Gds C2-20-014-19/00-000-00/0-0-0-0-0/0-0 | Hydrogen | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   C2-20-014-19/00-000-00/0-0-0-0-0/0-0

GDS C2-20-014-19/00-000-00/0-0-0-0-0/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Hydrogen (H2) sensor with range 0-1% or 0-4% vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

Inquiry



The C2 Protector Display & Alarm Controller provides signal conditioning, display and alarm functions for one or two critical input variables.

Versatile

Designed to provide low-cost direct monitoring for one or two gas sensors or flame detectors, the C2 Protector controller offers a highly-integrated, complete solution for detection of hazardous conditions. Versatile input signal conditioning options allow direct connection of any GDS Corp electrochemical sensor, and local or remote support for any GDS Corp combustible, PID or infrared sensor. Both channels can be configured to accept analog inputs from sources such as the GDS-49 Sensor Transmitter, GDS-IR Point Infrared Gas Detector or any standard 4-20mA source.

Additional C2 options include 5A SPDT discrete relays, 4-20mA outputs, light stacks and audible annunciators.

One popular application for the C2 is as a dual gas detector equipped with one local combustible sensor and one local toxic sensor. Alternatively, two combustible locations may be monitored with one sensor local and another remote.

Real-Time Display

A large graphic LCD screen displays input data as calibrated engineering units, bargraphs or 30-minute trends. Three adjustable alarm levels per channel, combined with programmable relays with voting logic allows flexible control of beacons, horns and other warning devices. Highly visible red and yellow LEDs visually indicate alarm status at all times.

Digitally Connected

An optional RS-485 MODBUS® slave port allows multiple C2 controllers to be multi-dropped on a single data highway. The C2 Protector controller is also 100% compatible with the ProtectorHMI Visualization and Historian software that can monitor, display and record data from up to ten C1 Protector or C2 Protector controllers.

Reliability

The C2 Protector controller is CSA certified to CSA C22.2 No. 152 for combustibles and Class I, Division 2, Groups A, B, C, D for use in hazardous areas. An optional NEMA 7 enclosure allows use in Class I Div 1 areas. Up to twelve watts of 24 VDC power is available for auxiliary devices or transmitters.

FEATURES

  • Accepts one or two direct-connect local or remote sensors or 4-20mA
  • Large LCD display shows values, bar-graph and trend data
  • Two programmable 5A SPDT common relays for Alarm 1, Alarm 2, Horn or FAULT
  • Optional 6x relay board for perchannel SPDT contacts
  • Optional dual channel 4-20mA board for current loop output
  • Operates on either +24VDC or 117/240VAC 50/60Hz
  • ACK button silences HORN without affecting alarm relays
  • Relay voting logic reduces need for external hardware
  • Touch and magnetic keys for non-intrusive operation in XP areas
  • Pushbutton zero and span calibra tion for directly connected sensors
  • NEMA 4x approved for Class 1 Div 2 area without purge
  • MODBUS® slave port for easy interface from master devices
  • CSA certified to C22.2 No 152 for combustible gas detection and approved for Class 1, Div 2 Groups A, B, C, D
  • Manufactured in USA

C2 Protector SPECIFICATIONS
Power Input: 24VDC (12 Watt MAX) 85-240 VAC power supply included
Display Backlit 128x64 pixel LCD shows trend, bargraph and engineering units; flashing alarm LEDs indicate alarm status
Input Inputs available for dual catalytic bead LEL, dual toxic / O2, one each catalytic bead & toxic / O2, and dual 4-20mA
MODBUS I/O Optional slave mode RS-232 or RS-485 MODBUS interface
Relay Output Two common output relays configurable for A1, A2, FAIL & HORN ; 5A @ 30VDC / 240VAC resistive load
Analog Output Optional dual channel 4-20mA current loop. Max loop R is 800 ohms with nominal 24VDC
Audible Output Optional 100db alarm (NEMA 4X only)
Temp -25°C to +50°C operating
Housing NEMA 4X approved for Class 1 Div 2 Groups A, B, C, D
NEMA 7 wall-mount approved for Cls 1 Div 1 Groups B, C, D
Dimensions NEMA 4X Non-metallic: 11.25” x 13.31” x 7.25” (w-h-d)
NEMA 4X Painted or stainless: 9.84” x 13.65” x 6.2”
NEMA 7: 13” x 14.25” x 6.25”
Approvals CSA C22.2 No. 1010.1 & 152 for combustibles & ISA S82.02;
UL 1604 / C22.2 No 213 (NEMA 4X = Div 2 Groups A, B, C, D;
NEMA 7 = Div 1 Groups B, C, D) EN55011 & EN61000 (CE Mark)
Warranty 2 years from date of purchase on electronics
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
CYL-10314080
(1286)

