Gds Gds-49-1-11-06 | Carbon Monoxide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GDS-49-1-11-06

GDS GDS-49-1-11-06
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GDS-49 Remote Gas Detector Transmitter with Stainless steel sensor head configured for Carbon Monoxide (CO) with range 0-100 to 0-9999 ppm, Explosion Proof (XP). 2-Wire 4-20 mA transmitter.

Inquiry

The GDS-49 (Model 10-0248) two-wire toxic sensor transmitter provides a scaled 4-20mA current sink output suitable for long distance transmission to an appropriate receiver device such as a C1 or C2 Protector series controller or GASMAX transmitter.

Wide Variety of Available Sensors

The GDS-49 is compatible with all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more. Built-in fault detection circuity constantly monitors the sensor for correct operation and sensors can easily be replaced in the field.

Rugged Detection

The GDS-49 is enclosed in a stainless steel housing with integrated flame arrestor and is CSA approved for all Class I, Division 1 and 2 hazardous environments. For certain highly reactive gases that are not compatible with stainless steel, the GDS-49 is also available in a configuration without a flame arrestor that can be installed as intrinsically safe (IS) with an approved IS barrier, A standard junction box is supplied with the GDS-49 for connection to field wiring.

Calibration Required

Initial factory adjustment is completed by installing a fixed gain resistor on the sensor. This resistor establishes the range and provides basic calibration. Since the GDS-49 electronics are completely sealed and potted for maximum protection, final calibration must be performed at the receiver device in order to meet the rated accuracy specifications and accomodate changes in sensor characteristics over time. GDS Corp. offers single, dual, four, eight and sixteen + channel controllers with compatible analog inputs suitable for final calibration, alarm, display and retransmission of monitored gas values.

Easy Installation

The GDS-49 includes an XP junction box and functions with loop voltages ranging from 10-30VDC; voltage drop across the GDS-49 is less than 9 volts. An integral “transient voltage suppressor” protects the GDS-49 against lightning and other electrical transients. Non-polarized wiring elimnates wiring errors.

FEATURES

  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Compatible with all GDS Corp toxic sensors
  • Non-polarized loop powered interface eliminates wiring errors
  • Range and target gas configured by sensor module
  • Fault supervision circuitry detects failed or missing sensor & transmits warning (2mA)
  • Stainless steel case & potted electronics for high noise immunity in electrically noisy environments
  • Industry standard 4-20mA output signal for cable runs > 1000 ft
  • Available without flame arrestor for highly reactive gases
  • Easy interface to all GDS Corp 2, 4, 8 or 16+ channel controllers
  • Combine with GDS-55 Loop-Powered Alarm or GDS-54 Loop-Powered Indicator for more flexibility
  • Manufactured in USA

GDS-49 (Model 10-0248 & 10-0248IS) SPECIFICATIONS
Power Input: 10 - 30VDC 4 - 20mA current loop with less than 9V drop across GDS-49; Maximum 32mA draw with overrange sensors
Display None
Input Accepts microamp-level signals from local GDS Corp toxic or oxygen deficiency sensors
Calibration Range Rough calibration set by sensor; final calibration must be performed by remote receiver device
Accuracy +/- 5% of full scale range (typical)
Standard Output Standard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp --25°C to +60°C (see sensor limitations)
Housing GDS-49 Stainless steel with or without flame arrestor
Dimensions Width 5.3” x Height 9.3” x Depth 2.75” with splash guard
Shipping weight 6.5 pounds (3 kg)
Approvals Model 10-0248 CSA Certified for Div. 1 & 2 Groups B, C, D Exia. Suitable for Explosion Proof and Intrinsically Safe installations.
Model 10-0248IS CSA Certified for Div. 1 & 2 Groups A, B, C, D. Suitable for Intrinsically Safe only.
IMPORTANT: Intrinsically Safe installations require IS barrier 10-0263 (MTL 7787P+) or equivalent./td>
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    9 Items found.
FC-11
(1563)

AUTOMATION DIRECT  FC-11

Signal conditioner and isolator with loop-powered 4-20 mA input and output signal; output can be field calibrated with offset and span adjustments. Slim-line plastic housing with integral 35mm DIN rail mounting adapter and removable screw terminals, 24VDC supply voltage. UL 508 listed, UL listed for Class I, Division 2, Groups A, B, C, D hazardous locations.



$174.00 
1200-0462
(3164)

GDS  1200-0462

GDS Gas Detector Calibration Gas Cylinder Carbon Monoxide (CO) 100ppm. Balance Air. 103DS Stainless Steel Cylinder.

