Ams A000154 | Oxygen+co | Analyzers | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

AMS   A000154

AMS A000154
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
AMS 5200 CEMS Analyzer Transmitter for control, monitoring and supply of AMS Flue Gas Probes for O2 (Oxygen) 0-25% Vol. and COe RS232 serial interface. 4-20mA and 0-10V outputs, 2 alarm and 1 status relays. IP65 housing. Optional Pneumatic unit and Ex-d housing for use in Ex-Zone 1 or 2. Compatible Probes: AMS 3211-000 / 500 / 600 / 700 / 860 Ex. Power 110/ 240 VAC, 50/60 Hz or 24 VDC.

A000154   
Please Email us your request for quote   

Housing
Power Supply
Measuring Ranges
Digital signalling of active range
Automatic calibration
For use in Ex-free Zone
Fuel Gas Probes
Pneumatic Unit

 4 Weeks  ]


Application:

The Transmitter AMS 5200 is the control, evaluation- and supply unit for all AMS Flue gas probes. The transmitter AMS 5200 is in preparation for QAL 1 - certification according European and German Environmental Regulations.

Measuring principle:

The AMS Flue gas probes are equipped with Zircon dioxide sensors with Platinum electrodes which are known for their long life expectancy. The Transmitter AMS 5200 supplies the current for the heater of the Zircon dioxide sensor. To increase the stability of the measuring values AMS regulates the temperature of the Zircon dioxide sensor within tight limits. The Transmitter AMS 5200 monitors continuously the Zircon dioxide sensor in the AMS flue gas probes for accuracy and plausibility.

Measuring system:

Typically the Transmitter AMS 5200 is mounted into the GRP housing of the pneumatic unit. The Transmitter AMS 5200 is mounted into a wall mounting housing with protection class IP 65 for General applications. For installations in Ex Zone 1 classified areas the Transmitter AMS 5200 is also available in an Ex-d certified housing.

The Transmitter AMS 5200 could be mounted in an optional pneumatic unit. Due to a 5-wire protected cable the Transmitter AMS 5200 is connected to the flue gas probe.Via the cable the probe is supplied with current for the heater of the Zircon dioxide sensor. Another wire transfers the measuring signals of the probe to the Transmitter AMS 5200 for evaluation. The display of the Transmitter shows the actual measuring values, the status signals and other important values such as heater current, offset and possible errors. The oxygen value is provided for further transmission via the potential free analogue signal port and via the digital RS 232 interface. The other values are available via potential free contacts. The calibration of the Zircon dioxide sensor in the flue gas probe can be accessed in the main menu of the Transmitter AMS 5200. During a calibration the analogue signal is “frozen” to the last valid measuring value. The status signal indicates “maintenance”. For use with the O2 / COe-Flue gas probe the Transmitter AMS 5200 is available as Twin-Version and provides separate measuring signals for the components O2 and COe.

AMS 5200 Transmitter Technical Data
Measuring principle ZrO2 sensor with Pt-electrodes
Application Soldering machines
OEM application
Gases Industries
Chemical Industries
Probes AMS 3211-000 / 500 / 600 / 700 / 860 Ex
Measuring range 0 ... 25 Vol%
Analogue signal port (0) 4 ... 20 mA or 0 ... 10V, galvanically separated
Reproducability +/- 2 % of the measuring value
Resolution 0,01 %
T90-Time ca. 20 Seconds
Display 2* 20 digit, illuminated LCD display
1. Line: display of concentration in ppm or Vol %
2. Line: messages, device status, sensor parameters
Messages 1 System message (measuring value yes / no) max. 2 messages configurable as oxygen value, calibration message, measuring value in the range, flow rate
Digital communication serial interface RS232
Ambient operation temp. + 5 °C up to + 60 °C
Power supply 24 / 110 / 230 VAC
Protection / Housing / Dimensions IP65 / wall mounting housing / ca. 300 x 320 x 130 mm (hxbxd)
Ex-d housing for Zone 1 / ca. 300 x 250 x 200 mm (hxbxt)
Weight 2.5 kg
Options pneumatic unit for supplying the probes with reference gas and / or calibration gas
automatic calibration by using a pneumatic unit

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    4 Items found.
A001694
(2775)

AMS  A001694

AMS 3211-500 Standard In-Line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Stainless steel tube. IP65. Max temp: 550 °C.

A001700
(2776)

AMS  A001700

AMS 3211-600 High temperature Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Ceramics, Kanthal tube. IP65. Max temp: 1700 °C.

A000352
(2916)

AMS  A000352

AMS 3211-700 High temperature Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Kanthal tube. IP65. Max temp: 1400 °C.

A000636
(2917)

AMS  A000636

AMS 3211-860-150 In-line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2). Stainless Steel tube. IP65. Max temp: 500 °C. Ex Zone1 or Ex Zone 2.

> OXYGEN+CO :    2 Items found.
A002410
(2918)

AMS  A002410

AMS 3211-1500 Standard In-Line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2) and Carbon Monoxide (COe). Stainless steel tube. IP65. Max temp: 400 °C.

A001159
(2919)

AMS  A001159

AMS 3211-1600 High Temperature In-Line Fuel Gas Probe with Zircon dioxide sensor for measurement of Oxygen (O2) and Carbon Monoxide (COe). Ceramics or Kanthal tube. IP65. Max temp: 1100 °C.

Cookie Notice