GAS DETECTORS > LEL AND TOXIC
GASMAX II 3-Wire Gas Monitor with local stainless steel sensor head configured for Catalytic Bead sensor with range 0-100% LEL, 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with local stainless steel sensor head configured for Sulfur Dioxide (SO2) with range 0-20/0-100 ppm (included).
The GASMAX II Gas Monitor with Catalytic Bead sensor offers a cost effective and proven solution for the detection of a wide range of combustible gases. Available in both single and dual channel models, the
GASMAX II is CSA certified for use in Class 1 Div 1 & Div 2 explosion proof installations.
The highly visible backlit display shows calibrated engineering values, bargraph data, 30-minute trend and setup information. An internal real-time clock time-stamps calibration and alarm events for later review. Front panel LEDs continuously indicate alarm status.
In addition to combustible gas, the dual-channel-capable GASMAX II can be configured to host an additional electrochemical sensor for simultaneous monitoring of combustible and toxic or oxygen levels. Sensors can
be mounted locally or in a remote sensor head (toxic sensors must be located within 25 feet).
In addition to dual 4-20mA current loop outputs, an RS-485 two-wire MODBUS® interface and three optional 5A relays are available to communicate with controllers or local alarm indicators.
Operator interface is via a menu-driven magnetic keypad, allowing
complete setup and calibration without hazardous area declassification.
Smart Sensor technology allows a memory chip in each Smart Sensor to
provide the GASMAX II with information on sensor type, range, units, born-on date and previous calibration data.
Available Ranges
Options:
- EC channel: Accepts signals from GDS Corp toxic / O2 sensors (included)
- Stainless Steel Enclosure
- ATEX Certified (not available with Aluminum sensor head)
- Wireless 900 MHz
- CSA Certified for explosion proof installations.
- Monitor both Toxic / O2 and LEL / VOC from single point.
- Standard dual 3-wire 4-20mA current source (optional output 3-wire with EC sensor).
- Non-intrusive one-person prompted calibration.
- Smart Sensors store calibration & alarm events.
- Real time clock tags alarm events.
- Aluminum sensor head available for reactive gases.
- Backlit display for better visibility in low light.
Sensor Head Options
- Local Stainless Steel - XP & IS
- Local Stainless Steel (with splash guard) - XP & IS
- Local Aluminum - IS ONLY
- Local Aluminum (with splash guard) - IS ONLY
- Remote Stainless Steel - XP & IS
- Remote Stainless Steel (with splash guard) - XP & IS
- Remote Aluminum - IS ONLY
- Remote Aluminum (w/ splash guard) - IS ONLY
Notes:
- Remote sensor installations do not utilize Smart Sensor interface
- Maximum distance for remote e-chem sensor connection is 25ft (3m).
- Maximun distance for remote LEL sensor connection is 300 ft.
- Highly reactive gases REQUIRE aluminum sensor head and IS in
hazardous area.
Operation and Maintenance Manual of the GasMax Detectors
Quick Start Guides for the GasMax-II:
Quick Start
VOC/PID
SmartIR
GDS-IR
Catalytic Bead