Honeywell Xnxutavnnic1 | Carbon Dioxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   XNXUTAVNNIC1

HONEYWELL XNXUTAVNNIC1
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell XNX Universal Gas Detector Transmitter including MPD AMIC1 IR (infrared) CO2 Carbon Dioxide sensor 0-1%/0-5% Vol. Backlit LCD Display, HARTŪ over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

XNXUTAVNNIC1   
2,276.97

Agency Approval & Entry Threads
Enclosure
Interface option
Local HART Port
Low Temperature
Custom Tag

   10 Weeks  ]



The XNX Universal Transmitter marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs.

FEATURES

High performance
  • Flammable gas detection 0 to 100% LFL/LEL
  • Point IR with heated optics provides immunity to poisoning and no hidden faults
  • Open-path IR flammable gas detection in LEL-m measurement
  • Electrochemical cell offers toxic gas detection in ppm
  • IR cell provides CO2 and combustible gas monitoring
  • Robust and reliable operation in explosive areas and harsh environments
Flexible Operation
  • 3 versions - supports mV (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection
  • Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability
  • 4-20mA with HARTŪ as standard
  • Multiple communications options include up to 3 relays, MODBUSŪ and FOUNDATIONŪ H1 Fieldbus (pending)
  • Optional local IS port for handheld HART configurator
Easy to Use
  • Large, backlit, easy-to-view LCD display offers multisensory indicators (visual icons, colored buttons, text, etc.) to display gas and sensor readings
  • User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese)
  • Self-test and fault indication features
  • Non-intrusive, one-man operation
  • Quick calibration with auto-inhibit
Easy to Install
  • 3 or 4 wire operation, source, sink or isolated
  • Use with conduit or cable installations
  • Simple plug-in sensors and replaceable cells
  • NEMA 4X IP66 rated for rugged indoor/outdoor use
Cost Effective
  • Minimal training required
  • One-man operation
  • Plug-in sensor replacement
  • All necessary accessories included
Applications
  • Offshore Oil & Gas production platforms
  • Onshore Oil terminals
  • Refineries
  • Gas Transmission
  • Gas Distribution
  • LNG terminals
  • Gas storage terminals
  • Chemical plants
  • Petrochemical plants
  • Solvent recovery operations

XNX is designed for flexible integration, simple installation, user friendly operation and straightforward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. Users are assured of being protected in all conditions with Honeywell Analytics gas monitoring solutions.

Bringing together the best solutions in gas detection

Catalytic Bead
  • Supports Honeywell Analytics 705, 705HT, Sensepoint, Sensepoint HT and MPD sensors
  • Fast response to wide range of hydrocarbons and flammables
Honeywell XNX Catalytic Bead sensor options

XNX's modular design enables Honeywell Analytics to offer appropriate, cost effective solutions to a wide range of gas detection requirements.

With the XNX, you are freed from the need to add extra controllers, junction boxes, relays, monitors and other equipment accessories.

The XNX Universal Transmitter is an excellent choice for those who want a total integrated monitoring and safety solution for an industrial plant.

The XNX's powerful advanced communications module adds increased functionality and flexibility to a gas detection network. Standard HART communications, along with optional Modbus, Foundation Fieldbus (pending) or relays, interface with a PLC and a host of other protocol compatible devices found in industrial applications.

XNX Output Options

Back-lit, easy-to-read LCD display with icons includes a broad range of language options including English, Spanish, French, Italian, Portuguese, German, Russian and Chinese to meet global requirements.

Ordering Information

The XNX part numbering system contains all necessary information to convey the product configuration including options. Agency, Port Thread, Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or Fieldbus interfaces and factory installed local HARTŪ. To order XNX parts, call 800-538-0363.

