replace, the GasGuard R provides real-time continuous monitoring and inexpensive long-term operating costs.

The GasGuard R is refrigerant gas specific, so false alarms from floor cleaners and food off-gasing is non- existent. The output signal is also not affected by EMI/RFI, moisture or drastic temperature variations such as washdowns, defrost cycles, etc.

The GasGuard R provides an industry standard linear 4/20 mA output signal compatible with most gas detection systems and PLCs. The high-quality polycarbonate enclosure offer excellent chemical corrosion protection and high impact resistance.

Applications

  • Refrigeration Systems
  • Food Processing areas
  • Perimeter Monitoring
  • Bottling Plants
  • Breweries
  • Ice Rinks
  • Supermarkets
  • Rack Houses
  • Compressor Rooms
  • Pharmaceuticals
  • Sea Vessels
Benefits

  • Extremely long life
  • Low cost of ownership
  • Simple operation
  • Rugged and reliable
  • Versatile for any application

The standard GasGuard R sensor comes equipped with a corrosion proof enclosure and adaptive temperature control, and is designed to work anywhere. With only one sensor for any application, designing, ordering and maintaining your refrigerant monitoring system is less hassle. The 0/500 ppm model provides the highest accuracy and lowest leak detection ability, starting at 10 ppm, to meet the California Air Resources Board specifications.

The GasGuard R is available for two different target gas classes. The R8 model operates at approximately 8 microns wavelength and detects R134a, R404a, R410a, R507a and other HFC gases. The R9 model operates at approximately 9 microns wavelength and detects R22, R11 and other CFC/HCFC gases.

The GasGuard R is prepared to survive in just about any harsh industrial condition. The adaptive temperature control system allows it to automatically adjust to extreme temperature fluctuations. Every sensor circuit board is sealed forever in potting compound, protecting electronic components and copper tracing from corrosion. A specially vented chemical- resistant polycarbonate enclosure protects the sensor from accidental damage, weather and even direct hose-hits from clean-up crews.

Specifications
DETECTION PRINCIPLE: (NDIR) Non-Dispersive Infrared
DETECTION METHOD: Diffusion
GASES: R8 model: R134a, R404a, R410a, R507a
R9 model: R11, R22
RANGES: 0/500 ppm
0/3,000 ppm
OUTPUT SIGNAL: Linear 4/20 mA (max input impedance: 700 Ohms)
POWER SUPPLY: +24 VDC, 250 mA
ACCURACY: +/- 5% of value, but dependant on calibration gas accuracy
RESOLUTION: 1% of full-scale
RESPONSE TIME: T50 = less than 30 seconds
T90 = less than 60 seconds
ZERO DRIFT: Less than 1% of full-scale per month, non-cumulative
SPAN DRIFT: Less than 1% of full-scale per month, non- cumulative
LINEARITY: +/- 3% of full-scale
REPEATABILITY: +/- 1% of full-scale
WIRING CONNECTIONS: 3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft.
ENCLOSURE: Injection-molded NEMA 4X polycarbonate
Hinged lid with captive screw. For non-classified areas.
TEMPERATURE RANGE: -50°F to +120°F (-45°C to +49°C)
HUMIDITY RANGE: 5% to 100% condensing
DIMENSIONS: 7.5” high x 6.5” wide x 3.75” deep
WEIGHT: 3 lbs
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
CK-Cup-Hose
(2982)

CALIBRATION TECHNOLOGIES  CK-Cup-Hose

Standard cup, large cup & 3 ft hose



$37.00 
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$61.00 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$199.00 
SHA-024-B
(2987)

CALIBRATION TECHNOLOGIES  SHA-024-B

CTI SHA-24 100dB Horn/Strobe 24 VDC. White body and blue lens. With weather proof mounting backbox. UL1638 approved.

Configure

$233.00 
SHA-120-B
(2988)

CALIBRATION TECHNOLOGIES  SHA-120-B

CTI SHA-120 99dB Horn/Strobe 120 VAC. White body and blue lens. With weather proof mounting backbox. UL Listed. NEMA 4X enclosure.