1200-0542
(3163)

GDS  1200-0542

GDS Gas Detector Calibration Gas Cylinder Carbon Monoxide (CO) 300ppm. Balance Air. 103DS Stainless Steel Cylinder.

(261)

GDS  10-0263

GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent



 
10-9011-R06
(2054)

GDS  10-9011-R06

Electrochemical Sensor for GDS-49 remote transmitter configured for Carbon Monoxide (CO) with range 0-100/0-9999 ppm.

10-9511-R06
(295)

GDS  10-9511-R06

Electrochemical Smart Sensor configured for Carbon Monoxide (CO) with range 0-100/0-9999 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-49, GDS-58XP.

1200-0505
(3094)

GDS  1200-0505

GDS Gas Detector Calibration Gas Kit Carbon Monoxide (CO) 300 ppm. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0459
(3092)

GDS  1200-0459

GDS Gas Detector Calibration Gas Kit Carbon Monoxide (CO) 100 ppm. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> CARBON MONOXIDE :    37 Items found.
CM-E1
(638)

MACURCO  CM-E1

Macurco CM-E1 Carbon Monoxide gas detector for residential and commercial office environment. Flush or surface mount options, alarm and trouble relays, and 85 dB buzzer. 9-32 VDC input. NFPA 720-2009 and UL 2075 listed. CSFM Approved.



$66.15 
M015-0001-000
(6333)

MPOWER  M015-0001-000

mPower UNI 321 Disposable Single Gas Detector for detection of Carbon Monoxide (CO) 1-500ppm. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$108.80 
BWC2-M
(4265)

BW  BWC2-M

BW Clip portable gas detector 2 year maintenance free for Carbon Monoxide CO. Low alarm set between 25ppm and 50 ppm, High alarm set between 50ppm and 200 ppm. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

M001-0023-000
(5994)

MPOWER  M001-0023-000

mPower UNI MP100 Portable Single Gas Detector for detection of Carbon Monoxide (CO) 0-500ppm to 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$134.40 
PPS+-CO
(6813)

PROSENSE  PPS+-CO

Prosense PPS+-CO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm, 0-500ppm or 0-1000ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.

Configure

$214.50 
PPS-RCO
(6811)

PROSENSE  PPS-RCO

Prosense PPS-RCO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$214.50 
TX1-1
(5965)

INDUSTRIAL SCIENTIFIC  TX1-1

Industrial Scientific Tango TX1 Gas Detector for Carbon Monoxide (CO) 1-1000 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

BWC2R-M
(5149)

BW  BWC2R-M

BW Clip Real Time portable gas detector with 2 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWC3R-M
(5153)

BW  BWC3R-M

BW Clip Real Time portable gas detector with 3 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

LC-1112-A-000-1
(2913)

INTEC  LC-1112-A-000-1

Intec Controls PolyGard LC-1112 V3 Analog Gas Transmitter for Carbon Monoxide (CO) 0-150 / 0-200 / 0-250 / 0-300 ppm. 1 4-20mA & 2-10V analog output. Wall mounted. NEMA 4X Enclosure. UL Listed and CSA Certified.

Configure

$327.00 
BWS1-ML-Y
(6383)

BW  BWS1-ML-Y

BW Solo Serviceable Single-gas Detector for Carbon Monoxide (CO) 0-2000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-4424
(6802)

PROSENSE  PC3-4424

Prosense PC3-4424 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$463.32 
CM-6
(637)

MACURCO  CM-6

MACURCO CM-6 low voltage gas detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1. Optional LADBS approval.

Configure

$481.90 
CM-12
(3415)

MACURCO  CM-12

MACURCO CM-12 line voltage Gas Detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$494.01 
P-4434
(6777)

PROSENSE  P-4434

Prosense P-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm to 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
364-455-01-365-796-110100
(6150)

DELPHIAN  364-455-01-365-796-110100

Delphian GazTell Fixed Point Electrochemical Gas Detector for Carbon Monoxide (CO) 0-100, 0-300 or 0-1000 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

SPSTAXC1
(1477)

HONEYWELL  SPSTAXC1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Carbon Monoxide (CO) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-200 ppm, 0-500 ppm)

Configure

$719.15 
PQN-4434-1/2
(6949)

PROSENSE  PQN-4434-1/2

Prosense PQN-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
OI-6000-EC-CO-X-R_-DC-C
(6832)

OTIS  OI-6000-EC-CO-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Carbon Monoxide (CO) 0-1000ppm. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

PQD-4434-1/2
(6738)

PROSENSE  PQD-4434-1/2

Prosense PQD-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$875.16 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.