XNX Order Information Matrix

XNX Transmitter
Material LM25 Aluminum, painted (SS316 painted optional)
Cable Entries 5 conduits/cable entries – (2 right, 2 left, 1 bottom) Available in ū" NPT, or M25
Termination Cage Clamp pluggable Terminal Blocks with retaining screws, 0.5 to 2.5mm (12-28 AWG)
Mounting XNX Enclosure Bracket (ears on casting for u-bolt). Integral cast mounting flanges provide secure mounting to surfaces, channels or up to 6" Pipe.
Optional Remote sensor (up to 50 ft / 15.2 M) for Cat Bead and Toxic
User interface Standard Custom Backlit LCD. 2.5" High Resolution DOT Matrix Display. Discrete Alarm and Status indication. Reliable Non-Intrusive 4 button interface magnetic wand access. Optional HART Handheld with IS Port
Signal Standard HART over 3-wire 4-20mA (sink or source). Optional Modbus over RS-485 and Foundation Fieldbus
Environmental
Temperature -40°C to +65°C / -40°F to +149°F (sensor dependent)
Humidity 20 to 90% RH non-condensing
IP Rating NEMA 4X IP65
Options
  Form C and SPDT 3 Relays, 240 VAC, 5A (2 Alarm, 1 Fault) (Mutually exclusive with Modbus and Fieldbus Options)
Power
  18V to 32V (24V nominal)
Hazardous Area Approvals
 
Performance Approvals UL Certified Class 1, Div 1
ATEX Zone 1
Display Module & User Interface (Standard)
Display Type Backlit LCD
Information Displayed
Base Information: Gas Reading
Gas Name and Units of measurement
Fault and Alarm Status
Large Numeric concentration or LEL display
Bar graph showing current reading, set points and full scale.
Fault/Alarm and Operating Status Indication: Security settings allow multi level operator access for set-up, configuration and calibration
Event history stores Time and Date of all Alarm, Diagnostic, Configuration events
Interface Magnetic wand with terminal screwdriver (supplied each unit)
4-20mA & HART (Standard Supply)
Description Fully configurable isolated 4-20mA & HART output module providing current sink, current source and isolated modes of operation. (supports HART 6.0 protocol)
Non-intrusive Interface Optional local IS port to enable HOT connection of a HART handheld configurator
Operating Modes Current sink / Current source / Isolated current sink /Conventional or with HART data
Output Range 0 to 22mA
4-20mA Signal Accuracy +/- 1% FS
Max loop resistance 600 Ohms at 24Vdc loop supply
Functions Supported via HART
Gas Reading Detailed Sensor Information Including: RTC (Excel Only)
Gas Name and Units of measurement 4-20mA signal level Optical Signal Level Calibration and Configuration status
General/Device Information Dynamic Reserve (Excel Only) Detailed Fault and Warning Information
Installation Raw reading Fault and Alarm History
Configuration Temperature
Forcing of 4-20mA output
Local IS HART Port (Optional)
Description Provides externally accessible IS connections to the XNX transmitter to enable HOT connection of HC275/375 HART or equivalent hand held configurator.
Installation Fitted to one of the cable entries on the XNX transmitter.
Environmental Protection Terminals protected by cover to IP 66 when not in use
Relay Module (Optional)
Description Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault relays. Single Pole Double Throw SPDT. Option PCB Factory installed in display module.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Rating
Maximum: 240VAC, 5A (non inductive load) Minimum: 5V, 10mA (non inductive load)
Electrical Connections Fault: Common, Normally Open, Normally Closed
Alarm 1: Common, Normally Open, Normally Closed
Alarm 2: Common, Normally Open, Normally Closed
Configuration
Default Configurable Options
Fault Relay: Fault Relay:
Normally energized Normally energized / normally de-energized
Non latching None
Signal inhibit as fault Enable/disable
Alarm 1 / 2 Relays: A1 / A2 Relays:
Normally de-energized Normally energized / de-energized
Non latching Latching / non latching
Alarm rising on gas reading Alarm on rising / falling
Alarm level 20% and 40% of scale Alarm level 10% to 90% of full scale
Hysteresis of 2% of scale
Re-setting of Latched Relays Easily accessible interface on display (if used) or via HART interface (local or remote)
Note Use of the Relay Module or 'Other' Communications Module (E.g. Foundation Fieldbus) is mutually exclusive. However, relay function may be used in conjunction with standard communication output i.e. 4-20mA with HART.
Relay Specific Functions via HART Interface Relay status information / Reset of latched conditions / Configuration of relays Forcing of relay state
Reset through non intrusive User Interface. Remote Switch closure using Remote Reset input Remotely through HART
Foundation Fieldbus Module (Optional)
Description Foundation Fieldbus compliant digital communications interface enables connection of the XNX transmitter to a multi-drop Foundation Fieldbus H1 network.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections Sig+, Sig- and Screen
Physical Layer Conforms to IEC 1158-2 and ISA 50.02, 31.25Kbits/s
Maximum No. of Nodes 32
Functions Supported
Gas Reading Detailed Sensor Information Including: Detailed Fault and Warning Information:
Gas Name and Units of measurement Optical Signal Level Fault and Alarm History
Instrument status (OK, warning, fault, over-range) Dynamic Reserve (Excel Only) Zero Calibration
Remote zero and span calibration (detector dependent) 24V supply voltage
Remote zero and span calibration (detector dependent) Temperature
  RTC (Excel Only)
  Calibration and Configuration status
Modbus RTU Module (Optional)
Description The Modbus output module provides an Isolated RS485 output to enable the connection of the XNX transmitter to a multi-drop Modbus network
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections RS485+, RS485-, Drain
Physical Layer Isolated RS485, 1200 to 19.2K Baud
Maximum No. of Nodes 254 XNX compatible transmitters only
Protocol Modbus RTU
Functions Supported As per Foundation Fieldbus Module (Optional) - see above
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
0060-1051
(1883)

