Ams A001694 | Oxygen | Probes | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

AMS   A001694

AMS A001694
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
AMS 3211-500 Standard In-Line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Stainless steel tube. IP65. Max temp: 550 °C.

A001694   
Please Email us your request for quote   

Back Purge
For cleaning of the filter with heavy dust for use in Ex-free Zone
Pneumatic Unit
GFC Housing with window with built-in: Pressure reduction for reference air, Flowmeter with needle valve for reference air / cal. Gas, valves for manual actuation between the gases
Pneumatic Unit
GFC Housing with window with built-in: Pressure reduction for reference air, Flowmeter with needle valve for reference air / cal. Gas, valves for manual actuation between the gases

   4 Weeks  ]


The Application:

The Standard In-Line Flue gas probe AMS 3211-500 is equipped with a Zircon dioxide sensor located in the tip of the probe. The Flue gas probe AMS 3211-500 can be used for the measurement of Oxygen in flue gases from gaseous, liquid and solid fuels and biomass. In Applications with solid fuels and biomass the Standard In-Line Flue gas probe AMS 3211-500 is equipped with an additional Stainless steel tube to protect the probe against abrasion. In combination with the Transmitter AMS 3220 the Standard In-Line Flue gas probe AMS 3211-500 is certified by the German TÜV according European and German environmental regulations and fulfils the requirements for QAL 1 according EN 14181 and EN ISO 14956.

The Measuring principle:

All AMS Flue gas probes are equipped with Zircon dioxide sensors with Platinum electrodes which distinguish themselves by a long lifetime in the process. The location of the Zircon dioxide sensor at the tip of the probe guarantee extremely fast responses of the Standard In-Line Flue gas probe AMS 3211-500. The Transmitters AMS 3220 and AMS 5200 supply the current for the heater in the Zircon dioxide sensor. To increase the stability of the measuring values, the sensor temperature is regulated within low limits. Simultaneously the Transmitters AMS 3220 and AMS 5200 m

The Measuring system:

Typically continuous Oxygen measuring systems are consisting of a Flue gas probe with built in Zircon dioxide sensor, a Transmitter and a Pneumatic unit. The Pneumatic unit supplies continuously instrument air to the Zircon dioxide sensor which serves as Reference air. Via a second gas inlet port at the probe flange the Zircon dioxide sensor can be supplied with calibration gas to verify and correct the calibration of the sensor in regular intervals. The Pneumatic unit and the Flue gas probe are connected by two high pressure pneumatic hoses. A multi wire, protected cable connects the Transmitter to the Flue gas probe electronically. Due to the modular construction of the Oxygen measuring systems of AMS the Transmitter can be installed inside the housing of the Pneumatic unit. This reduces the required length of both high pressure pneumatic hose and protected cable. The power supply for the Transmitter and the Flue gas probe is also installed in the GRP-housing of the Pneumatic unit. The flue gas probe, the Transmitter and the Pneumatic unit are manufactured according to the protection class IP 65 for General Applications. The Standard In-Line Flue gas probe AMS 3211-500 is for universal use. For applications with corrosive flue gases all gas wetted parts of the probe are manufactured from Inconel 600. To replace an already existing continuous oxygen measuring system the Standard In-Line Flue gas probe AMS 3211-500 can be fitted with all flange sizes both in DIN and ANSI dimensions.

Optional the Standard In-Line Flue gas probe AMS 3211-500 can be equipped with time controlled back purge for high dust applications and with Auto-calibration for the automatic, time controlled calibration.

AMS 3211-500
Measuring principle ZrO2 sensor with Pt-electrodes
Application Residual oxygen in flue gas
Construction ZrO2 sensor installed in the tip of the probe with stainless steel sintermetalfilter screwed on
Flue gas temp., max. ≤ 500 °C, shorttime to 550 °C
Dust content (flue gas) max. 5 Gram/Nm3, if higher shield to protect against abrasion or separate protecting tube
Flue gas velocity max. 20 m/Sec., if higher shield to protect against abrasion or separate protecting tube
Time for pre-heating ~ 10 Minutes
T90-Time < 20 Seconds
Reaction time < 2 Seconds
Probe length 150 – 3000 mm
Connecting flanges DN 65 PN 16, DN 80 PN 16 (larger on request)
Material Stainless steel 1.4541, Inconel 600
Installation in the stack pointing downward
Protection IP 65
Reference air supply by separate pneumatic unit
Calibration gas supply by separate pneumatic unit
Weight ca. 6,5 kg
Accessories Transmitter: AMS 5200 / AMS 3220 in housing IP 65
Pneumatic unit: GRP housing, Dimensions: 600 x 600 x 200 mm / 800 x 600 x 300 mm. Back-purge, Auto-calibration

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
A000154
(2774)

AMS  A000154

AMS 5200 CEMS Analyzer Transmitter for control, monitoring and supply of AMS Flue Gas Probes for O2 (Oxygen) 0-25% Vol. and COe RS232 serial interface. 4-20mA and 0-10V outputs, 2 alarm and 1 status relays. IP65 housing. Optional Pneumatic unit and Ex-d housing for use in Ex-Zone 1 or 2. Compatible Probes: AMS 3211-000 / 500 / 600 / 700 / 860 Ex. Power 110/ 240 VAC, 50/60 Hz or 24 VDC.

> OXYGEN :    4 Items found.
A000249
(2954)

AMS  A000249

AMS 3211-000 ZrO2 installed into flow through cell for installation in EExp Control Cabinet by costumer Electrical connection; Flying Leads without terminal Box

A001700
(2776)

AMS  A001700

AMS 3211-600 High temperature Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Ceramics, Kanthal tube. IP65. Max temp: 1700 °C.

A000352
(2916)

AMS  A000352

AMS 3211-700 High temperature Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Kanthal tube. IP65. Max temp: 1400 °C.

A000636
(2917)

AMS  A000636

AMS 3211-860-150 In-line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Stainless Steel tube. IP65. Max temp: 500 °C. Ex Zone1 or Ex Zone 2.

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.