PORTAGAS  CYL-10314080

Calibration Gas Hydrogen (H2), 100 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
1200-0545
(3175)

GDS  1200-0545

GDS Gas Detector Calibration Gas Cylinder Hydrogen (H2) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

10-0221/DUAL
(435)

RC SYSTEMS  10-0221/DUAL

RC Systems 4-20 mA 2-channel analog input board for ST-90 Dual Controllers



$268.83 
1200-0511
(3105)

GDS  1200-0511

GDS Gas Detector Calibration Gas Kit Hydrogen (H2) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

> HYDROGEN :    24 Items found.
M001-0019-000
(6329)

MPOWER  M001-0019-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen (H2) 0-1000ppm or 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$278.40 
P-3634
(6776)

PROSENSE  P-3634

Prosense P-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
PQN-3634-1/2
(6948)

PROSENSE  PQN-3634-1/2

Prosense PQN-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
BWS1-R-Y
(6387)

BW  BWS1-R-Y

BW Solo Serviceable Single-gas Detector for Hydrogen (H2) 0-1000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PQD-3634-1/2
(6737)

PROSENSE  PQD-3634-1/2

Prosense PQD-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$875.16 
SPSTAXG1
(1487)

HONEYWELL  SPSTAXG1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen (H2) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-1000 ppm, 0-10000 ppm)

Configure

$929.07 
GG-H2-EC-2000
(2965)

CALIBRATION TECHNOLOGIES  GG-H2-EC-2000

CTI GasGuard H2 Hydrogen Catalytic Bead Sensor 0-1% (10000 ppm or 25%LEL) for gas leak detection in battery charging rooms, steel industry, refineries and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
2106B1416
(1462)

HONEYWELL  2106B1416

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen (H2) (0-1000 ppm to 0-10000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
GG-H2-EC-10000-EXP
(5978)

CALIBRATION TECHNOLOGIES  GG-H2-EC-10000-EXP

CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
100-0008-SS/100-0015-H2
(4753)

ESP SAFETY  100-0008-SS/100-0015-H2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Hydrogen (H2) 0-4% vol or 0-100ppm (Catalytic bead or electrochemical). Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
SPXCDULNG1
(665)

HONEYWELL  SPXCDULNG1

Honeywell XCD Sensepoint Gas Detector, Hydrogen (H2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen (H2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 1,000ppm only. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,566.91 
961-070026-01PG
(6053)

DETCON  961-070026-01PG

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

961-840026-100G
(6363)

DETCON  961-840026-100G

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

S3KUL2-XNXXSG1SS
(689)

HONEYWELL  S3KUL2-XNXXSG1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN (H2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-1,000ppm ,0-10,000ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,806.92 
SPXCDULNG2
(5102)

HONEYWELL  SPXCDULNG2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen (H2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 1000 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
2100AL-0-1018/0500P/L0
(120)

RC SYSTEMS  2100AL-0-1018/0500P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$2,003.89 
41001AL-0-1019/0500P/L0
(7163)

RC SYSTEMS  41001AL-0-1019/0500P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$2,025.97 
51001AL-0-1019/0500P/L0
(7126)

RC SYSTEMS  51001AL-0-1019/0500P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$2,081.82 
31001AL-0-9018/2000P/L0
(5782)

RC SYSTEMS  31001AL-0-9018/2000P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
XNXUTAENNNNN-XNXXSG1SS
(839)

HONEYWELL  XNXUTAENNNNN-XNXXSG1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen (H2) compatible with all Honeywell gas sensing technologieswith aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-1000ppm, 0-10000ppm

Configure

$2,221.73 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.