HONEYWELL  0060-1051

Ferrite bead for XNX transmitters with mV sensors



$17.28 
1226A0411
(834)

HONEYWELL  1226A0411

Calibration Gas Flow Adaptor (cup) for use with XNX MPD Catalytic Bead and IR/CO2 sensors.



$105.75 
02000-A-1635
(1881)

HONEYWELL  02000-A-1635

Honeywell Weatherproof cap for use with Toxic/Oxygen detector including remote gassing nozzle (for Toxic Sensepoint Zareba and Sieger, Signalpoint, Satellite -with adapter-, XNX MPD, Series 2000 and 705 sensors)



$110.94 
CYL-90302169
(1273)

PORTAGAS  CYL-90302169

Calibration Gas Carbon Dioxide (CO2) 1000 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10046000
(876)

PORTAGAS  CYL-10046000

Calibration Gas Carbon Dioxide (CO2) 25,000 ppm 2.5% Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90092236
(875)

PORTAGAS  CYL-90092236

Calibration Gas Carbon Dioxide (CO2) 10,000 ppm 1% Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
02000-A-1640
(1471)

HONEYWELL  02000-A-1640

Honeywell Nylon Weather Protection for Combustible/MPD, Sieger, Zareba Sensepoint, XCD, RTD, RFD, 705, XNX Combustible Sensors with test/calibration gas port.



$133.75 
2441-0022
(1969)

HONEYWELL  2441-0022

Honeywell UL/CSA Aluminum 6 wire Junction Box 3/4" NPT entries, can be used for remote sensors with 3/4" NPT male threads, can be used with MPD sensors.



$362.88 
1226-0301
(1891)

HONEYWELL  1226-0301

Replacement IR Cartridge Carbon dioxide (CO2) 0-5%VV for Honeywell XNX



$754.79 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8mA outputs. IP65. UL and CSA approvals (Class I Div 2).

> CARBON DIOXIDE :    27 Items found.
I-M308WV
(2955)

INTEC  I-M308WV

Intec Controls I-M308 Infrared (NDIR) Gas Transmitter for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-(5)10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm) and 24 VAC/VDC powered.

Configure

$166.68 
I-M350WV-R000
(2956)

INTEC  I-M350WV-R000

Intec Controls I-M350 Infrared (NDIR) Gas Transmitter and Control System for Carbon Dioxide (CO2) 0-2000 or 0-5000 ppm. Voltage (0-10 V) or current (4-20 mA) output signal. Wall or Duct mounted. Tri-color LED (normal/warning/alarm). Optional relay/ouput control, audible alarm, LCD Display and relative humidity measurement.

Configure

$191.88 
SAN-10
(7050)

CO2METER  SAN-10

CO2Meter SAN-10 Personal Safety Monitor for Carbon Dioxide (CO2) 0-5% with NDIR sensor. Visual strobe light, audible and vibrating alarmas. Includes rechargeable Li-Ion battery, 110/240 VAC USB Wall Adapter and LCD Display. IP54 rubber enclosure.



$383.04 
CD-6MC
(4482)

MACURCO  CD-6MC

MACURCO CD-6 low voltage Carbon Dioxide (CO2) 0-5000ppm Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$495.09 
CD-6G
(6828)

MACURCO  CD-6G

MACURCO CD-6G / CD-6B Greenhouse Carbon Dioxide (CO2) 0-5% vol Gas Detector, controller and transducer. Selectable 4-20mA output, buzzer, alarm and fan relays and digital display options. 12 to 24 VAC or 12 to 32 VDC power. Auto or Manual Calibration (Relays, 4-20mA output). ETL Listed to UL 61010-1.

