GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Industrial Process Hydrocarbons (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Propylene (C3H6), Acetylene (C2H2), Methane (CH4), Ethylene (C2H4), Isopropyl Alcohol (C3H8O), Acetone (C3H6O), p-Xylene (C8H10), MEK (C4H8O) adn Styrene (C8H8).

GDS-IR-1-118-0   
Please Email us your request for quote   

Sensor Head
Sensor Type
Options
Rain Shield
Enclosure
Tag

 2 Weeks  ]
108 Variants of base SKU / 30 Shown

The GDS-IR Infrared Gas Sensor uses proven, reliable infrared sensing technology to detect dangerous levels of carbon dioxide or explosive levels of methane, propane and other hydrocarbons. The GDS-IR sensor is CSA certified for use in Class 1 Division 1 explosive environ- ments and is CSA performance tested.

Advanced Infrared Technology

The GDS-IR infrared combustible gas sensor offers low total cost of ownership and a seventeen-year MTBF rating. Designed for especially harsh environments, the GDS-IR is virtually maintenance-free and immune to poisoning or etching by any known gas. The sensor element features a self-compensating optical bench, heated optical chamber and fault indication for all failure modes. The optical path can be easily opened for cleaning.

No periodic span calibrations are required. On initial setup and after each cleaning, a simple ‘auto zero’ procedure is used to establish proper operating conditions.

Flexibility

The GDS-IR can be calibrated to read a wide range of combustible hydrocarbons, including methane, propane, hexane, pentane, ethanol, Jet-A, isobutane, propylene and isoproply alcohol, as well as carbon dioxide to 5% by volume. GDS-IR sensors are factory programmed and calibrated when shipped and can be field programmed for alternate response curves. Both LEL and % by volume ranges are available.

GASMAX + GDS-IR Combo

When combined with the GASMAX II monitor, the duo provides local display, 4-20mA output with diagnostics, optional second electrochemical sensor, isolated 4-20mA outputs or MODBUS slave interface with programmable relays.

Reliable Detection

The GDS-IR is manufactured in the USA and includes a five year operational warranty. Applications include refineries, onshore and offshore drilling platforms, fuel loading docks, biogas processing, breweries, wastewater treatment facilities and natural gas storage and distribution.

Calibration Port

It comes with a barb fitting on the end of the GDS-IR, just remove the cap and connect the Tygon calibration tubing.

FEATURES

  • Suitable for use in SIL-2 rated safety systems
  • High speed response for critical applications (T50 less than 3 sec)
  • 5 Year Warranty and long life lowers total cost of ownership
  • 12 Year Warranty on infrared radiation source
  • Rugged stainless steel construction with no moving parts
  • Heated optical chamber maintains accuracy in cold conditions
  • Operates in constant hydrocarbon and anaerobic atmosphers
  • Ten discrete fault indication values for all failure states
  • Straight line optical path eliminates need for mirrors
  • Managed power-up delay reduces initial load on power supply
  • Industry standard 4-20mA current loop calibrated output
  • Multiple gas calibration curves for %LEL and % by volume
  • CSA Certified C22.2 No. 152-M1984 Performance Tested
  • Manufactured in USA

GDS IR SPECIFICATIONS
Power Input: 18-30VDC at 5 watts (typical). Delayed IR source turn-on minimizes inrush power for distributed systems.
Max Current Average: 210 mA, peak 400 mA at 24VDC
Display None.
Sensor Technology Reliable infrared sensing technology with patented self-compensating optics and easy-to-clean
Standard Output Standard 3-wire 4-20mA current source. Max loop R is 1000 ohms with nominal 24VDC power supply
Output Alarm Conditions Discrete 4-20mA output levels indicate general fault, reference & optics fault, warm-up, zero drift fault, calibration fault, zero and span set and overrange conditions.
Accuracy ± 3% LEL, 0-50% LEL
± 5% LEL, 51 - 100% LEL
Response Time T50 < 3 seconds; T90 < 5 seconds
Temp -40°C to +70°C at 0 to 99% RH
Housing #316 Stainless Steel
Dimensions with j-box Width 5.4” (137 mm), Height with junction box 12.75” (324 mm), Depth 3.5” (89 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D
C22.2 No.152-M1984 (R1997) for performance
Warranty 5 years from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

20-0100
(1739)

GDS  20-0100

GDS Remote XP junction box for GDS-IR with zero-set pushbutton



 
1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-0271
(561)

GDS  10-0271

Sample flow cell assembly for GDS-IR



 
(1740)

GDS  12-0251

Programming adapter for GDS-IR



 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.