Rc Systems 2100al-0-9024/007p/l0 | Nitrogen Dioxide | Gas Detectors (division 2 Non-incendive) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

RC SYSTEMS   2100AL-0-9024/007P/L0

RC SYSTEMS 2100AL-0-9024/007P/L0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

2100AL-0-9024/007P/L0   
1,789.61

Enclosure Type
Sensor Range
Splash Guard

 3 Weeks  ]
24 Variants of base SKU

The SenSmart 2000 2-Wire 4-20mA Loop Powered Gas Monitor accepts oxygen and many toxic gases by offering a wide variety of electrochemical gas sensors. SenSmart 2000s utilize our popular “GEN 1 smart sensor” proprietary technology to provide sensor recognition and temperature compensation within the SenSmart 2000. Each GEN 1 smart sensor has its’ own non-volatile memory to store records of serial number, born-on date, initial calibration values, engineering units and temperature compensation algorithm.

FEATURES HIGHLIGHT
  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Graphic display shows values,units, trend graph, alarm levels
  • Non-polarized loop powered interface eliminates wiring errors
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Non-intrusive, prompted calibration with programmable cal-gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data and more
  • Fault supervision circuitry detects failed sensor and transmits warning
  • Setup in hazardous area requires only simple magnetic wand

OEM VERSION OF THE GDS CORP GASMAX EC

SPECIFICATIONS
Power Supply10-30VDC at less than 0.75 watts
Display64 x 128 pixel LCD with 30-minute trend, bar graph and engineering units display
Standard OutputStandard 2-wire 4-20mA current sink . Max loop Resistance is 600 ohms with nominal 24VDC power supply
TempElectronics -40°C to +60°C. See Electrochemical Sensor Manual for additional information
HousingAluminum with epoxy paint standard; Optional #316 stainless steel, Optional Ul94 Poly Black Plastic Enclosure
Dimensions(Aluminum) Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
(Poly) Width 5” (127 mm), Height 7” (178 mm), Depth 4” (101 mm) Shipping weight 3 pounds (2 kg)
ApprovalsCSA Certified Div 1 & 2 Groups B, C, D. Suitable for explosion-proof installations
CSA Certified Div 1 & 2 Groups A, B, C, D for Intrinsically safe installations
Warranty5 year limited warranty
For sensor warranty see sensor specifications sheet.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    9 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
CYL-10474525
(4726)

PORTAGAS  CYL-10474525

Calibration Gas Nitrogen Dioxide (NO2) 10 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$252.43 
CYL-10474553
(1507)

PORTAGAS  CYL-10474553

Calibration Gas Nitrogen Dioxide (NO2) 50 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$252.43 
ISC-1810-2219-EQUIV
(2585)

PORTAGAS  ISC-1810-2219-EQUIV

Calibration Gas Nitrogen Dioxide 5ppm Balance Nitrogen 58 Liter GAL C-10 Inlet Cylinder (Made by Portagas) (No RFID tag)

Configure

$315.53 
10-9024-007P
(7099)

RC SYSTEMS  10-9024-007P

RC Systems 10-9024/10-9529 Gen I EC Smart Sensor for Series 1000, 2000, 3000 Gas Detectors with ST-48 transmitter, Nitrogen Dioxide (NO2) up to 200ppm (0-7, 0-10, 0-20, 0-50, 0-100, 0-200)ppm

Configure

$536.36 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Division 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20mA inputs.

Configure

$12,179.52 
> NITROGEN DIOXIDE :    28 Items found.
M001-0011-000
(6004)

MPOWER  M001-0011-000

mPower UNI MP100 Portable Single Gas Detector for detection of Nitrogen Dioxide (NO2) 0-20ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$278.40 
TX1-4
(5967)

INDUSTRIAL SCIENTIFIC  TX1-4

Industrial Scientific Tango TX1 Gas Detector for Nitrogen Dioxide (NO2) 1-150 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

PPS+-NO2
(6814)

PROSENSE  PPS+-NO2

Prosense PPS+-NO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.



$429.00 
PPS-RNO2
(6812)

PROSENSE  PPS-RNO2

Prosense PPS-RNO2 Addressable Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$429.00 
BWS1-D-Y
(6391)

BW  BWS1-D-Y

BW Solo Serviceable Single-gas Detector for Nitrogen dioxide (NO2) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-ND
(2046)

MACURCO  TX-6-ND

Macurco TX-6-ND low voltage Gas Detector, Controller and Transducer for Nitrogen Dioxide (NO2) 0-20 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC. power ETL Listed to UL 61010-1.

Configure

$648.99 
TX-12-ND
(3417)

MACURCO  TX-12-ND

MACURCO TX-12-ND line voltage Gas Detector, controller and transducer for Nitrogen Dioxide (NO2) 0-20ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$656.26 
364-455-01-365-732-01
(6156)

DELPHIAN  364-455-01-365-732-01

Delphian GazTell Fixed Point Electrochemical Gas Detector for Nitrogen Dioxide (NO2) 0-100ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-6824
(6809)

PROSENSE  PC3-6824

Prosense PC3-6824 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-6834
(6784)

PROSENSE  P-6834

Prosense P-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXN1
(1924)

HONEYWELL  SPSTAXN1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Nitrogen dioxide (NO2) 0-10ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved.

Configure

$993.35 
PQN-6834-1/2
(6957)

PROSENSE  PQN-6834-1/2

Prosense PQN-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
GG-NO2-B-10
(5982)

CALIBRATION TECHNOLOGIES  GG-NO2-B-10

CTI GG-NO2-B Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. NEMA 3RX polycarbonate housing. CSA and UL approved.

Configure

$1,122.00 
2106B1422
(1467)

HONEYWELL  2106B1422

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitrogen Dioxide (NO2) 0-10 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
PQD-6834-1/2
(6745)

PROSENSE  PQD-6834-1/2

Prosense PQD-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109024/007P-L0
(6915)

RC SYSTEMS  1100ALD-109024/007P-L0

RC Systems SenSmart 1100 gas detector for Nitrogen Dioxide (NO2) 0-7ppm to 0-200ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive).

Configure

$1,314.28 
GG-NO2-10-EXP
(5980)

CALIBRATION TECHNOLOGIES  GG-NO2-10-EXP

CTI GG-NO2-EXP Explosion Proof Electrochemical Gas Sensor for Nitrogen Dioxide (NO2) 0-10 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
41001AL-0-1024/0005P/L0
(7175)

RC SYSTEMS  41001AL-0-1024/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1024/0005P/L0
(7130)

RC SYSTEMS  51001AL-0-1024/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Nitrogen Dioxide (NO2) 0-5ppm to 0-200ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-640026-010G
(6371)

DETCON  961-640026-010G

Detcon DM-100-NO2 Electrochemical Nitrogen Dioxide (NO2) 0-10ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.