Configure

$495.09 
CD-12MC
(4494)

MACURCO  CD-12MC

MACURCO CD-12 line voltage Gas Detector, controller and transducer for Carbon Dioxide (CO2) 0-5000ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$515.08 
RAD-0102-6
(7048)

CO2METER  RAD-0102-6

CO2Meter RAD-0102-6 Remote "CO2 Storage Safety 3" gas leak detector with local and remote displays for Carbon Dioxide (CO2) 0-5% (0-50,000 ppm) with NDIR sensor. Includes audible and visual alarms, 3 alarm relays, 4-20 mA output and LCD display. IP54 Enclosure. UL Listed, meets NFPA, IFC, and NBIC requirements, OSHA and NIOSH TWA standards. Alarms 5,000 TWA, 1.5% (user configurable), 3% (user configurable), sensor life > 15 years, 12-24VDC power, includes 110-220VAC multi-region power adapter.

Configure

$672.00 
364-510-01
(6148)

DELPHIAN  364-510-01

Delphian GazTell Fixed Point Infrared Gas Detector for Carbon Dioxide (CO2) 0.02% to 4.5% vol. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

P-7133
(6786)

PROSENSE  P-7133

Prosense P-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with range 0-5000ppm or 0-5% vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$823.68 
PQN-7133-1/2
(6959)

PROSENSE  PQN-7133-1/2

Prosense PQN-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with ranges 0-5000ppm or 0-5%vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,003.86 
PQD-7133-1/2
(6747)

PROSENSE  PQD-7133-1/2

Prosense PQD-7133 Gas Detector with Infrared sensor for Carbon Dioxide (CO2) with ranges 0-5000ppm or 0-5%vol. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
1400ALD-101032/015P-L0
(6906)

RC SYSTEMS  1400ALD-101032/015P-L0

RC Systems SenSmart 1400 gas detector for Carbon Dioxide (C02) 0-1.5% or 0-5% with 'ST-48' smart transmitter. IR sensor. 3-Wire bridge. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,432.47 
100-0008-SS/100-0015-CO2
(4752)

ESP SAFETY  100-0008-SS/100-0015-CO2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Carbon Dioxide (CO2) 0-2% vol, 0-5% vol or 0-3000ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
GG-CO2-1
(2964)

CALIBRATION TECHNOLOGIES  GG-CO2-1

CTI GasGuard CO2 Carbon Dioxide Infrared Sensor (0-1%, 0-3% and 0-5%) for gas leak detection in wineries, food processing areas, bottling plants and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,519.00 
CM-900
(7201)

CO2METER  CM-900

CO2Meter CM-900 Industrial Gas Detector with NDIR (Infrared) sensor for Carbon Dioxide (CO2) 0-50,000ppm for Harsh Environments. Includes 3 configurable alarms, 3 dry contact relays, 4-20mA output and backup battery. 9-32VDC. Aluminum enclosure. IP64.

Configure

$1,535.04 
SPXCDULNB1
(661)

HONEYWELL  SPXCDULNB1

Honeywell XCD Sensepoint Gas Detector, Carbon Dioxide (CO2) Infrared Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for carbon dioxide (CO2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 2%Vol. only UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,731.84 
54001AL-0-9053/005P/L0
(7119)

RC SYSTEMS  54001AL-0-9053/005P/L0

RC Systems SenSmart 5400 3-wire gas detector for Carbon Dioxide (CO2) 0-1.5% or 0-5% with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,809.09 
IR-F9-CO2-1-COM
(1547)

HONEYWELL  IR-F9-CO2-1-COM

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Carbon Dioxide (CO2) with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

Configure

$2,001.73 
967-425520-100
(6068)

DETCON  967-425520-100

Detcon IR-700-CO2 Infrared (NDIR) non-intrusive Smart Sensor for Carbon Dioxide (CO2) 10-100%. Includes LED display, 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

34001AL-0-9053/005P/L0
(6897)

RC SYSTEMS  34001AL-0-9053/005P/L0

RC Systems SenSmart 3400 3 wire gas detector for Carbon Dioxide (CO2) 0-1.5% or 0-5% with 'ST-48' smart transmitter with infrared (IR) sensor. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
Page: 1 | 2 | All
Cookie Notice