Configure

$261.00 
SHA-PY-120-B
(7080)

CALIBRATION TECHNOLOGIES  SHA-PY-120-B

CTI SHA-PY-120 Horn and Strobe. Weather-proof. 120 VAC. Two or three wire connection. High intensity 5 Joules Xenon flash and 8 selectable horn tones. Wall or ceiling mount. NEMA 4X. UL listed.

Configure

$340.00 
SL3-_24-R____-B
(6570)

CALIBRATION TECHNOLOGIES  SL3-24-R-B

CTI SL3 LED stack light with 105 dB buzzer. Up to 5 24VDC or 120VAC Flashing light modules (62 fpm). Polycarbonate Housing. 1/2" NPT conduit. IP66. NEMA 4X. UL listed.

Configure

$460.00 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$635.00 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,090.00 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,188.00 
> REFRIGERANTS :    18 Items found.
RD-VRF-R32____-_24
(7186)

MACURCO  RD-VRF-R32-24

Macurco RD-VRF Refrigerant Leak Detector with NDIR Sensor 0-5000 ppm, Alarm levels 1000 ppm & 2000 ppm. Includes 2 SPDT (Form C) Relays, 83 dB Alarm Buzzer and Modbus RTU outputs. Multicolor LED status indicator, life expectancy >8 years. 24V or 120V.

Configure

$553.19 
P-7231
(6787)

PROSENSE  P-7231

Prosense P-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$746.46 
P-9233
(7139)

PROSENSE  P-9233

Prosense P-9233 Gas Detector with Infrared sensor for R4448A with range 0-2000ppm Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$797.94 
PQN-7231-1/2
(6960)

PROSENSE  PQN-7231-1/2

Prosense PQN-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$926.64 
PQD-7231-1/2
(6748)

PROSENSE  PQD-7231-1/2

Prosense PQD-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,081.08 
PQD-9233-1/2
(7138)

PROSENSE  PQD-9233-1/2

Prosense PQD-9233 Gas Detector with Infrared sensor for R4448A 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
AT-2064-A-000-0
(2912)

INTEC  AT-2064-A-000-0

Intec Controls PolyGard AT-2000 V3 Analog Gas Transmitter for Refrigerants (HCFC and HFC) 0-500 / 0-1000 / 0-2000 ppm (infrared). 2 relay outputs, 1 4-20mA & 2-10V analog output. Wall mounted. NEMA 4X Enclosure. UL Listed and CSA Certified. Factory configured for either R123, R125, R410a, R22, R134a, R404a or R407a

Configure

$1,251.00 
GG-VL2-R
(4138)

CALIBRATION TECHNOLOGIES  GG-VL2-R

CTI GG-VL2-R Refrigerant Vent Line for R22, R134a, R404A, R507A and other CFC / HFC / HCFC gases 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless steel enclosure.

Configure

$1,434.00 
VL-F7-R22-N4-LPA-MK
(3717)

HONEYWELL  VL-F7-R22-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for R22 Refrigerant 0 to 1,000 ppm. Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
IR-F9-R22-1000-COM
(6594)

HONEYWELL  IR-F9-R22-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R22 with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R404a-1000-COM
(6590)

HONEYWELL  IR-F9-R404a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R404a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R134a-1000-COM
(1540)

HONEYWELL  IR-F9-R134a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R134a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R422d-1000-COM
(6593)

HONEYWELL  IR-F9-R422d-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R422d with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R407a-0500-COM
(6595)

HONEYWELL  IR-F9-R407a-0500-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R407a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-HFO1234yf-1000-COM
(6596)

HONEYWELL  IR-F9-HFO1234yf-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant HFO1234yf with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,001.73 
IR-F9-R410a-1000-COM
(1545)

HONEYWELL  IR-F9-R410a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R410a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,074.57 
IR-F9-R507a-1000-COM
(6592)

HONEYWELL  IR-F9-R507a-1000-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Refrigerant R507a with 4-20 mA output, 24VDC Power, NEMA-1 or Stainless Steel enclosure.

Configure

$2,074.57 
GG2SAXXX-X-R12
(5014)

ION SCIENCE  GG2SAXXX-X-R12

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Refrigerants (R12, R1301, R134a, R22, R11, R502, R404a, R407c, R410a or R507). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

Cookie Notice