NOTIFIER by Honeywell NBG-12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel.

NBG-12LX   
Please Email us your request for quote   

Labeling
Backbox

   2 Days  ]
2 Variants of base SKU
The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm.

Features

  • Maintenance personnel can open station for inspection and address setting without causing an alarm condition.
  • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm.
  • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated.
  • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire).
  • Can be surface mounted (with SB-10 or SB-I/O) or semiflush mounted. Semi-flush mount to a standard singlegang, double-gang, or 4" (10.16 cm) square electrical box.
  • Smooth dual-action design.
  • Meets ADAAG controls and operating mechanisms guidelines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force.
  • Highly visible.
  • Attractive shape and textured finish.
  • Key reset.
  • Includes Braille text on station handle.
  • Optional trim ring (BG12TR).
  • Meets UL 38, Standard for Manually Actuated Signaling Boxes.
  • Up to 99 NBG-12LX stations per loop on CLIP protocol loops.
  • Up to 159 NBG-12LX stations per loop on FlashScan® protocol loops.
  • Dual-color LED blinks green to indicate normal on FlashScan® systems.

Construction
Shell, door, and handle are molded of durable polycarbonate material with a textured finish.

Installation
The NBG-12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes).

Operation
Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTIVATED” (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 159 on FlashScan® systems, 1 – 99 on CLIP systems).

Architectural/Engineering Specifications
Manual Fire Alarm Stations shall be non-coded, with a keyoperated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm.

Product Line Information

NBG-12LX: Dual-action addressable pull station. Includes key locking feature.

SB-10: Surface backbox; metal.

SB-I/O: Surface backbox; plastic.

BG12TR: Optional trim ring.

17021: Keys, set of two.

NY-Plate: New York City trim plate

NBG-12LX SPECIFICATIONS
Shipping Weight: 9.6 oz. (272.15 g)
Normal Operating Voltage: 24 VDC
Maximum SLC loop voltage: 28.0 VDC
Maximul SLC loop current: 375 uA
Temperature Range: 32°F to 120°F (0°C to 49°C)
Relative Humidity: 10%-93% noncondensing.
Use: Indoors in a dry location
Agency Approvals:

In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status

UL / CUL Listed: S692 (listed for Canadian and non-Canadian applications)

MEA: 67-02-E

CSFM: 7150-0028:0199

FDNY: COA #6038 (NFS2-640), COA #6058 (NFS2-3030)

BSMI: CI313066760047

U.S. Coast Guard: 161.002/23/3 (AFP-200); 161.002/27/3 (AM-2020/AFP-1010; 161.002/42/1 (NFS-640)

Lloyd’s Register: 02/6007 (NFS-640); 94/60004 (E2) (AFP-200); 03/60011 (E1); 07/60007 (NFS2-3030)

FM Approved

Patented: Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108.
Export Info
Made inMexico

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
SB-10
(6935)

NOTIFIER  SB-10

Notifier SB-10 (Metal) or SB-I/O (Plastic) Surface Backbox for Notifier NBG-10 or NBG-12 pull stations.

NBG-12LR
(5811)

NOTIFIER  NBG-12LR

Notifier NBG-12LR Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual-action agent release station. FM Approved and cUL Listed.

NBG-12LOB
(4603)

NOTIFIER  NBG-12LOB

Notifier NBG-12LOB Pull Station which provides a Fire Alarm Control Panel (FACP) with a single alarm input signal. Includes dual action operation, Key-Lock Reset function, outdoor-use gasket and sealed switch. UL Listed.



 
NBG-12LRA
(4142)

NOTIFIER  NBG-12LRA

Notifier NBG-12LRA Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual action operation. Abort switch. Power-on and released indication. FM Approved and cUL Listed.

XAL-53
(6225)

NOTIFIER  XAL-53

Notifier XAL-53 Explosion Proof / Weather Proof Pull Station with Ring. Copper Free Aluminum Enclosure and 3/4" NPT conduits. Suitable for Class I Div 1, Class II Div 1 & 2 and Class III on Hazardous Locations. NEMA 7. UL and CSA Approvals.



 
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> CALL POINTS :    43 Items found.
NBG-12
(6824)

NOTIFIER  NBG-12

NOTIFIER by Honeywell NBG-12 Non-Coded Conventional Manual Fire Alarm Pull Station that initiates an input signal for any conventional control panel (FACP). Single or Dual Action Versions. UL, CSFM and FM Approvals.

4099-9004
(6848)

TYCO  4099-9004

Tyco Simplex 4099-9004 addressable manual station with communication module for IDNet or MAPNET II. LED indicator. Breakglass or push operation. Surface or Flush mounting. NEMA 1. Complies with ADA requirements. UL listed.

Configure

$67.52 
BG3W1NNN_BR
(1587)

MEDC  BG3W1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. Weatherproof. IP66 and IP67.

Configure

$193.80 
IS-CP4A-BG-ST-NF-NL-RD
(4080)

E2S  IS-CP4A-BG-ST-NF-NL-RD

E2S IS-CP4A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PT-ST-NL-RD
(4082)

E2S  IS-CP4A-PT-ST-NL-RD

E2S IS-CP4A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PB-ST-NL-RD
(4081)

E2S  IS-CP4A-PB-ST-NL-RD

E2S IS-CP4A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BExCP3B-BG-ST-NF-NL-RD-06
(5136)

E2S  BExCP3B-BG-ST-NF-NL-RD-06

E2S BExCP3B-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-BG-ST-NF-NL-RD
(4083)

E2S  BExCP3A-BG-ST-NF-NL-RD

E2S BExCP3A-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BG2WNN1_NR
(1586)

MEDC  BG2WNN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. Weatherproof. IP66 and IP67.

Configure

$324.48 
BG3I1NNN_BR
(4152)

MEDC  BG3I1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. ATEX approved Ex II 1G. IP66 and IP67.

Configure

$328.96 
GNEXCP6A-BG-SNNNRD
(4086)

E2S  GNEXCP6A-BG-SNNNRD

E2S GNExCP6A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-BG-SNSNNRD06
(6443)

E2S  GNEXCP6B-BG-SNSNNRD06

E2S GNExCP6B-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

BG2EDC1_NR
(4150)

MEDC  BG2EDC1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. DC or AC Version. EExed IIC T6 (T4 if resistors or diode fitted) ATEX Approved Ex II 2G. IP66 and IP67.

Configure

$360.46 
BG2INN1_NR
(4151)

MEDC  BG2INN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. EExia IIC T4, ATEX Approved Ex II 1G. IP66 and IP67.

Configure

$378.49 
BExCP3A-PT-ST-NL-RD
(4085)

E2S  BExCP3A-PT-ST-NL-RD

E2S BExCP3A-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-PB-ST-NL-RD
(4084)

E2S  BExCP3A-PB-ST-NL-RD

E2S BExCP3A-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-PB-ST-NL-06
(5137)

E2S  BExCP3B-PB-ST-NL-06

E2S BExCP3B-PB Push Button Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-PT-ST-NL-RD-06
(5138)

E2S  BExCP3B-PT-ST-NL-RD-06

E2S BExCP3B-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BGWNNNNN100DSNNN7R
(4159)

MEDC  BGWNNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Weatherproof and dust proof only (Uncertified). IP66 & IP67. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$477.46 
BGIBNNNN100DSNNN7R
(4157)

MEDC  BGIBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exia (Intrinsically Safe). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD. GOST R, CQST and Inmetro approvals also available.

Configure

$494.64 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.